Literature DB >> 28516043

Quantification of regional deformation of the lungs by non-rigid registration of three-dimensional contrast-enhanced magnetic resonance imaging.

Jiaxin Shao1, Peng Hu1,2.   

Abstract

BACKGROUND: Assessment of lung function is vital for the diagnosis of a variety of pathological conditions. Research has been proposed to study pulmonary mechanics and kinematics using two-dimensional (2D) magnetic resonance imaging (MRI). This allows estimation of regional lung tissue mechanics but is limited to 2D information. An approach based on three-dimensional (3D) contrast-enhanced MR angiogram of pulmonary blood vessels and a non-rigid image registration technique is proposed for quantification of lung regional deformations, which can potentially be used for assessment of pulmonary parenchymal mechanics and regional ventilation for disease diagnosis without ionizing radiation.
METHODS: On three volunteers, an end-expiration scan and end-inspiration scan was acquired successively for each volunteer using a 3D breath-hold contrast-enhanced MRI sequence several minutes after gadolinium injection. Subsequently, a rectangle box lung mask is manually selected for each end-expiration scan, applying non-rigid registration algorithms using cubic B-splines as transformations to align each pair of images. This incorporates the Normalized Correlation Coefficient similarity with the bending energy term as cost function with a multi-resolution multi-grid approach. Finally, the lung regional 3D deformations were obtained using the transformations obtained by registration. The alignment accuracy after non-rigid registration was estimated by using a set of branch points of pulmonary blood vessels as anatomical landmarks for each pair of images.
RESULTS: With contrast enhancement, the pulmonary blood vessel signal was enhanced, which greatly facilitated the non-rigid registration in the lung parenchyma. The average landmarks distances in three pairs of datasets are reduced from 17.9, 20.3 and 16.3 mm, to 1.0, 1.6 and 1.2 mm, respectively, by non-rigid registration. After registration, the average distances error of each pair of datasets was less than 0.6 mm in the right-to-left (RL) direction, less than 0.9 mm in the inferior-to-superior (IS) direction, and less than 1.2 mm in the anterior-to-posterior (AP) direction.
CONCLUSIONS: Results demonstrated that the proposed method can accurately register lungs with large deformations to evaluate lung regional deformation. It may be used for quantitative assessment of 3D lung regional ventilation avoiding ionizing radiation.

Entities:  

Keywords:  Lung; magnetic resonance imaging (MRI); non-rigid registration; regional function

Year:  2017        PMID: 28516043      PMCID: PMC5418144          DOI: 10.21037/qims.2017.01.01

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  26 in total

Review 1.  Visualizing lung function with positron emission tomography.

Authors:  R Scott Harris; Daniel P Schuster
Journal:  J Appl Physiol (1985)       Date:  2006-10-12

2.  Vertical gradients in regional lung density and perfusion in the supine human lung: the Slinky effect.

Authors:  Susan R Hopkins; A Cortney Henderson; David L Levin; Kei Yamada; Tatsuya Arai; Richard B Buxton; G Kim Prisk
Journal:  J Appl Physiol (1985)       Date:  2007-03-29

3.  4D-CT motion estimation using deformable image registration and 5D respiratory motion modeling.

Authors:  Deshan Yang; Wei Lu; Daniel A Low; Joseph O Deasy; Andrew J Hope; Issam El Naqa
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

4.  elastix: a toolbox for intensity-based medical image registration.

Authors:  Stefan Klein; Marius Staring; Keelin Murphy; Max A Viergever; Josien P W Pluim
Journal:  IEEE Trans Med Imaging       Date:  2009-11-17       Impact factor: 10.048

5.  Evaluation of registration methods on thoracic CT: the EMPIRE10 challenge.

Authors:  Keelin Murphy; Bram van Ginneken; Joseph M Reinhardt; Sven Kabus; Kai Ding; Xiang Deng; Kunlin Cao; Kaifang Du; Gary E Christensen; Vincent Garcia; Tom Vercauteren; Nicholas Ayache; Olivier Commowick; Grégoire Malandain; Ben Glocker; Nikos Paragios; Nassir Navab; Vladlena Gorbunova; Jon Sporring; Marleen de Bruijne; Xiao Han; Mattias P Heinrich; Julia A Schnabel; Mark Jenkinson; Cristian Lorenz; Marc Modat; Jamie R McClelland; Sébastien Ourselin; Sascha E A Muenzing; Max A Viergever; Dante De Nigris; D Louis Collins; Tal Arbel; Marta Peroni; Rui Li; Gregory C Sharp; Alexander Schmidt-Richberg; Jan Ehrhardt; René Werner; Dirk Smeets; Dirk Loeckx; Gang Song; Nicholas Tustison; Brian Avants; James C Gee; Marius Staring; Stefan Klein; Berend C Stoel; Martin Urschler; Manuel Werlberger; Jef Vandemeulebroucke; Simon Rit; David Sarrut; Josien P W Pluim
Journal:  IEEE Trans Med Imaging       Date:  2011-05-31       Impact factor: 10.048

6.  Comparison between multivolume CT-based surrogates of regional ventilation in healthy subjects.

Authors:  Francesca Pennati; Caterina Salito; Guido Baroni; Jason Woods; Andrea Aliverti
Journal:  Acad Radiol       Date:  2014-08-07       Impact factor: 3.173

Review 7.  MRI of the lung: state of the art.

Authors:  Mark Wielpütz; Hans-Ulrich Kauczor
Journal:  Diagn Interv Radiol       Date:  2012-03-20       Impact factor: 2.630

8.  Reproducibility of intensity-based estimates of lung ventilation.

Authors:  Kaifang Du; John E Bayouth; Kai Ding; Gary E Christensen; Kunlin Cao; Joseph M Reinhardt
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

9.  Non-contrast-enhanced perfusion and ventilation assessment of the human lung by means of fourier decomposition in proton MRI.

Authors:  Grzegorz Bauman; Michael Puderbach; Michael Deimling; Vladimir Jellus; Christophe Chefd'hotel; Julien Dinkel; Christian Hintze; Hans-Ulrich Kauczor; Lothar R Schad
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

Review 10.  Functional lung imaging using hyperpolarized gas MRI.

Authors:  Sean B Fain; Frank R Korosec; James H Holmes; Rafael O'Halloran; Ronald L Sorkness; Thomas M Grist
Journal:  J Magn Reson Imaging       Date:  2007-05       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.