OBJECTIVE: To test the hypothesis that wide area detector face transplant surgical planning CT angiograms with simulated lower radiation dose and iterative reconstruction (AIDR3D) are comparable in image quality to those with standard tube current and filtered back projection (FBP) reconstruction.Entities:
Mesh:
Year: 2013 PMID: 23638180 PMCID: PMC3637203 DOI: 10.1371/journal.pone.0063079
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Figure 1Boxplots of signal-to-noise ratio (SNR) for each reconstruction.
A- Muscle. B- Fat. C- Artery. D- Vein.
Figure 2Boxplots of contrast-to-noise ratio (CNR) of each reconstruction.
A- Artery. B- Vein.
Mean image quality score (average of two readers) for each of the eight image reconstruction strategies at each vessel.
| FBP | AIDR3D | ||||||||||
| mAs | mAs | p-value | |||||||||
| No. | 100% | 75% | 62% | 50% | 100% | 75% | 62% | 50% | |||
| Large arteries | Internal carotid | 4 | 4.00 | 3.75 | 4.00 | 3.63 | 3.88 | 3.88 | 4.00 | 4.00 | - |
| External carotid | 4 | 4.00 | 3.75 | 3.88 | 3.63 | 3.88 | 4.00 | 4.00 | 4.00 | - | |
| Overall | 8 | 4.00 | 3.75 | 3.94 | 3.63 | 3.88 | 3.94 | 4.00 | 4.00 | 0.798 | |
| Small arteries | Facial | 2 | 4.00 | 3.75 | 3.75 | 3.75 | 4.00 | 4.00 | 4.00 | 4.00 | - |
| Lingual | 4 | 3.88 | 3.63 | 3.75 | 3.50 | 3.75 | 3.75 | 3.88 | 3.75 | - | |
| Superior thyroid | 4 | 3.50 | 3.25 | 3.38 | 3.13 | 3.50 | 3.50 | 3.63 | 3.50 | - | |
| Superficial temporal | 4 | 3.50 | 3.50 | 3.25 | 3.25 | 3.75 | 3.63 | 3.50 | 3.63 | - | |
| Overall | 14 | 3.68 | 3.50 | 3.50 | 3.36 | 3.71 | 3.68 | 3.71 | 3.68 | <0.001 | |
| Artery overall | 22 | 3.77 | 3.61 | 3.64 | 3.45 | 3.80 | 3.77 | 3.82 | 3.80 | <0.001 | |
| Veins | Internal jugular | 4 | 4.00 | 3.88 | 3.88 | 3.88 | 3.88 | 3.88 | 4.00 | 4.00 | - |
| External jugular | 3 | 3.67 | 3.67 | 3.67 | 3.50 | 3.67 | 3.67 | 3.67 | 3.67 | - | |
| Common facial | 4 | 3.63 | 3.38 | 3.50 | 3.38 | 3.50 | 3.50 | 3.63 | 3.63 | - | |
| Vein overall | 11 | 3.77 | 3.64 | 3.68 | 3.59 | 3.73 | 3.68 | 3.77 | 3.77 | <0.001 | |
Significantly lower compared to at least one other reconstruction. “-” indicates no statistical comparison due to a small number in each subgroup.
Figure 3Representative images with FBP and AIDR3D reconstructions.
Image noise increases on images reconstructed using FBP with original tube current (A, D) and simulated 50% dose reduction (B, E), especially around the metal in the mandible (A, B), while images reconstructed using AIDR3D with simulated 50% dose reduction (C, F) achieve reduced artifacts and noise. The right lingual artery (D–F) is poorly delineated in the image with FBP and simulated 50% dose reduction (E).
Figure 4Representative images with FBP and AIDR3D reconstructions.
The branch of the left facial artery (arrow) is clearly depicted on the image reconstructed using AIDR3D with simulated 50% dose reduction (C), while it is obscured on the image reconstructed using FBP with original dose (A) and is hard to detect on the image using FBP with simulated 50% dose reduction (B) due to streak artifacts.