The VAMPIRE challenge: A multi-institutional validation study of CT ventilation imaging.

John Kipritidis1,2, Bilal A Tahir3,4, Guillaume Cazoulat5, Michael S Hofman6, Shankar Siva6, Jason Callahan6, Nicholas Hardcastle6, Tokihiro Yamamoto7, Gary E Christensen8, Joseph M Reinhardt8, Noriyuki Kadoya9, Taylor J Patton10, Sarah E Gerard8, Isabella Duarte11, Ben Archibald-Heeren12,13, Mikel Byrne12, Rick Sims14, Scott Ramsay14, Jeremy T Booth1,15, Enid Eslick1,2, Fiona Hegi-Johnson2,6, Henry C Woodruff16, Rob H Ireland3, Jim M Wild4, Jing Cai11,17, John E Bayouth10, Kristy Brock5, Paul J Keall2.   

Abstract

PURPOSE: CT ventilation imaging (CTVI) is being used to achieve functional avoidance lung cancer radiation therapy in three clinical trials (NCT02528942, NCT02308709, NCT02843568). To address the need for common CTVI validation tools, we have built the Ventilation And Medical Pulmonary Image Registration Evaluation (VAMPIRE) Dataset, and present the results of the first VAMPIRE Challenge to compare relative ventilation distributions between different CTVI algorithms and other established ventilation imaging modalities.
METHODS: The VAMPIRE Dataset includes 50 pairs of 4DCT scans and corresponding clinical or experimental ventilation scans, referred to as reference ventilation images (RefVIs). The dataset includes 25 humans imaged with Galligas 4DPET/CT, 21 humans imaged with DTPA-SPECT, and 4 sheep imaged with Xenon-CT. For the VAMPIRE Challenge, 16 subjects were allocated to a training group (with RefVI provided) and 34 subjects were allocated to a validation group (with RefVI blinded). Seven research groups downloaded the Challenge dataset and uploaded CTVIs based on deformable image registration (DIR) between the 4DCT inhale/exhale phases. Participants used DIR methods broadly classified into B-splines, Free-form, Diffeomorphisms, or Biomechanical modeling, with CT ventilation metrics based on the DIR evaluation of volume change, Hounsfield Unit change, or various hybrid approaches. All CTVIs were evaluated against the corresponding RefVI using the voxel-wise Spearman coefficient r S , and Dice similarity coefficients evaluated for low function lung ( DSC low ) and high function lung ( DSC high ).
RESULTS: A total of 37 unique combinations of DIR method and CT ventilation metric were either submitted by participants directly or derived from participant-submitted DIR motion fields using the in-house software, VESPIR. The r S and DSC results reveal a high degree of inter-algorithm and intersubject variability among the validation subjects, with algorithm rankings changing by up to ten positions depending on the choice of evaluation metric. The algorithm with the highest overall cross-modality correlations used a biomechanical model-based DIR with a hybrid ventilation metric, achieving a median (range) of 0.49 (0.27-0.73) for r S , 0.52 (0.36-0.67) for DSC low , and 0.45 (0.28-0.62) for DSC high . All other algorithms exhibited at least one negative r S value, and/or one DSC value less than 0.5.
CONCLUSIONS: The VAMPIRE Challenge results demonstrate that the cross-modality correlation between CTVIs and the RefVIs varies not only with the choice of CTVI algorithm but also with the choice of RefVI modality, imaging subject, and the evaluation metric used to compare relative ventilation distributions. This variability may arise from the fact that each of the different CTVI algorithms and RefVI modalities provides a distinct physiologic measurement. Ultimately this variability, coupled with the lack of a "gold standard," highlights the ongoing importance of further validation studies before CTVI can be widely translated from academic centers to the clinic. It is hoped that the information gleaned from the VAMPIRE Challenge can help inform future validation efforts.
© 2018 American Association of Physicists in Medicine.

Entities:  

Keywords:  4DCT; CT ventilation imaging; deformable image registration; lung cancer

Mesh:

Year:  2019        PMID: 30575051      PMCID: PMC6605778          DOI: 10.1002/mp.13346

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  36 in total

1.  Accuracy of finite element model-based multi-organ deformable image registration.

Authors:  K K Brock; M B Sharpe; L A Dawson; S M Kim; D A Jaffray
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

2.  Dynamic ventilation imaging from four-dimensional computed tomography.

Authors:  Thomas Guerrero; Kevin Sanders; Edward Castillo; Yin Zhang; Luc Bidaut; Tinsu Pan; Ritsuko Komaki
Journal:  Phys Med Biol       Date:  2006-01-25       Impact factor: 3.609

3.  Comparison of image registration based measures of regional lung ventilation from dynamic spiral CT with Xe-CT.

Authors:  Kai Ding; Kunlin Cao; Matthew K Fuld; Kaifang Du; Gary E Christensen; Eric A Hoffman; Joseph M Reinhardt
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

4.  Registration-based estimates of local lung tissue expansion compared to xenon CT measures of specific ventilation.

Authors:  Joseph M Reinhardt; Kai Ding; Kunlin Cao; Gary E Christensen; Eric A Hoffman; Shalmali V Bodas
Journal:  Med Image Anal       Date:  2008-04-12       Impact factor: 8.545

5.  Results of a multi-institution deformable registration accuracy study (MIDRAS).

Authors:  Kristy K Brock
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-11-10       Impact factor: 7.038

6.  Evaluation of registration methods on thoracic CT: the EMPIRE10 challenge.

Authors:  Keelin Murphy; Bram van Ginneken; Joseph M Reinhardt; Sven Kabus; Kai Ding; Xiang Deng; Kunlin Cao; Kaifang Du; Gary E Christensen; Vincent Garcia; Tom Vercauteren; Nicholas Ayache; Olivier Commowick; Grégoire Malandain; Ben Glocker; Nikos Paragios; Nassir Navab; Vladlena Gorbunova; Jon Sporring; Marleen de Bruijne; Xiao Han; Mattias P Heinrich; Julia A Schnabel; Mark Jenkinson; Cristian Lorenz; Marc Modat; Jamie R McClelland; Sébastien Ourselin; Sascha E A Muenzing; Max A Viergever; Dante De Nigris; D Louis Collins; Tal Arbel; Marta Peroni; Rui Li; Gregory C Sharp; Alexander Schmidt-Richberg; Jan Ehrhardt; René Werner; Dirk Smeets; Dirk Loeckx; Gang Song; Nicholas Tustison; Brian Avants; James C Gee; Marius Staring; Stefan Klein; Berend C Stoel; Martin Urschler; Manuel Werlberger; Jef Vandemeulebroucke; Simon Rit; David Sarrut; Josien P W Pluim
Journal:  IEEE Trans Med Imaging       Date:  2011-05-31       Impact factor: 10.048

7.  Hyperpolarized (3)He magnetic resonance imaging: comparison with four-dimensional x-ray computed tomography imaging in lung cancer.

Authors:  Lindsay Mathew; Andrew Wheatley; Richard Castillo; Edward Castillo; George Rodrigues; Thomas Guerrero; Grace Parraga
Journal:  Acad Radiol       Date:  2012-09-19       Impact factor: 3.173

8.  68Ga PET/CT ventilation-perfusion imaging for pulmonary embolism: a pilot study with comparison to conventional scintigraphy.

Authors:  Michael S Hofman; Jean-Mathieu Beauregard; Thomas W Barber; Oliver C Neels; Peter Eu; Rodney J Hicks
Journal:  J Nucl Med       Date:  2011-09-09       Impact factor: 10.057

Review 9.  What can computed tomography and magnetic resonance imaging tell us about ventilation?

Authors:  Brett A Simon; David W Kaczka; Alexander A Bankier; Grace Parraga
Journal:  J Appl Physiol (1985)       Date:  2012-05-31

10.  Four-dimensional computed tomography pulmonary ventilation images vary with deformable image registration algorithms and metrics.

Authors:  Tokihiro Yamamoto; Sven Kabus; Tobias Klinder; Jens von Berg; Cristian Lorenz; Billy W Loo; Paul J Keall
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

View more
  15 in total

1.  Results of a Multi-Institutional Phase 2 Clinical Trial for 4DCT-Ventilation Functional Avoidance Thoracic Radiation Therapy.

Authors:  Yevgeniy Vinogradskiy; Richard Castillo; Edward Castillo; Leah Schubert; Bernard L Jones; Austin Faught; Laurie E Gaspar; Jennifer Kwak; Daniel W Bowles; Timothy Waxweiler; Jingjing M Dougherty; Dexiang Gao; Craig Stevens; Moyed Miften; Brian Kavanagh; Inga Grills; Chad G Rusthoven; Thomas Guerrero
Journal:  Int J Radiat Oncol Biol Phys       Date:  2021-11-09       Impact factor: 7.038

2.  Ventilation measurements using fast-helical free-breathing computed tomography.

Authors:  Daniel A Low; Dylan O'Connell; Michael Lauria; Bradley Stiehl; Louise Naumann; Percy Lee; John Hegde; Igor Barjaktarevic; Jonathan Goldin; Anand Santhanam
Journal:  Med Phys       Date:  2021-09-04       Impact factor: 4.506

3.  A Transfer Learning Framework for Deep Learning-Based CT-to-Perfusion Mapping on Lung Cancer Patients.

Authors:  Ge Ren; Bing Li; Sai-Kit Lam; Haonan Xiao; Yu-Hua Huang; Andy Lai-Yin Cheung; Yufei Lu; Ronghu Mao; Hong Ge; Feng-Ming Spring Kong; Wai-Yin Ho; Jing Cai
Journal:  Front Oncol       Date:  2022-07-01       Impact factor: 5.738

4.  Four-dimensional computed tomography-based biomechanical measurements of pulmonary function and their correlation with clinical outcome for lung stereotactic body radiation therapy patients.

Authors:  Hoda Sharifi; Gary C McDonald; Joon Kyu Lee; Munther I Ajlouni; Indrin J Chetty; Hualiang Zhong
Journal:  Quant Imaging Med Surg       Date:  2019-07

5.  Characterizing spatial differences between SPECT-ventilation and SPECT-perfusion in patients with lung cancer undergoing radiotherapy.

Authors:  Farnoush Forghani; Taylor Patton; Jennifer Kwak; David Thomas; Quentin Diot; Chad Rusthoven; Richard Castillo; Edward Castillo; Inga Grills; Thomas Guerrero; Moyed Miften; Yevgeniy Vinogradskiy
Journal:  Radiother Oncol       Date:  2021-05-06       Impact factor: 6.901

6.  Combining Serial and Parallel Functionality in Functional Lung Avoidance Radiation Therapy.

Authors:  Esther M Vicente; Arezoo Modiri; John Kipritidis; Kun-Chang Yu; Kai Sun; Jochen Cammin; Arun Gopal; Jingzhu Xu; Sina Mossahebi; Aaron Hagan; Yulong Yan; Daniel Rockwell Owen; Pranshu Mohindra; Martha M Matuszak; Robert D Timmerman; Amit Sawant
Journal:  Int J Radiat Oncol Biol Phys       Date:  2022-03-09       Impact factor: 8.013

7.  Variations Between Dose-Ventilation and Dose-Perfusion Metrics in Radiation Therapy Planning for Lung Cancer.

Authors:  Yujiro Nakajima; Noriyuki Kadoya; Tomoki Kimura; Kazunari Hioki; Keiichi Jingu; Tokihiro Yamamoto
Journal:  Adv Radiat Oncol       Date:  2020-03-20

8.  Hyperpolarized 129Xe Magnetic Resonance Imaging for Functional Avoidance Treatment Planning in Thoracic Radiation Therapy: A Comparison of Ventilation- and Gas Exchange-Guided Treatment Plans.

Authors:  Leith J Rankine; Ziyi Wang; Chris R Kelsey; Elianna Bier; Bastiaan Driehuys; Lawrence B Marks; Shiva K Das
Journal:  Int J Radiat Oncol Biol Phys       Date:  2021-07-13       Impact factor: 7.038

9.  Geodesic density regression for correcting 4DCT pulmonary respiratory motion artifacts.

Authors:  Wei Shao; Yue Pan; Oguz C Durumeric; Joseph M Reinhardt; John E Bayouth; Mirabela Rusu; Gary E Christensen
Journal:  Med Image Anal       Date:  2021-06-21       Impact factor: 13.828

10.  A generative adversarial network (GAN)-based technique for synthesizing realistic respiratory motion in the extended cardiac-torso (XCAT) phantoms.

Authors:  Yushi Chang; Zhuoran Jiang; William Paul Segars; Zeyu Zhang; Kyle Lafata; Jing Cai; Fang-Fang Yin; Lei Ren
Journal:  Phys Med Biol       Date:  2021-05-31       Impact factor: 4.174

View more