Abstract

An optimized MR sequence for structural three-dimensional brain scans is presented, giving good T(1) contrast and excellent white matter/gray matter segmentation. Modification of the usual linear phase encoding order to centric phase encoding restores the contrast loss, which usually occurs after magnetization preparation during the acquisition process when large volumes are imaged. The deleterious effects on the point-spread function are compensated by means of an appropriate k-space filter. RF coil inhomogeneities are corrected by means of shaped excitation pulses. High contrast-to-noise images of the entire brain with 1 mm isotropic resolution can be obtained in 12 min. The contrast-to-noise-ratio is about 100% higher than for sequences based on linear phase encoding. Copyright 2000 Academic Press.

Entities:  

Mesh:

Year:  2000        PMID: 10875908     DOI: 10.1006/nimg.2000.0601

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  79 in total

1.  Anatomically informed basis functions in multisubject studies.

Authors:  Stefan Kiebel; Karl J Friston
Journal:  Hum Brain Mapp       Date:  2002-05       Impact factor: 5.038

2.  T1 and proton density at 7 T in patients with multiple sclerosis: an initial study.

Authors:  Katharine T Bluestein; David Pitt; Michael V Knopp; Petra Schmalbrock
Journal:  Magn Reson Imaging       Date:  2011-09-19       Impact factor: 2.546

3.  Three-dimensional, T1-weighted gradient-echo imaging of the brain with a volumetric interpolated examination.

Authors:  Stephan G Wetzel; Glyn Johnson; Andrew G S Tan; Soonmee Cha; Edmond A Knopp; Vivian S Lee; David Thomasson; Neil M Rofsky
Journal:  AJNR Am J Neuroradiol       Date:  2002 Jun-Jul       Impact factor: 3.825

Review 4.  [Mrt-based morphometry. A current assessment].

Authors:  M Tittgemeyer; D Y von Cramon
Journal:  Nervenarzt       Date:  2004-12       Impact factor: 1.214

Review 5.  Segmentation of human brain using structural MRI.

Authors:  Gunther Helms
Journal:  MAGMA       Date:  2016-01-06       Impact factor: 2.310

6.  Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T.

Authors:  Suwit Saekho; Fernando E Boada; Douglas C Noll; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

7.  Methodological issues relating to in vivo cortical myelography using MRI.

Authors:  Stuart Clare; Holly Bridge
Journal:  Hum Brain Mapp       Date:  2005-12       Impact factor: 5.038

8.  Relationship among neuroimaging indices of cerebral health during normal aging.

Authors:  Peter Kochunov; Paul M Thompson; Thomas R Coyle; Jack L Lancaster; Valeria Kochunov; Donal Royall; Jean-Fransçois Mangin; Denis Rivière; Peter T Fox
Journal:  Hum Brain Mapp       Date:  2008-01       Impact factor: 5.038

9.  T1 weighted brain images at 7 Tesla unbiased for Proton Density, T2* contrast and RF coil receive B1 sensitivity with simultaneous vessel visualization.

Authors:  Pierre-François Van de Moortele; Edwards J Auerbach; Cheryl Olman; Essa Yacoub; Kâmil Uğurbil; Steen Moeller
Journal:  Neuroimage       Date:  2009-02-20       Impact factor: 6.556

10.  Optimization of magnetization-prepared rapid gradient echo (MP-RAGE) sequence for neonatal brain MRI.

Authors:  Lili He; Jinghua Wang; Zhong-Lin Lu; Beth M Kline-Fath; Nehal A Parikh
Journal:  Pediatr Radiol       Date:  2018-05-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.