Literature DB >> 20384264

4DCT-based measurement of changes in pulmonary function following a course of radiation therapy.

Kai Ding1, John E Bayouth, John M Buatti, Gary E Christensen, Joseph M Reinhardt.   

Abstract

PURPOSE: Radiation therapy (RT) for lung cancer is commonly limited to subtherapeutic doses due to unintended toxicity to normal lung tissue. Reducing the frequency of occurrence and magnitude of normal lung function loss may benefit from treatment plans that incorporate the regional lung and radiation dose information. In this article, the authors propose a method that quantitatively measures the regional changes in lung tissue function following a course of radiation therapy by using 4DCT and image registration techniques.
METHODS: 4DCT data sets before and after RT from two subjects are used in this study. Nonlinear 3D image registration is applied to register an image acquired near end inspiration to an image acquired near end expiration to estimate the pulmonary function. The Jacobian of the image registration transformation, indicating local lung expansion or contraction, serves as an index of regional pulmonary function. Approximately 120 annotated vascular bifurcation points are used as landmarks to evaluate registration accuracy. The authors compare regional pulmonary function before and after RT to the planned radiation dose at different locations of the lung.
RESULTS: In all registration pairs, the average landmark distances after registration are on the order of 1 mm. The pulmonary function change as indicated by the Jacobian change ranges from -0.15 to 0.1 in the contralateral lung and -0.22 to 0.23 in the ipsilateral lung for subject A, and ranges from -0.4 to 0.39 in the contralateral lung and -0.25 to 0.5 in the ipsilateral lung for subject B. Both of the subjects show larger range of the increase in the pulmonary function in the ipsilateral lung than the contralateral lung. For lung tissue regions receiving a radiation dose larger than 24 Gy, a decrease in pulmonary function was observed. For regions receiving a radiation dose smaller than 24 Gy, either an increase or a decrease in pulmonary function was observed. The relationship between the pulmonary function change and the radiation dose varies at different locations.
CONCLUSIONS: With the use of 4DCT and image registration techniques, the pulmonary function prior to and following a course of radiation therapy can be measured. In the preliminary application of this approach for two subjects, changes in pulmonary function were observed with a weak correlation between the dose and pulmonary function change. In certain sections of the lung, detected locally compromised pulmonary function may have resulted from radiation injury.

Entities:  

Mesh:

Year:  2010        PMID: 20384264      PMCID: PMC2842288          DOI: 10.1118/1.3312210

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  40 in total

1.  Promising clinical outcome of stereotactic body radiation therapy for patients with inoperable Stage I/II non-small-cell lung cancer.

Authors:  Tingyi Xia; Hongqi Li; Qingxuan Sun; Yingjie Wang; Naibin Fan; Yong Yu; Ping Li; Joe Y Chang
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-06-09       Impact factor: 7.038

Review 2.  Radiation pneumonitis and fibrosis: mechanisms underlying its pathogenesis and implications for future research.

Authors:  Pelagia G Tsoutsou; Michael I Koukourakis
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-12-01       Impact factor: 7.038

Review 3.  Visualizing lung function with positron emission tomography.

Authors:  R Scott Harris; Daniel P Schuster
Journal:  J Appl Physiol (1985)       Date:  2006-10-12

4.  Tracking lung tissue motion and expansion/compression with inverse consistent image registration and spirometry.

Authors:  Gary E Christensen; Joo Hyun Song; Wei Lu; Issam El Naqa; Daniel A Low
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

5.  A methodology for using SPECT to reduce intensity-modulated radiation therapy (IMRT) dose to functioning lung.

Authors:  Sarah M McGuire; Sumin Zhou; Lawrence B Marks; Mark Dewhirst; Fang-Fang Yin; Shiva K Das
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-12-01       Impact factor: 7.038

6.  Acute tumor vascular effects following fractionated radiotherapy in human lung cancer: In vivo whole tumor assessment using volumetric perfusion computed tomography.

Authors:  Quan-Sing Ng; Vicky Goh; Jessica Milner; Anwar R Padhani; Michele I Saunders; Peter J Hoskin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-02-01       Impact factor: 7.038

7.  Multiple fields may offer better esophagus sparing without increased probability of lung toxicity in optimized IMRT of lung tumors.

Authors:  Olivier Chapet; Benedick A Fraass; Randall K Ten Haken
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-05-01       Impact factor: 7.038

8.  Relation between radiation-induced whole lung functional loss and regional structural changes in partial irradiated rat lung.

Authors:  Peter van Luijk; Alena Novakova-Jiresova; Hette Faber; Marloes N J Steneker; Harm H Kampinga; Haarm Meertens; Robert P Coppes
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-04-01       Impact factor: 7.038

9.  Reduction of normal lung irradiation in locally advanced non-small-cell lung cancer patients, using ventilation images for functional avoidance.

Authors:  Brian P Yaremko; Thomas M Guerrero; Josue Noyola-Martinez; Rudy Guerra; David G Lege; Linda T Nguyen; Peter A Balter; James D Cox; Ritsuko Komaki
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-03-29       Impact factor: 7.038

10.  Changes in expression of injury after irradiation of increasing volumes in rat lung.

Authors:  Alena Novakova-Jiresova; Peter van Luijk; Harry van Goor; Harm H Kampinga; Robert P Coppes
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-04-01       Impact factor: 7.038

View more
  36 in total

1.  Lung texture in serial thoracic CT scans: correlation with radiologist-defined severity of acute changes following radiation therapy.

Authors:  Alexandra R Cunliffe; Samuel G Armato; Christopher Straus; Renuka Malik; Hania A Al-Hallaq
Journal:  Phys Med Biol       Date:  2014-08-26       Impact factor: 3.609

2.  Assessment of regional ventilation and deformation using 4D-CT imaging for healthy human lungs during tidal breathing.

Authors:  Nariman Jahani; Sanghun Choi; Jiwoong Choi; Krishna Iyer; Eric A Hoffman; Ching-Long Lin
Journal:  J Appl Physiol (1985)       Date:  2015-08-27

3.  4D CT lung ventilation images are affected by the 4D CT sorting method.

Authors:  Tokihiro Yamamoto; Sven Kabus; Cristian Lorenz; Eric Johnston; Peter G Maxim; Maximilian Diehn; Neville Eclov; Cristian Barquero; Billy W Loo; Paul J Keall
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

4.  Comparison of image registration based measures of regional lung ventilation from dynamic spiral CT with Xe-CT.

Authors:  Kai Ding; Kunlin Cao; Matthew K Fuld; Kaifang Du; Gary E Christensen; Eric A Hoffman; Joseph M Reinhardt
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

5.  Biomechanical deformable image registration of longitudinal lung CT images using vessel information.

Authors:  Guillaume Cazoulat; Dawn Owen; Martha M Matuszak; James M Balter; Kristy K Brock
Journal:  Phys Med Biol       Date:  2016-06-08       Impact factor: 3.609

Review 6.  Image-based biomarkers in clinical practice.

Authors:  John E Bayouth; Thomas L Casavant; Michael M Graham; Milan Sonka; Manickam Muruganandham; John M Buatti
Journal:  Semin Radiat Oncol       Date:  2011-04       Impact factor: 5.934

7.  Reproducibility of registration-based measures of lung tissue expansion.

Authors:  Kaifang Du; John E Bayouth; Kunlin Cao; Gary E Christensen; Kai Ding; Joseph M Reinhardt
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

8.  Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements.

Authors:  Kaifang Du; Joseph M Reinhardt; Gary E Christensen; Kai Ding; John E Bayouth
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

9.  An initial investigation of hyperpolarized gas tagging magnetic resonance imaging in evaluating deformable image registration-based lung ventilation.

Authors:  Taoran Cui; G Wilson Miller; John P Mugler; Gordon D Cates; Jaime F Mata; Eduard E de Lange; Qijie Huang; Talissa A Altes; Fang-Fang Yin; Jing Cai
Journal:  Med Phys       Date:  2018-10-23       Impact factor: 4.071

10.  Reproducibility of intensity-based estimates of lung ventilation.

Authors:  Kaifang Du; John E Bayouth; Kai Ding; Gary E Christensen; Kunlin Cao; Joseph M Reinhardt
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.