Literature DB >> 21927791

CT image quality improvement using Adaptive Iterative Dose Reduction with wide-volume acquisition on 320-detector CT.

Alban Gervaise1, Benoît Osemont, Sophie Lecocq, Alain Noel, Emilien Micard, Jacques Felblinger, Alain Blum.   

Abstract

OBJECTIVES: To evaluate the impact of Adaptive Iterative Dose Reduction (AIDR) on image quality and radiation dose in phantom and patient studies.
METHODS: A phantom was examined in volumetric mode on a 320-detector CT at different tube currents from 25 to 550 mAs. CT images were reconstructed with AIDR and with Filtered Back Projection (FBP) reconstruction algorithm. Image noise, Contrast-to-Noise Ratio (CNR), Signal-to-Noise Ratio (SNR) and spatial resolution were compared between FBP and AIDR images. AIDR was then tested on 15 CT examinations of the lumbar spine in a prospective study. Again, FBP and AIDR images were compared. Image noise and SNR were analysed using a Wilcoxon signed-rank test.
RESULTS: In the phantom, spatial resolution assessment showed no significant difference between FBP and AIDR reconstructions. Image noise was lower with AIDR than with FBP images with a mean reduction of 40%. CNR and SNR were also improved with AIDR. In patients, quantitative and subjective evaluation showed that image noise was significantly lower with AIDR than with FBP. SNR was also greater with AIDR than with FBP.
CONCLUSION: Compared to traditional FBP reconstruction techniques, AIDR significantly improves image quality and has the potential to decrease radiation dose. KEY POINTS: This study showed that Adaptive Iterative Dose Reduction (AIDR) reduces image noise. In a phantom image noise was reduced without altering spatial resolution. In patients AIDR reduced the image noise in lumbar spine CT. AIDR can potentially reduce the dose for lumbar spine CT by 52%.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21927791     DOI: 10.1007/s00330-011-2271-7

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  25 in total

1.  Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Jeanne B Ackman; Subba R Digumarthy; Jiang Hsieh; Synho Do; Jo-Anne O Shepard; Matthew D Gilman
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

2.  Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation.

Authors:  Tom H Mulkens; Patrick Bellinck; Michel Baeyaert; Dirk Ghysen; Xavier Van Dijck; Elvier Mussen; Caroline Venstermans; Jean-Luc Termote
Journal:  Radiology       Date:  2005-08-26       Impact factor: 11.105

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

5.  CT iterative reconstruction in image space: a phantom study.

Authors:  C Ghetti; O Ortenzia; G Serreli
Journal:  Phys Med       Date:  2011-04-15       Impact factor: 2.685

Review 6.  Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm.

Authors:  Alvin C Silva; Holly J Lawder; Amy Hara; Jennifer Kujak; William Pavlicek
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

7.  The lumbar disc herniation. A computer-aided analysis of 2,504 operations.

Authors:  E V Spangfort
Journal:  Acta Orthop Scand Suppl       Date:  1972

8.  Exposure to low-dose ionizing radiation from medical imaging procedures.

Authors:  Reza Fazel; Harlan M Krumholz; Yongfei Wang; Joseph S Ross; Jersey Chen; Henry H Ting; Nilay D Shah; Khurram Nasir; Andrew J Einstein; Brahmajee K Nallamothu
Journal:  N Engl J Med       Date:  2009-08-27       Impact factor: 91.245

9.  Multidetector CT in patients suspected of having lumbar disk herniation: comparison of standard-dose and simulated low-dose techniques.

Authors:  Pascale Bohy; Viviane de Maertelaer; Aymeric Roquigny; Caroline Keyzer; Denis Tack; Pierre Alain Gevenois
Journal:  Radiology       Date:  2007-08       Impact factor: 11.105

10.  Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults.

Authors:  Aaron Sodickson; Pieter F Baeyens; Katherine P Andriole; Luciano M Prevedello; Richard D Nawfel; Richard Hanson; Ramin Khorasani
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

View more
  81 in total

1.  CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction.

Authors:  Ullrich Ebersberger; Francesco Tricarico; U Joseph Schoepf; Philipp Blanke; J Reid Spears; Garrett W Rowe; William T Halligan; Thomas Henzler; Fabian Bamberg; Alexander W Leber; Ellen Hoffmann; Paul Apfaltrer
Journal:  Eur Radiol       Date:  2012-07-10       Impact factor: 5.315

2.  Impact of iterative reconstruction on CNR and SNR in dynamic myocardial perfusion imaging in an animal model.

Authors:  B M Gramer; D Muenzel; V Leber; A-K von Thaden; H Feussner; A Schneider; M Vembar; N Soni; E J Rummeny; A M Huber
Journal:  Eur Radiol       Date:  2012-07-03       Impact factor: 5.315

3.  Image quality and dose optimisation for infant CT using a paediatric phantom.

Authors:  Jack W Lambert; Andrew S Phelps; Jesse L Courtier; Robert G Gould; John D MacKenzie
Journal:  Eur Radiol       Date:  2015-08-26       Impact factor: 5.315

4.  Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT.

Authors:  F Gay; Y Pavia; N Pierrat; S Lasalle; S Neuenschwander; H J Brisse
Journal:  Eur Radiol       Date:  2013-08-31       Impact factor: 5.315

Review 5.  Advances in stress cardiac MRI and computed tomography.

Authors:  Yasmin S Hamirani; Christopher M Kramer
Journal:  Future Cardiol       Date:  2013-09

6.  Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose.

Authors:  Chien-Ming Chen; Sung-Yu Chu; Ming-Yi Hsu; Ying-Lan Liao; Hui-Yu Tsai
Journal:  Eur Radiol       Date:  2013-10-02       Impact factor: 5.315

7.  Low-dose CT screening using hybrid iterative reconstruction: confidence ratings of diagnoses of simulated lesions other than lung cancer.

Authors:  N Sakai; H Yabuuchi; M Kondo; Y Matsuo; T Kamitani; M Nagao; M Jinnouchi; M Yonezawa; T Kojima; Y Yano; H Honda
Journal:  Br J Radiol       Date:  2015-07-08       Impact factor: 3.039

8.  Deep Auto-context Convolutional Neural Networks for Standard-Dose PET Image Estimation from Low-Dose PET/MRI.

Authors:  Lei Xiang; Yu Qiao; Dong Nie; Le An; Qian Wang; Dinggang Shen
Journal:  Neurocomputing       Date:  2017-06-29       Impact factor: 5.719

9.  Optimization of computed tomography (CT) arthrography of hip for the visualization of cartilage: an in vitro study.

Authors:  Paolo Simoni; Pierre-Philippe Leyder; Adelin Albert; Françoise Malchair; Carole Maréchal; Laura Scarciolla; Bruno Beomonte Zobel; Victoria Alvarez Miezentseva; Philippe Gillet
Journal:  Skeletal Radiol       Date:  2013-11-27       Impact factor: 2.199

Review 10.  Pediatric CT: strategies to lower radiation dose.

Authors:  Claudia Zacharias; Adam M Alessio; Randolph K Otto; Ramesh S Iyer; Grace S Philips; Jonathan O Swanson; Mahesh M Thapa
Journal:  AJR Am J Roentgenol       Date:  2013-05       Impact factor: 3.959

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.