Literature DB >> 19319903

Spectrally selective B1-insensitive T2 magnetization preparation sequence.

Reza Nezafat1, Ronald Ouwerkerk, Andrew J Derbyshire, Matthias Stuber, Elliot R McVeigh.   

Abstract

A T(2) magnetization-preparation (T(2) Prep) sequence is proposed that is insensitive to B(1) field variations and simultaneously provides fat suppression without any further increase in specific absorption rate (SAR). Increased B(1) inhomogeneity at higher magnetic field strength (B(0) > or = 3T) necessitates a preparation sequence that is less sensitive to B(1) variations. For the proposed technique, T(2) weighting in the image is achieved using a segmented B(1)-insensitive rotation (BIR-4) adiabatic pulse by inserting two equally long delays, one after the initial reverse adiabatic half passage (AHP), and the other before the final AHP segment of a BIR-4 pulse. This sequence yields T(2) weighting with both B(1) and B(0) insensitivity. To simultaneously suppress fat signal (at the cost of B(0) insensitivity), the second delay is prolonged so that fat accumulates additional phase due to its chemical shift. Numerical simulations as well as phantom and in vivo image acquisitions were performed to show the efficacy of the proposed technique.

Entities:  

Mesh:

Year:  2009        PMID: 19319903     DOI: 10.1002/mrm.21742

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  21 in total

1.  Venous oxygenation mapping using velocity-selective excitation and arterial nulling.

Authors:  Jia Guo; Eric C Wong
Journal:  Magn Reson Med       Date:  2012-01-31       Impact factor: 4.668

2.  Black-blood native T1 mapping: Blood signal suppression for reduced partial voluming in the myocardium.

Authors:  Sebastian Weingärtner; Nadja M Meßner; Frank G Zöllner; Mehmet Akçakaya; Lothar R Schad
Journal:  Magn Reson Med       Date:  2016-09-16       Impact factor: 4.668

3.  Improved Brachial Plexus Visualization Using an Adiabatic iMSDE-Prepared STIR 3D TSE.

Authors:  Elisabeth Klupp; Barbara Cervantes; Nico Sollmann; Franziska Treibel; Dominik Weidlich; Thomas Baum; Ernst J Rummeny; Claus Zimmer; Jan S Kirschke; Dimitrios C Karampinos
Journal:  Clin Neuroradiol       Date:  2018-07-23       Impact factor: 3.649

4.  Combined T2 -preparation and multidimensional outer volume suppression for coronary artery imaging with 3D cones trajectories.

Authors:  David Y Zeng; Corey A Baron; Mario O Malavé; Adam B Kerr; Phillip C Yang; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2019-11-05       Impact factor: 4.668

5.  Magnetization-prepared IDEAL bSSFP: a flow-independent technique for noncontrast-enhanced peripheral angiography.

Authors:  Tolga Cukur; Ann Shimakawa; Huanzhou Yu; Brian A Hargreaves; Bob S Hu; Dwight G Nishimura; Jean H Brittain
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

6.  Shuffled magnetization-prepared multicontrast rapid gradient-echo imaging.

Authors:  Peng Cao; Xucheng Zhu; Shuyu Tang; Andrew Leynes; Angela Jakary; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2017-10-27       Impact factor: 4.668

7.  Accelerated contrast-enhanced whole-heart coronary MRI using low-dimensional-structure self-learning and thresholding.

Authors:  Mehmet Akçakaya; Tamer A Basha; Raymond H Chan; Hussein Rayatzadeh; Kraig V Kissinger; Beth Goddu; Lois A Goepfert; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-03-05       Impact factor: 4.668

8.  Slice-selective adiabatic magnetization T2 -preparation (SAMPA) for efficient T2 -weighted imaging at ultrahigh field strengths.

Authors:  Hadrien Dyvorne; Priti Balchandani
Journal:  Magn Reson Med       Date:  2015-12-01       Impact factor: 4.668

9.  Accelerated isotropic sub-millimeter whole-heart coronary MRI: compressed sensing versus parallel imaging.

Authors:  Mehmet Akçakaya; Tamer A Basha; Raymond H Chan; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

10.  Motion and flow insensitive adiabatic T2 -preparation module for cardiac MR imaging at 3 Tesla.

Authors:  Elizabeth R Jenista; Wolfgang G Rehwald; Enn-Ling Chen; Han W Kim; Igor Klem; Michele A Parker; Raymond J Kim
Journal:  Magn Reson Med       Date:  2012-12-04       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.