Reproducibility of intensity-based estimates of lung ventilation.

Kaifang Du1, John E Bayouth, Kai Ding, Gary E Christensen, Kunlin Cao, Joseph M Reinhardt.   

Abstract

PURPOSE: Lung function depends on lung expansion and contraction during the respiratory cycle. Respiratory-gated CT imaging and image registration can be used to estimate the regional lung volume change by observing CT voxel density changes during inspiration or expiration. In this study, the authors examine the reproducibility of intensity-based estimates of lung tissue expansion and contraction in three mechanically ventilated sheep and ten spontaneously breathing humans. The intensity-based estimates are compared to the estimates of lung function derived from image registration deformation field.
METHODS: 4DCT data set was acquired for a cohort of spontaneously breathing humans and anesthetized and mechanically ventilated sheep. For each subject, two 4DCT scans were performed with a short time interval between acquisitions. From each 4DCT data set, an image pair consisting of a volume reconstructed near end inspiration and a volume reconstructed near end exhalation was selected. The end inspiration and end exhalation images were registered using a tissue volume preserving deformable registration algorithm. The CT density change in the registered image pair was used to compute intensity-based specific air volume change (SAC) and the intensity-based Jacobian (IJAC), while the transformation-based Jacobian (TJAC) was computed directly from the image registration deformation field. IJAC is introduced to make the intensity-based and transformation-based methods comparable since SAC and Jacobian may not be associated with the same physiological phenomenon and have different units. Scan-to-scan variations in respiratory effort were corrected using a global scaling factor for normalization. A gamma index metric was introduced to quantify voxel-by-voxel reproducibility considering both differences in ventilation and distance between matching voxels. The authors also tested how different CT prefiltering levels affected intensity-based ventilation reproducibility.
RESULTS: Higher reproducibility was found for anesthetized mechanically ventilated animals than for the humans for both the intensity-based (IJAC) and transformation-based (TJAC) ventilation estimates. The human IJAC maps had scan-to-scan correlation coefficients of 0.45 ± 0.14, a gamma pass rate 70 ± 8 without normalization and 75 ± 5 with normalization. The human TJAC maps had correlation coefficients 0.81 ± 0.10, a gamma pass rate 86 ± 11 without normalization and 93 ± 4 with normalization. The gamma pass rate and correlation coefficient of the IJAC maps gradually increased with increased smoothing, but were still much lower than those of the TJAC maps.
CONCLUSIONS: The transformation-based ventilation maps show better reproducibility than the intensity-based maps, especially in human subjects. Reproducibility was also found to depend on variations in respiratory effort; all techniques were better when applied to images from mechanically ventilated sheep compared to spontaneously breathing human subjects. Nevertheless, intensity-based techniques applied to mechanically ventilated sheep were less reproducible than the transformation-based applied to spontaneously breathing humans, suggesting the method used to determine ventilation maps is important. Prefiltering of the CT images may help to improve the reproducibility of the intensity-based ventilation estimates, but even with filtering the reproducibility of the intensity-based ventilation estimates is not as good as that of transformation-based ventilation estimates.

Entities:  

Mesh:

Year:  2013        PMID: 23718615      PMCID: PMC3676396          DOI: 10.1118/1.4805106

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  31 in total

1.  Subsecond multisection CT of regional pulmonary ventilation.

Authors:  Jehangir K Tajik; Deokiee Chon; Chulho Won; Binh Q Tran; Eric A Hoffman
Journal:  Acad Radiol       Date:  2002-02       Impact factor: 3.173

2.  Distribution of pulmonary ventilation using Xe-enhanced computed tomography in prone and supine dogs.

Authors:  C Marcucci; D Nyhan; B A Simon
Journal:  J Appl Physiol (1985)       Date:  2001-02

Review 3.  MRI of the lungs using hyperpolarized noble gases.

Authors:  Harald E Möller; X Josette Chen; Brian Saam; Klaus D Hagspiel; G Allan Johnson; Talissa A Altes; Eduard E de Lange; Hans-Ulrich Kauczor
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

Review 4.  Technical and analytical advances in pulmonary ventilation SPECT with xenon-133 gas and Tc-99m-Technegas.

Authors:  Kazuyoshi Suga
Journal:  Ann Nucl Med       Date:  2002-07       Impact factor: 2.668

5.  Ventilation from four-dimensional computed tomography: density versus Jacobian methods.

Authors:  Richard Castillo; Edward Castillo; Josue Martinez; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2010-07-30       Impact factor: 3.609

6.  4DCT-based measurement of changes in pulmonary function following a course of radiation therapy.

Authors:  Kai Ding; John E Bayouth; John M Buatti; Gary E Christensen; Joseph M Reinhardt
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

7.  Comparison of image registration based measures of regional lung ventilation from dynamic spiral CT with Xe-CT.

Authors:  Kai Ding; Kunlin Cao; Matthew K Fuld; Kaifang Du; Gary E Christensen; Eric A Hoffman; Joseph M Reinhardt
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

8.  Reproducibility of registration-based measures of lung tissue expansion.

Authors:  Kaifang Du; John E Bayouth; Kunlin Cao; Gary E Christensen; Kai Ding; Joseph M Reinhardt
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

9.  Reproducibility of four-dimensional computed tomography-based lung ventilation imaging.

Authors:  Tokihiro Yamamoto; Sven Kabus; Jens von Berg; Cristian Lorenz; Melody P Chung; Julian C Hong; Billy W Loo; Paul J Keall
Journal:  Acad Radiol       Date:  2012-09-10       Impact factor: 3.173

10.  Performance evaluation of an 85-cm-bore X-ray computed tomography scanner designed for radiation oncology and comparison with current diagnostic CT scanners.

Authors:  Jose L Garcia-Ramirez; Sasa Mutic; James F Dempsey; Daniel A Low; James A Purdy
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-03-15       Impact factor: 7.038

View more
  9 in total

1.  The VAMPIRE challenge: A multi-institutional validation study of CT ventilation imaging.

Authors:  John Kipritidis; Bilal A Tahir; Guillaume Cazoulat; Michael S Hofman; Shankar Siva; Jason Callahan; Nicholas Hardcastle; Tokihiro Yamamoto; Gary E Christensen; Joseph M Reinhardt; Noriyuki Kadoya; Taylor J Patton; Sarah E Gerard; Isabella Duarte; Ben Archibald-Heeren; Mikel Byrne; Rick Sims; Scott Ramsay; Jeremy T Booth; Enid Eslick; Fiona Hegi-Johnson; Henry C Woodruff; Rob H Ireland; Jim M Wild; Jing Cai; John E Bayouth; Kristy Brock; Paul J Keall
Journal:  Med Phys       Date:  2019-02-01       Impact factor: 4.071

2.  Quantification of regional deformation of the lungs by non-rigid registration of three-dimensional contrast-enhanced magnetic resonance imaging.

Authors:  Jiaxin Shao; Peng Hu
Journal:  Quant Imaging Med Surg       Date:  2017-04

3.  Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements.

Authors:  Kaifang Du; Joseph M Reinhardt; Gary E Christensen; Kai Ding; John E Bayouth
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

4.  Modeling the impact of out-of-phase ventilation on normal lung tissue response to radiation dose.

Authors:  Eric M Wallat; Mattison J Flakus; Antonia E Wuschner; Wei Shao; Gary E Christensen; Joseph M Reinhardt; Andrew M Baschnagel; John E Bayouth
Journal:  Med Phys       Date:  2020-04-13       Impact factor: 4.506

5.  The numerical stability of transformation-based CT ventilation.

Authors:  Edward Castillo; Richard Castillo; Yevgeniy Vinogradskiy; Thomas Guerrero
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-01-05       Impact factor: 2.924

6.  Robust HU-based CT ventilation from an integrated mass conservation formulation.

Authors:  Edward Castillo; Yevgeniy Vinogradskiy; Richard Castillo
Journal:  Med Phys       Date:  2019-09-28       Impact factor: 4.071

7.  Evaluation of the ΔV 4D CT ventilation calculation method using in vivo xenon CT ventilation data and comparison to other methods.

Authors:  Geoffrey G Zhang; Kujtim Latifi; Kaifang Du; Joseph M Reinhardt; Gary E Christensen; Kai Ding; Vladimir Feygelman; Eduardo G Moros
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

8.  Quantifying ventilation change due to radiation therapy using 4DCT Jacobian calculations.

Authors:  Taylor J Patton; Sarah E Gerard; Wei Shao; Gary E Christensen; Joseph M Reinhardt; John E Bayouth
Journal:  Med Phys       Date:  2018-08-31       Impact factor: 4.071

9.  Technical Note: On the spatial correlation between robust CT-ventilation methods and SPECT ventilation.

Authors:  Edward Castillo; Richard Castillo; Yevgeniy Vinogradskiy; Girish Nair; Inga Grills; Thomas Guerrero; Craig Stevens
Journal:  Med Phys       Date:  2020-10-17       Impact factor: 4.071

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.