Literature DB >> 21921764

Preoperative vascular mapping for facial allotransplantation: four-dimensional computed tomographic angiography versus magnetic resonance angiography.

Shigeyoshi Soga1, Bohdan Pomahac, Dimitrios Mitsouras, Kanako Kumamaru, Sara L Powers, Richard F Prior, Jason Signorelli, Ericka M Bueno, Michael L Steigner, Frank J Rybicki.   

Abstract

BACKGROUND: Facial allotransplantation requires a detailed arterial and venous assessment for surgical planning. Target vessels are often depleted by multiple reconstructive attempts or the severe facial injury itself. The purpose of this study was to retrospectively compare the diagnostic performance of computed tomography and magnetic resonance angiography in the preoperative assessment.
METHODS: Four-dimensional (three spatial planes plus time) computed tomographic and magnetic resonance images including 126 potential vessels (76 arteries and 50 veins) from five candidates were analyzed independently by two radiologists using a four-point image quality scale. Computed tomographic versus magnetic resonance image quality was compared directly, using a computed tomographic angiography consensus read as reference standard. Vessels with metal artifact on magnetic resonance imaging, computed tomography, or both underwent separate analyses to determine the impact of metal implants on image quality.
RESULTS: Considering all 126 vessels, the mean computed tomographic image quality was superior to that of magnetic resonance angiography. When considering individual vessels, all except for major neck vessels were better visualized by computed tomography. Images of 26 vessels were degraded by metal artifact; magnetic resonance image quality was inferior for those vessels. Considering images of major vessels with no metal artifact, there was no significant mean image quality difference between computed tomography and magnetic resonance imaging.
CONCLUSIONS: Computed tomographic angiography should be used as the first-choice modality for preoperative imaging of facial transplant patients because, when compared with magnetic resonance imaging, the visualization of small vessels is far superior and images have fewer artifacts. CLINICAL QUESTION/LEVEL OF EVIDENCE: Diagnostic, II.

Entities:  

Mesh:

Year:  2011        PMID: 21921764     DOI: 10.1097/PRS.0b013e3182268b43

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  9 in total

Review 1.  Medical 3D Printing for the Radiologist.

Authors:  Dimitris Mitsouras; Peter Liacouras; Amir Imanzadeh; Andreas A Giannopoulos; Tianrun Cai; Kanako K Kumamaru; Elizabeth George; Nicole Wake; Edward J Caterson; Bohdan Pomahac; Vincent B Ho; Gerald T Grant; Frank J Rybicki
Journal:  Radiographics       Date:  2015 Nov-Dec       Impact factor: 5.333

Review 2.  CT angiography for surgical planning in face transplantation candidates.

Authors:  S Soga; B Pomahac; N Wake; K Schultz; R F Prior; K Kumamaru; M L Steigner; D Mitsouras; J Signorelli; E M Bueno; D S Enterline; F J Rybicki
Journal:  AJNR Am J Neuroradiol       Date:  2012-08-09       Impact factor: 3.825

Review 3.  Development and refinement of computer-assisted planning and execution system for use in face-jaw-teeth transplantation to improve skeletal and dento-occlusal outcomes.

Authors:  Sepehr Hashemi; Mehran Armand; Chad R Gordon
Journal:  Curr Opin Organ Transplant       Date:  2016-10       Impact factor: 2.640

4.  Face transplant perfusion assessment using near-infrared fluorescence imaging.

Authors:  John T Nguyen; Yoshitomo Ashitate; Ian A Buchanan; Ahmed M S Ibrahim; Sylvain Gioux; Priti P Patel; John V Frangioni; Bernard T Lee
Journal:  J Surg Res       Date:  2012-04-27       Impact factor: 2.192

5.  Noninvasive vascular images for face transplant surgical planning.

Authors:  Shigeyoshi Soga; Nicole Wake; Ericka M Bueno; Michael L Steigner; Dimitrios Mitsouras; Kurt Schultz; J Rodrigo Diaz-Siso; Geoffroy C Sisk; Richard Prior; Sara L Powers; Jason Signorelli; Camille K Jania; Bohdan Pomahac; Frank J Rybicki
Journal:  Eplasty       Date:  2011-12-14

6.  Facial Reconstruction: A Systematic Review of Current Image Acquisition and Processing Techniques.

Authors:  Sam P Tarassoli; Matthew E Shield; Rhian S Allen; Zita M Jessop; Thomas D Dobbs; Iain S Whitaker
Journal:  Front Surg       Date:  2020-12-07

7.  Cine computed tomography angiography evaluation of blood flow for full face transplant surgical planning.

Authors:  Geoffroy C Sisk; Kanako K Kumamaru; Kurt Schultz; Ericka M Bueno; J Rodrigo Diaz-Siso; Elizabeth George; Marta M Redjaee; Dimitrios Mitsouras; Michael L Steigner; Bohdan Pomahac; Frank J Rybicki
Journal:  Eplasty       Date:  2012-12-18

8.  Reduced radiation exposure for face transplant surgical planning computed tomography angiography.

Authors:  Kurt Schultz; Elizabeth George; Katherine M Mullen; Michael L Steigner; Dimitrios Mitsouras; Ericka M Bueno; Bohdan Pomahac; Frank J Rybicki; Kanako K Kumamaru
Journal:  PLoS One       Date:  2013-04-26       Impact factor: 3.240

9.  Upper extremity composite tissue allotransplantation imaging.

Authors:  Elizabeth George; Dimitrios Mitsouras; Kanako K Kumamaru; Nehal Shah; Stacy E Smith; Kurt Schultz; Pamela M Deaver; Katherine M Mullen; Michael L Steigner; Edwin C Gravereaux; Shadpour Demehri; Ericka M Bueno; Simon G Talbot; Bohdan Pomahac; Frank J Rybicki
Journal:  Eplasty       Date:  2013-07-16
  9 in total