Literature DB >> 22380392

Reproducibility of registration-based measures of lung tissue expansion.

Kaifang Du1, John E Bayouth, Kunlin Cao, Gary E Christensen, Kai Ding, Joseph M Reinhardt.   

Abstract

PURPOSE: Lung function depends on lung expansion and contraction during the respiratory cycle. Respiratory-gated CT imaging and 3D image registration can be used to locally estimate lung tissue expansion and contraction (regional lung volume change) by computing the determinant of the Jacobian matrix of the image registration deformation field. In this study, the authors examine the reproducibility of Jacobian-based measures of lung tissue expansion in two repeat 4DCT acquisitions of mechanically ventilated sheep and free-breathing humans.
METHODS: 4DCT image data from three white sheep and nine human subjects were used for this analysis. In each case, two 4DCT studies were acquired for each subject within a short time interval. The animal subjects were anesthetized and mechanically ventilated, while the humans were awake and spontaneously breathing based on respiratory pacing audio cues. From each 4DCT data set, an image pair consisting of a volume reconstructed near end inspiration and a volume reconstructed near end exhalation was selected. The end inspiration and end exhalation images were registered using a tissue volume preserving deformable registration algorithm and the Jacobian of the registration deformation field was used to measure regional lung expansion. The Jacobian map from the baseline data set was compared to the Jacobian map from the followup data by measuring the voxel-by-voxel Jacobian ratio.
RESULTS: In the animal subjects, the mean Jacobian ratio (baseline scan Jacobian divided by followup scan Jacobian, voxel-by-voxel) was 0.9984±0.021 (mean ± standard deviation, averaged over the entire lung region). The mean Jacobian ratio was 1.0224±0.058 in the human subjects. The reproducibility of the Jacobian values was found to be strongly dependent on the reproducibility of the subject's respiratory effort and breathing pattern.
CONCLUSIONS: Lung expansion, a surrogate for lung function, can be assessed using two or more respiratory-gated CT image acquisitions. The results show that good reproducibility can be obtained in anesthetized, mechanically ventilated animals, but variations in respiratory effort and breathing patterns reduce reproducibility in spontaneously-breathing humans. The global linear normalization can globally compensate for breathing effort differences, but a homogeneous scaling does not account for differences in regional lung expansion rates. Additional work is needed to develop compensation procedures or normalization schemes that can account for local variations in lung expansion during respiration.

Entities:  

Mesh:

Year:  2012        PMID: 22380392      PMCID: PMC3306443          DOI: 10.1118/1.3685589

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  29 in total

1.  Distribution of pulmonary ventilation using Xe-enhanced computed tomography in prone and supine dogs.

Authors:  C Marcucci; D Nyhan; B A Simon
Journal:  J Appl Physiol (1985)       Date:  2001-02

Review 2.  MRI of the lungs using hyperpolarized noble gases.

Authors:  Harald E Möller; X Josette Chen; Brian Saam; Klaus D Hagspiel; G Allan Johnson; Talissa A Altes; Eduard E de Lange; Hans-Ulrich Kauczor
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Volume adjustment of lung density by computed tomography scans in patients with emphysema.

Authors:  S B Shaker; A Dirksen; L C Laursen; L T Skovgaard; N H Holstein-Rathlou
Journal:  Acta Radiol       Date:  2004-07       Impact factor: 1.990

Review 4.  Positron emission tomography: theory and its application to the study of lung disease.

Authors:  D P Schuster
Journal:  Am Rev Respir Dis       Date:  1989-03

Review 5.  Functional MRI of the lung using hyperpolarized 3-helium gas.

Authors:  Edwin J R van Beek; Jim M Wild; Hans-Ulrich Kauczor; Wolfgang Schreiber; John P Mugler; Eduard E de Lange
Journal:  J Magn Reson Imaging       Date:  2004-10       Impact factor: 4.813

6.  High-resolution maps of regional ventilation utilizing inhaled fluorescent microspheres.

Authors:  H T Robertson; R W Glenny; D Stanford; L M McInnes; D L Luchtel; D Covert
Journal:  J Appl Physiol (1985)       Date:  1997-03

7.  Estimation of regional pleural surface expansile forces in intact dogs.

Authors:  E A Hoffman; T Behrenbeck; P A Chevalier; E H Wood
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1983-09

8.  Use of weekly 4DCT-based ventilation maps to quantify changes in lung function for patients undergoing radiation therapy.

Authors:  Yevgeniy Y Vinogradskiy; Richard Castillo; Edward Castillo; Adam Chandler; Mary K Martel; Thomas Guerrero
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

9.  Topographical distribution of regional lung volume in anesthetized dogs.

Authors:  R D Hubmayr; B J Walters; P A Chevalier; J R Rodarte; L E Olson
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1983-04

10.  Dynamic radial projection MRI of inhaled hyperpolarized 3He gas.

Authors:  Jim M Wild; Martyn N J Paley; Larry Kasuboski; Andrew Swift; Stan Fichele; Neil Woodhouse; Paul D Griffiths; Edwin J R van Beek
Journal:  Magn Reson Med       Date:  2003-06       Impact factor: 4.668

View more
  25 in total

1.  4D CT lung ventilation images are affected by the 4D CT sorting method.

Authors:  Tokihiro Yamamoto; Sven Kabus; Cristian Lorenz; Eric Johnston; Peter G Maxim; Maximilian Diehn; Neville Eclov; Cristian Barquero; Billy W Loo; Paul J Keall
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

2.  Functional-guided radiotherapy using knowledge-based planning.

Authors:  Austin M Faught; Lindsey Olsen; Leah Schubert; Chad Rusthoven; Edward Castillo; Richard Castillo; Jingjing Zhang; Thomas Guerrero; Moyed Miften; Yevgeniy Vinogradskiy
Journal:  Radiother Oncol       Date:  2018-04-05       Impact factor: 6.280

3.  Clinical validation of 4-dimensional computed tomography ventilation with pulmonary function test data.

Authors:  Douglas Brennan; Leah Schubert; Quentin Diot; Richard Castillo; Edward Castillo; Thomas Guerrero; Mary K Martel; Derek Linderman; Laurie E Gaspar; Moyed Miften; Brian D Kavanagh; Yevgeniy Vinogradskiy
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-03-25       Impact factor: 7.038

Review 4.  Tuberculosis as a three-act play: A new paradigm for the pathogenesis of pulmonary tuberculosis.

Authors:  Robert L Hunter
Journal:  Tuberculosis (Edinb)       Date:  2016-01-02       Impact factor: 3.131

5.  Evaluating the Toxicity Reduction With Computed Tomographic Ventilation Functional Avoidance Radiation Therapy.

Authors:  Austin M Faught; Yuya Miyasaka; Noriyuki Kadoya; Richard Castillo; Edward Castillo; Yevgeniy Vinogradskiy; Tokihiro Yamamoto
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-04-26       Impact factor: 7.038

6.  Evaluating Which Dose-Function Metrics Are Most Critical for Functional-Guided Radiation Therapy.

Authors:  Austin M Faught; Tokihiro Yamamoto; Richard Castillo; Edward Castillo; Jingjing Zhang; Moyed Miften; Yevgeniy Vinogradskiy
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-04-08       Impact factor: 7.038

7.  Reproducibility of four-dimensional computed tomography-based lung ventilation imaging.

Authors:  Tokihiro Yamamoto; Sven Kabus; Jens von Berg; Cristian Lorenz; Melody P Chung; Julian C Hong; Billy W Loo; Paul J Keall
Journal:  Acad Radiol       Date:  2012-09-10       Impact factor: 3.173

8.  Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements.

Authors:  Kaifang Du; Joseph M Reinhardt; Gary E Christensen; Kai Ding; John E Bayouth
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

9.  Reproducibility of intensity-based estimates of lung ventilation.

Authors:  Kaifang Du; John E Bayouth; Kai Ding; Gary E Christensen; Kunlin Cao; Joseph M Reinhardt
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

10.  Use of 4-dimensional computed tomography-based ventilation imaging to correlate lung dose and function with clinical outcomes.

Authors:  Yevgeniy Vinogradskiy; Richard Castillo; Edward Castillo; Susan L Tucker; Zhongxing Liao; Thomas Guerrero; Mary K Martel
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-03-06       Impact factor: 7.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.