Literature DB >> 20432292

3D magnetization-prepared imaging using a stack-of-rings trajectory.

Holden H Wu1, Dwight G Nishimura.   

Abstract

Efficient acquisition strategies for magnetization-prepared imaging based on the three-dimensional (3D) stack-of-rings k-space trajectory are presented in this work. The 3D stack-of-rings can be acquired with centric ordering in all three dimensions for greater efficiency in capturing the desired contrast. In addition, the 3D stack-of-rings naturally supports spherical coverage in k-space for shorter scan times while achieving isotropic spatial resolution. While non-Cartesian trajectories generally suffer from greater sensitivity to system imperfections, the 3D stack-of-rings can enhance magnetization-prepared imaging with a high degree of robustness to timing delays and off-resonance effects. As demonstrated with phantom scans, timing errors and gradient delays only cause a bulk rotation of the 3D stack-of-rings reconstruction. Furthermore, each ring can be acquired with a time-efficient retracing design to resolve field inhomogeneities and enable fat/water separation. To demonstrate its effectiveness, the 3D stack-of-rings are considered for the case of inversion-recovery-prepared structural brain imaging. Experimental results show that the 3D stack-of-rings can achieve higher signal-to-noise ratio and higher contrast-to-noise ratio within a shorter scan time when compared to the standard inversion-recovery-prepared sequence based on 3D Cartesian encoding. The design principles used for this specific case of inversion-recovery-prepared brain imaging can be applied to other magnetization-prepared imaging applications. (c) 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20432292      PMCID: PMC2905147          DOI: 10.1002/mrm.22288

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  27 in total

1.  Multicoil Dixon chemical species separation with an iterative least-squares estimation method.

Authors:  Scott B Reeder; Zhifei Wen; Huanzhou Yu; Angel R Pineda; Garry E Gold; Michael Markl; Norbert J Pelc
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

2.  The importance of phase-encoding order in ultra-short TR snapshot MR imaging.

Authors:  A E Holsinger; S J Riederer
Journal:  Magn Reson Med       Date:  1990-12       Impact factor: 4.668

3.  Rapid three-dimensional T1-weighted MR imaging with the MP-RAGE sequence.

Authors:  J P Mugler; J R Brookeman
Journal:  J Magn Reson Imaging       Date:  1991 Sep-Oct       Impact factor: 4.813

4.  Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence.

Authors:  D J Atkinson; R R Edelman
Journal:  Radiology       Date:  1991-02       Impact factor: 11.105

5.  CSF-suppressed T2-weighted three-dimensional MP-RAGE MR imaging.

Authors:  F H Epstein; J P Mugler; W S Cail; J R Brookeman
Journal:  J Magn Reson Imaging       Date:  1995 Jul-Aug       Impact factor: 4.813

6.  Segmented turboFLASH: method for breath-hold MR imaging of the liver with flexible contrast.

Authors:  R R Edelman; B Wallner; A Singer; D J Atkinson; S Saini
Journal:  Radiology       Date:  1990-11       Impact factor: 11.105

7.  Snapshot FLASH MRI. Applications to T1, T2, and chemical-shift imaging.

Authors:  A Haase
Journal:  Magn Reson Med       Date:  1990-01       Impact factor: 4.668

8.  "Black blood" T2-weighted inversion-recovery MR imaging of the heart.

Authors:  O P Simonetti; J P Finn; R D White; G Laub; D A Henry
Journal:  Radiology       Date:  1996-04       Impact factor: 11.105

9.  Optimization of parameter values for complex pulse sequences by simulated annealing: application to 3D MP-RAGE imaging of the brain.

Authors:  F H Epstein; J P Mugler; J R Brookeman
Journal:  Magn Reson Med       Date:  1994-02       Impact factor: 4.668

10.  Comparison of breath-hold T1-weighted MR sequences for imaging of the liver.

Authors:  R C Semelka; A B Willms; M A Brown; E D Brown; J P Finn
Journal:  J Magn Reson Imaging       Date:  1994 Nov-Dec       Impact factor: 4.813

View more
  6 in total

1.  Two-dimensional accelerated MP-RAGE imaging with flexible linear reordering.

Authors:  Daniel Brenner; Rüdiger Stirnberg; Eberhard D Pracht; Tony Stöcker
Journal:  MAGMA       Date:  2014-02-08       Impact factor: 2.310

2.  In vivo three-dimensional molecular imaging with Biosensor Imaging of Redundant Deviation in Shifts (BIRDS) at high spatiotemporal resolution.

Authors:  Daniel Coman; Robin A de Graaf; Douglas L Rothman; Fahmeed Hyder
Journal:  NMR Biomed       Date:  2013-07-24       Impact factor: 4.044

3.  Optimization of magnetization-prepared rapid gradient echo (MP-RAGE) sequence for neonatal brain MRI.

Authors:  Lili He; Jinghua Wang; Zhong-Lin Lu; Beth M Kline-Fath; Nehal A Parikh
Journal:  Pediatr Radiol       Date:  2018-05-02

4.  Three-dimensional magnetization-prepared imaging using a concentric cylinders trajectory.

Authors:  Kie Tae Kwon; Holden H Wu; Taehoon Shin; Tolga Cukur; Michael Lustig; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2013-07-01       Impact factor: 4.668

5.  Single shot three-dimensional pulse sequence for hyperpolarized 13 C MRI.

Authors:  Jiazheng Wang; Alan J Wright; De-En Hu; Richard Hesketh; Kevin M Brindle
Journal:  Magn Reson Med       Date:  2016-02-24       Impact factor: 4.668

6.  Optimizing the magnetization-prepared rapid gradient-echo (MP-RAGE) sequence.

Authors:  Jinghua Wang; Lili He; Hairong Zheng; Zhong-Lin Lu
Journal:  PLoS One       Date:  2014-05-30       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.