Literature DB >> 18029873

Reduced-dose CT: effect on reader evaluation in detection of pulmonary embolism.

John D MacKenzie1, Javier Nazario-Larrieu, Tianxi Cai, M Stephen Ledbetter, Maria Alejandra Duran-Mendicuti, Philip F Judy, Frank J Rybicki.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate the effect of reduction in radiation dose on CT detection of pulmonary embolism. SUBJECTS AND METHODS: Emergency department patients were evaluated for pulmonary embolism with standard and simulated reduced-dose CT angiography. Simulated lower-dose CT angiograms obtained at 90, 45, 22, and 10 mAs(eff) were reconstructed by mathematical addition of noise to the standard dose (180 mAs(eff)) data from the images of 18 patients with and 20 patients without pulmonary embolism. Four radiologists blinded to the study parameters separately interpreted each CT angiogram. Dose trends for subjective measures (diagnostic certainty, image quality, and perceived technical limitations) were evaluated, test characteristics for the detection of pulmonary embolism were computed, and clot burden was measured.
RESULTS: Readers indicated significant reductions in diagnostic certainty (p < 0.02) and image quality (p < 0.02) and an increase in perceived technical limitations (p < 0.01) as the simulated radiation dose was decreased. These subjective measures also showed significant adverse dose trends when the mAs(eff) was reduced (p < 0.001). At reduced radiation doses, the sensitivity and positive predictive value for detection of pulmonary embolism diminished significantly. The sensitivity was 0.94 (lower bound of 0.95 CI, 0.92); specificity, 0.99 (lower bound of 0.95 CI, 0.98); positive predictive value, 0.95 (lower bound of 0.95 CI, 0.92); and negative predictive value, 0.99 (lower bound of 0.95 CI, 0.97). All patients had a low to moderate clot burden.
CONCLUSION: Reduction in dose for CT angiography in the detection of pulmonary embolism has a significant adverse effect on readers' subjective assessment of diagnostic confidence and image quality. Detection of pulmonary embolism also decreases as the tube current dose is reduced.

Entities:  

Mesh:

Year:  2007        PMID: 18029873     DOI: 10.2214/AJR.07.2686

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  12 in total

1.  Validation of CT dose-reduction simulation.

Authors:  Parinaz Massoumzadeh; Steven Don; Charles F Hildebolt; Kyongtae T Bae; Bruce R Whiting
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

2.  Dose and image quality at CT pulmonary angiography-comparison of first and second generation dual-energy CT and 64-slice CT.

Authors:  Ralf W Bauer; Sebastian Kramer; Matthias Renker; Boris Schell; Maya Christina Larson; Martin Beeres; Thomas Lehnert; Volkmar Jacobi; Thomas J Vogl; Josef Matthias Kerl
Journal:  Eur Radiol       Date:  2011-05-27       Impact factor: 5.315

3.  Improved diagnostic confidence and accuracy of pediatric elbow fractures with digital tomosynthesis.

Authors:  Matthew A Zapala; Kristin Livingston; Danial Bokhari; Andrew S Phelps; Jesse L Courtier; Collin Ma; Youngho Seo; John D MacKenzie
Journal:  Pediatr Radiol       Date:  2019-11-19

4.  Reduced z-axis coverage in multidetector-row CT pulmonary angiography decreases radiation dose and diagnostic accuracy of alternative diseases.

Authors:  N Michalakis; C Keyzer; V De Maertelaer; D Tack; P A Gevenois
Journal:  Br J Radiol       Date:  2013-11-20       Impact factor: 3.039

5.  Image quality of low mA CT pulmonary angiography reconstructed with model based iterative reconstruction versus standard CT pulmonary angiography reconstructed with filtered back projection: an equivalency trial.

Authors:  Xavier Montet; Anne-Lise Hachulla; Angeliki Neroladaki; Frederic Lador; Thierry Rochat; Diomidis Botsikas; Christoph D Becker
Journal:  Eur Radiol       Date:  2014-12-21       Impact factor: 5.315

6.  Influence of body habitus and use of oral contrast on reader confidence in patients with suspected acute appendicitis using 64 MDCT.

Authors:  Stephan W Anderson; James T Rhea; Holly N Milch; Al Ozonoff; Brian C Lucey; Jorge A Soto
Journal:  Emerg Radiol       Date:  2010-05-23

7.  Reduced Z-axis coverage multidetector CT angiography for suspected acute pulmonary embolism could decrease dose and maintain diagnostic accuracy.

Authors:  Joshua A Kallen; Bret F Coughlin; Michael T O'Loughlin; Barry Stein
Journal:  Emerg Radiol       Date:  2009-05-26

8.  Reduced radiation exposure for face transplant surgical planning computed tomography angiography.

Authors:  Kurt Schultz; Elizabeth George; Katherine M Mullen; Michael L Steigner; Dimitrios Mitsouras; Ericka M Bueno; Bohdan Pomahac; Frank J Rybicki; Kanako K Kumamaru
Journal:  PLoS One       Date:  2013-04-26       Impact factor: 3.240

9.  Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D).

Authors:  Marcus Y Chen; Michael L Steigner; Steve W Leung; Kanako K Kumamaru; Kurt Schultz; Richard T Mather; Andrew E Arai; Frank J Rybicki
Journal:  Int J Cardiovasc Imaging       Date:  2013-02-13       Impact factor: 2.357

10.  Ultra Low Dose CT Pulmonary Angiography with Iterative Reconstruction.

Authors:  Andreas Sauter; Thomas Koehler; Alexander A Fingerle; Bernhard Brendel; Vivien Richter; Michael Rasper; Ernst J Rummeny; Peter B Noël; Daniela Münzel
Journal:  PLoS One       Date:  2016-09-09       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.