Literature DB >> 22923280

Image quality of adaptive iterative dose reduction 3D of coronary CT angiography of 640-slice CT: comparison with filtered back-projection.

Roh-Eul Yoo1, Eun-Ah Park, Whal Lee, Hackjoon Shim, Yeo Koon Kim, Jin Wook Chung, Jae Hyung Park.   

Abstract

To assess the image quality of coronary CT angiography (CCTA) of 640-slice CT reconstructed by Adaptive Iterative Dose Reduction (AIDR) three-dimensional (3D) in comparison with the conventional filtered back-projection (FBP). CCTA images of 51 patients were scanned at the lowest tube voltage possible on condition that the built-in automatic exposure control system could suggest the optimal tube current. They were, then, reconstructed with FBP and AIDR 3D (standard). Objective measurements including CT density, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were performed. Subjective assessment was done by two radiologists, using a 5-point scale (0:nondiagnostic-4:excellent) based on the 15-coronary segment model which was grouped into three parts as the proximal, mid, and distal segmental classes. Radiation dose was also measured. AIDR images showed lower noise than FBP images (45.0 ± 9.4 vs. 73.4 ± 14.6 HU, p < 0.001) without any significant difference in CT density (665.5 ± 131.7 vs. 668 ± 136.3 HU, p = 0.8). Both SNR (15.0 ± 2.1 vs. 9.2 ± 1.7) and CNR (16.8 ± 2.3 vs. 10.4 ± 1.8) were significantly higher for AIDR than FBP (p < 0.001). Total subjective image quality score was also significantly improved in AIDR compared with FBP (3.1 ± 0.6 vs. 1.6 ± 0.4, p < 0.001), with better interpretability of the mid and distal segmental classes (100 vs. 95 % for the mid, p < 0.001; 100 vs. 90 % for the distal, p < 0.001). Mean effective radiation dose was 2.0 ± 1.0 mSv. The AIDR 3D reconstruction algorithm reduced image noise by 39 % compared with the FBP without affecting CT density, thus improving SNR and CNR for CCTA. Its advantages in interpretability were also confirmed by subjective evaluation by experts.

Entities:  

Mesh:

Year:  2012        PMID: 22923280     DOI: 10.1007/s10554-012-0113-6

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  27 in total

1.  Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients.

Authors:  Yoshiko Sagara; Amy K Hara; William Pavlicek; Alvin C Silva; Robert G Paden; Qing Wu
Journal:  AJR Am J Roentgenol       Date:  2010-09       Impact factor: 3.959

Review 2.  Computed tomography--old ideas and new technology.

Authors:  Dominik Fleischmann; F Edward Boas
Journal:  Eur Radiol       Date:  2011-01-20       Impact factor: 5.315

3.  Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience.

Authors:  Márcio Sommer Bittencourt; Bernhard Schmidt; Martin Seltmann; Gerd Muschiol; Dieter Ropers; Werner Günther Daniel; Stephan Achenbach
Journal:  Int J Cardiovasc Imaging       Date:  2010-12-01       Impact factor: 2.357

4.  Clinical evaluation of pulmonary nodules with single-exposure dual-energy subtraction chest radiography with an iterative noise-reduction algorithm.

Authors:  S Kido; J Ikezoe; H Naito; J Arisawa; S Tamura; T Kozuka; W Ito; K Shimura; H Kato
Journal:  Radiology       Date:  1995-02       Impact factor: 11.105

5.  Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: A pilot study.

Authors:  Kristina T Flicek; Amy K Hara; Alvin C Silva; Qing Wu; Mary B Peter; C Daniel Johnson
Journal:  AJR Am J Roentgenol       Date:  2010-07       Impact factor: 3.959

6.  A prospective evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction.

Authors:  Jonathon Leipsic; Giang Nguyen; Jaqueline Brown; Don Sin; John R Mayo
Journal:  AJR Am J Roentgenol       Date:  2010-11       Impact factor: 3.959

7.  Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Matthew D Gilman; Jiang Hsieh; Homer H Pien; Subba R Digumarthy; Jo-Anne O Shepard
Journal:  Radiology       Date:  2011-03-08       Impact factor: 11.105

8.  Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Jiang Hsieh; Paul E Licato; Synho Do; Homer H Pien; Michael A Blake
Journal:  Radiology       Date:  2010-09-09       Impact factor: 11.105

9.  Effects of nitroglycerin on the diagnostic accuracy of electrocardiogram-gated coronary computed tomography angiography.

Authors:  Eun Ju Chun; Whal Lee; Young Hoon Choi; Bon-Kwon Koo; Sang Il Choi; Hwan Jun Jae; Hyo-Cheol Kim; Young Ho So; Jin Wook Chung; Jae Hyung Park
Journal:  J Comput Assist Tomogr       Date:  2008 Jan-Feb       Impact factor: 1.826

Review 10.  CT radiation dose optimization and estimation: an update for radiologists.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2011-12-23       Impact factor: 3.500

View more
  29 in total

1.  The effect of iterative image reconstruction algorithms on the feasibility of automated plaque assessment in coronary CT angiography.

Authors:  Stefan B Puchner; Maros Ferencik; Mihaly Karolyi; Synho Do; Pal Maurovich-Horvat; Hans-Ulrich Kauczor; Udo Hoffmann; Christopher L Schlett
Journal:  Int J Cardiovasc Imaging       Date:  2013-08-30       Impact factor: 2.357

2.  Diagnosis of coronary artery disease in patients with atrial fibrillation using low tube voltage coronary CT angiography with isotonic low-concentration contrast agent.

Authors:  Yuning Pan; Qiuli Huang; Yingchao Zhu; Xinrong Zou; Huimin Chu; Xianfeng Du; Aijing Li; Shizhong Bu
Journal:  Int J Cardiovasc Imaging       Date:  2019-07-30       Impact factor: 2.357

3.  Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy.

Authors:  Rihyeon Kim; Eun-Ah Park; Whal Lee; Jin Wook Chung
Journal:  Eur Radiol       Date:  2016-02-23       Impact factor: 5.315

4.  Image quality and radiation reduction of 320-row area detector CT coronary angiography with optimal tube voltage selection and an automatic exposure control system: comparison with body mass index-adapted protocol.

Authors:  Jiyeon Lim; Eun-Ah Park; Whal Lee; Hackjoon Shim; Jin Wook Chung
Journal:  Int J Cardiovasc Imaging       Date:  2015-01-22       Impact factor: 2.357

Review 5.  Raise the bar and lower the dose: current and future strategies for radiation dose reduction in head and neck imaging.

Authors:  M Ibrahim; H Parmar; E Christodoulou; S Mukherji
Journal:  AJNR Am J Neuroradiol       Date:  2013-02-28       Impact factor: 3.825

6.  Accuracy of lung nodule volumetry in low-dose CT with iterative reconstruction: an anthropomorphic thoracic phantom study.

Authors:  K W Doo; E-Y Kang; H S Yong; O H Woo; K Y Lee; Y-W Oh
Journal:  Br J Radiol       Date:  2014-07-16       Impact factor: 3.039

Review 7.  Cardiovascular imaging 2013 in the International Journal of Cardiovascular Imaging.

Authors:  Hiram G Bezerra; Ricardo A Costa; Johan H C Reiber; Frank J Rybicki; Paul Schoenhagen; Arthur A Stillman; Johan De Sutter; Nico R L Van de Veire
Journal:  Int J Cardiovasc Imaging       Date:  2014-04       Impact factor: 2.357

8.  320-row coronary computed tomography angiography (CCTA) with automatic exposure control (AEC): effect of 100 kV versus 120 kV on image quality and dose exposure.

Authors:  Ernesto Di Cesare; Antonio Gennarelli; Alessandra Di Sibio; Valentina Felli; Marco Perri; Alessandra Splendiani; Giovanni Luca Gravina; Antonio Barile; Carlo Masciocchi
Journal:  Radiol Med       Date:  2016-05-12       Impact factor: 3.469

9.  Value of liver computed tomography with iodixanol 270, 80 kVp and iterative reconstruction.

Authors:  Diomidis Botsikas; Isabelle Barnaure; Sylvain Terraz; Christoph D Becker; Anastasia Kalovidouri; Xavier Montet
Journal:  World J Radiol       Date:  2016-07-28

10.  Assessment of dose exposure and image quality in coronary angiography performed by 640-slice CT: a comparison between adaptive iterative and filtered back-projection algorithm by propensity analysis.

Authors:  Ernesto Di Cesare; Antonio Gennarelli; Alessandra Di Sibio; Valentina Felli; Alessandra Splendiani; Giovanni Luca Gravina; Antonio Barile; Carlo Masciocchi
Journal:  Radiol Med       Date:  2014-02-20       Impact factor: 3.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.