Optimization of energy window for 90Y bremsstrahlung SPECT imaging for detection tasks using the ideal observer with model-mismatch.

Xing Rong1, Michael Ghaly, Eric C Frey.   

Abstract

PURPOSE: In yttrium-90 ((90)Y) microsphere brachytherapy (radioembolization) of unresectable liver cancer, posttherapy (90)Y bremsstrahlung single photon emission computed tomography (SPECT) has been used to document the distribution of microspheres in the patient and to help predict potential side effects. The energy window used during projection acquisition can have a significant effect on image quality. Thus, using an optimal energy window is desirable. However, there has been great variability in the choice of energy window due to the continuous and broad energy distribution of (90)Y bremsstrahlung photons. The area under the receiver operating characteristic curve (AUC) for the ideal observer (IO) is a widely used figure of merit (FOM) for optimizing the imaging system for detection tasks. The IO implicitly assumes a perfect model of the image formation process. However, for (90)Y bremsstrahlung SPECT there can be substantial model-mismatch (i.e., difference between the actual image formation process and the model of it assumed in reconstruction), and the amount of the model-mismatch depends on the energy window. It is thus important to account for the degradation of the observer performance due to model-mismatch in the optimization of the energy window. The purpose of this paper is to optimize the energy window for (90)Y bremsstrahlung SPECT for a detection task while taking into account the effects of the model-mismatch.
METHODS: An observer, termed the ideal observer with model-mismatch (IO-MM), has been proposed previously to account for the effects of the model-mismatch on IO performance. In this work, the AUC for the IO-MM was used as the FOM for the optimization. To provide a clinically realistic object model and imaging simulation, the authors used a background-known-statistically and signal-known-statistically task. The background was modeled as multiple compartments in the liver with activity parameters independently following a Gaussian distribution; the signal was modeled as a tumor with a Gaussian-distributed activity parameter located randomly with equal probability at one of three positions. The IO test statistics (i.e., likelihood ratios) were estimated using Markov-chain Monte Carlo methods. The authors realistically modeled human anatomy using a digital phantom code, and realistically simulated (90)Y bremsstrahlung SPECT imaging with a clinical SPECT system and typical imaging parameters using a previously validated Monte Carlo bremsstrahlung simulation method. Model-mismatch was included by modeling image formation process in the calculation of IO test statistics using an analytic modeling method previously developed for quantitative (90)Y bremsstrahlung SPECT. To demonstrate the effects of the model-mismatch on the detection task, the authors optimized the energy window both with and without model-mismatch included in the IO.
RESULTS: For all the energy windows, the AUC values for the IO-MM were smaller than that for the IO. The optimal windows for the IO-MM and the IO were 80-180 and 60-400 keV, respectively.
CONCLUSIONS: The authors have demonstrated the degradation of the ideal performance due to model-mismatch and optimized the energy window for (90)Y bremsstrahlung SPECT for detection tasks by accounting for the effects of the model-mismatch. The obtained optimal window was much narrower when taking into account the model-mismatch and similar to that obtained previously for estimation tasks.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23718607      PMCID: PMC3669146          DOI: 10.1118/1.4805095

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  20 in total

1.  Basic principles of ROC analysis.

Authors:  C E Metz
Journal:  Semin Nucl Med       Date:  1978-10       Impact factor: 4.446

2.  Application of task-based measures of image quality to optimization and evaluation of three-dimensional reconstruction-based compensation methods in myocardial perfusion SPECT.

Authors:  Eric C Frey; Karen L Gilland; Benjamin M W Tsui
Journal:  IEEE Trans Med Imaging       Date:  2002-09       Impact factor: 10.048

3.  Ideal-observer performance under signal and background uncertainty.

Authors:  S Park; M A Kupinski; E Clarkson; H H Barrett
Journal:  Inf Process Med Imaging       Date:  2003-07

4.  A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imaging.

Authors:  Xing Rong; Yong Du; Eric C Frey
Journal:  Phys Med Biol       Date:  2012-05-23       Impact factor: 3.609

5.  Development and evaluation of an improved quantitative (90)Y bremsstrahlung SPECT method.

Authors:  Xing Rong; Yong Du; Michael Ljungberg; Erwann Rault; Stefaan Vandenberghe; Eric C Frey
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

6.  Recommendations of the American Association of Physicists in Medicine on dosimetry, imaging, and quality assurance procedures for 90Y microsphere brachytherapy in the treatment of hepatic malignancies.

Authors:  William A Dezarn; Jeffery T Cessna; Larry A DeWerd; Wenzheng Feng; Vanessa L Gates; James Halama; Andrew S Kennedy; Subir Nag; Mehrdad Sarfaraz; Varun Sehgal; Reed Selwyn; Michael G Stabin; Bruce R Thomadsen; Lawrence E Williams; Riad Salem
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

7.  A Monte Carlo program for the simulation of scintillation camera characteristics.

Authors:  M Ljungberg; S E Strand
Journal:  Comput Methods Programs Biomed       Date:  1989-08       Impact factor: 5.428

8.  An intuitive approach to receiver operating characteristic curve analysis.

Authors:  D A Turner
Journal:  J Nucl Med       Date:  1978-02       Impact factor: 10.057

9.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

10.  Channelized hotelling and human observer correlation for lesion detection in hepatic SPECT imaging.

Authors:  H C Gifford; M A King; D J de Vries; E J Soares
Journal:  J Nucl Med       Date:  2000-03       Impact factor: 10.057

View more
  10 in total

1.  A collimator optimization method for quantitative imaging: application to Y-90 bremsstrahlung SPECT.

Authors:  Xing Rong; Eric C Frey
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

Review 2.  Quantitative Imaging of Alpha-Emitting Therapeutic Radiopharmaceuticals.

Authors:  Youngho Seo
Journal:  Nucl Med Mol Imaging       Date:  2019-02-18

3.  Practical reconstruction protocol for quantitative (90)Y bremsstrahlung SPECT/CT.

Authors:  W Siman; J K Mikell; S C Kappadath
Journal:  Med Phys       Date:  2016-09       Impact factor: 4.071

4.  Collimator optimization and collimator-detector response compensation in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.

Authors:  Michael Ghaly; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-02-19       Impact factor: 3.609

5.  Optimization of energy window and evaluation of scatter compensation methods in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.

Authors:  Michael Ghaly; Jonathan M Links; Eric Frey
Journal:  J Med Imaging (Bellingham)       Date:  2015-01

6.  Effect of ME Collimator Characteristic, Energy Window Width, and Reconstruction Algorithm Selection on Imaging Performance of Yttrium-90: Simulation Study.

Authors:  Payvand Taherparvar; Nazila Shahmari
Journal:  Nucl Med Mol Imaging       Date:  2019-11-13

Review 7.  Advances in SPECT for Optimizing the Liver Tumors Radioembolization Using Yttrium-90 Microspheres.

Authors:  Hoda Rezaei Roshan; Ahmadreza Azarm; Babak Mahmoudian; Jalil Pirayesh Islamian
Journal:  World J Nucl Med       Date:  2015 May-Aug

Review 8.  Theranostic Imaging of Yttrium-90.

Authors:  Chadwick L Wright; Jun Zhang; Michael F Tweedle; Michael V Knopp; Nathan C Hall
Journal:  Biomed Res Int       Date:  2015-05-28       Impact factor: 3.411

9.  PET/CT-Based Dosimetry in 90Y-Microsphere Selective Internal Radiation Therapy: Single Cohort Comparison With Pretreatment Planning on (99m)Tc-MAA Imaging and Correlation With Treatment Efficacy.

Authors:  Yoo Sung Song; Jin Chul Paeng; Hyo-Cheol Kim; Jin Wook Chung; Gi Jeong Cheon; June-Key Chung; Dong Soo Lee; Keon Wook Kang
Journal:  Medicine (Baltimore)       Date:  2015-06       Impact factor: 1.889

10.  Energy Window and Contrast Optimization for Single-photon Emission Computed Tomography Bremsstrahlung Imaging with Yttrium-90.

Authors:  Youssef Bouzekraoui; Farida Bentayeb; Hicham Asmi; Faustino Bonutti
Journal:  Indian J Nucl Med       Date:  2019 Apr-Jun
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.