Literature DB >> 23750177

Energy and coincidence time resolution measurements of CdTe detectors for PET.

G Ariño1, M Chmeissani, G De Lorenzo, C Puigdengoles, E Cabruja, Y Calderón, M Kolstein, J G Macias-Montero, R Martinez, E Mikhaylova, D Uzun.   

Abstract

We report on the characterization of 2 mm thick CdTe diode detector with Schottky contacts to be employed in a novel conceptual design of PET scanner. Results at -8°C with an applied bias voltage of -1000 V/mm show a 1.2% FWHM energy resolution at 511 keV. Coincidence time resolution has been measured by triggering on the preamplifier output signal to improve the timing resolution of the detector. Results at the same bias and temperature conditions show a FWHM of 6 ns with a minimum acceptance energy of 500 keV. These results show that pixelated CdTe Schottky diode is an excellent candidate for the development of next generation nuclear medical imaging devices such as PET, Compton gamma cameras, and especially PET-MRI hybrid systems when used in a magnetic field immune configuration.

Entities:  

Keywords:  Gamma detectors (scintillators, CZT, HPG, HgI etc); Solid state detectors; Spectrometers; Timing detectors

Year:  2013        PMID: 23750177      PMCID: PMC3672966          DOI: 10.1088/1748-0221/8/02/C02015

Source DB:  PubMed          Journal:  J Instrum        ISSN: 1748-0221            Impact factor:   1.415


  1 in total

1.  Performance of a brain PET camera based on anger-logic gadolinium oxyorthosilicate detectors.

Authors:  Joel S Karp; Suleman Surti; Margaret E Daube-Witherspoon; Richard Freifelder; Christopher A Cardi; Lars-Eric Adam; Kilian Bilger; Gerd Muehllehner
Journal:  J Nucl Med       Date:  2003-08       Impact factor: 10.057

  1 in total
  11 in total

Review 1.  Innovations in Instrumentation for Positron Emission Tomography.

Authors:  Eric Berg; Simon R Cherry
Journal:  Semin Nucl Med       Date:  2018-03-12       Impact factor: 4.446

2.  Towards time-of-flight PET with a semiconductor detector.

Authors:  Gerard Ariño-Estrada; Gregory S Mitchell; Sun Il Kwon; Junwei Du; Hadong Kim; Leonard J Cirignano; Kanai S Shah; Simon R Cherry
Journal:  Phys Med Biol       Date:  2018-02-16       Impact factor: 3.609

3.  First Cerenkov charge-induction (CCI) TlBr detector for TOF-PET and proton range verification.

Authors:  Gerard Ariño-Estrada; Gregory S Mitchell; Hadong Kim; Junwei Du; Sun Il Kwon; Leonard J Cirignano; Kanai S Shah; Simon R Cherry
Journal:  Phys Med Biol       Date:  2019-08-28       Impact factor: 3.609

4.  Hybrid Pixel-Waveform (HPWF) Enabled CdTe Detectors for Small Animal Gamma-Ray Imaging Applications.

Authors:  A Groll; K Kim; H Bhatia; J C Zhang; J H Wang; Z M Shen; L Cai; J Dutta; Q Li; L J Meng
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2016-11-01

5.  Development of TlBr detectors for PET imaging.

Authors:  Gerard Ariño-Estrada; Junwei Du; Hadong Kim; Leonard J Cirignano; Kanai S Shah; Simon R Cherry; Gregory S Mitchell
Journal:  Phys Med Biol       Date:  2018-07-03       Impact factor: 3.609

6.  Simulation and evaluation of a high resolution VIP PEM system with a dedicated LM-OSEM algorithm.

Authors:  D Uzun; G De Lorenzo; M Kolstein; M Chmeissani
Journal:  J Instrum       Date:  2014-05-12       Impact factor: 1.415

7.  Simulation of the expected performance of a seamless scanner for brain PET based on highly pixelated CdTe detectors.

Authors:  Ekaterina Mikhaylova; Gianluca De Lorenzo; Mokhtar Chmeissani; Machiel Kolstein; Mario Cañadas; Pedro Arce; Yonatan Calderón; Dilber Uzun; Gerard Ariño; José Gabriel Macias-Montero; Ricardo Martinez; Carles Puigdengoles; Enric Cabruja
Journal:  IEEE Trans Med Imaging       Date:  2013-10-04       Impact factor: 10.048

8.  Pixelated CdTe detectors to overcome intrinsic limitations of crystal based positron emission mammographs.

Authors:  G De Lorenzo; M Chmeissani; D Uzun; M Kolstein; I Ozsahin; E Mikhaylova; P Arce; M Cañadas; G Ariño; Y Calderón
Journal:  J Instrum       Date:  2013-01       Impact factor: 1.415

9.  Evaluation of Compton gamma camera prototype based on pixelated CdTe detectors.

Authors:  Y Calderón; M Chmeissani; M Kolstein; G De Lorenzo
Journal:  J Instrum       Date:  2014-06       Impact factor: 1.415

10.  Optimization, evaluation, and comparison of standard algorithms for image reconstruction with the VIP-PET.

Authors:  E Mikhaylova; M Kolstein; G De Lorenzo; M Chmeissani
Journal:  J Instrum       Date:  2014-07       Impact factor: 1.415

View more