Literature DB >> 23571679

A reference dataset for deformable image registration spatial accuracy evaluation using the COPDgene study archive.

Richard Castillo1, Edward Castillo, David Fuentes, Moiz Ahmad, Abbie M Wood, Michelle S Ludwig, Thomas Guerrero.   

Abstract

Landmark point-pairs provide a strategy to assess deformable image registration (DIR) accuracy in terms of the spatial registration of the underlying anatomy depicted in medical images. In this study, we propose to augment a publicly available database (www.dir-lab.com) of medical images with large sets of manually identified anatomic feature pairs between breath-hold computed tomography (BH-CT) images for DIR spatial accuracy evaluation. Ten BH-CT image pairs were randomly selected from the COPDgene study cases. Each patient had received CT imaging of the entire thorax in the supine position at one-fourth dose normal expiration and maximum effort full dose inspiration. Using dedicated in-house software, an imaging expert manually identified large sets of anatomic feature pairs between images. Estimates of inter- and intra-observer spatial variation in feature localization were determined by repeat measurements of multiple observers over subsets of randomly selected features. 7298 anatomic landmark features were manually paired between the 10 sets of images. Quantity of feature pairs per case ranged from 447 to 1172. Average 3D Euclidean landmark displacements varied substantially among cases, ranging from 12.29 (SD: 6.39) to 30.90 (SD: 14.05) mm. Repeat registration of uniformly sampled subsets of 150 landmarks for each case yielded estimates of observer localization error, which ranged in average from 0.58 (SD: 0.87) to 1.06 (SD: 2.38) mm for each case. The additions to the online web database (www.dir-lab.com) described in this work will broaden the applicability of the reference data, providing a freely available common dataset for targeted critical evaluation of DIR spatial accuracy performance in multiple clinical settings. Estimates of observer variance in feature localization suggest consistent spatial accuracy for all observers across both four-dimensional CT and COPDgene patient cohorts.

Entities:  

Mesh:

Year:  2013        PMID: 23571679      PMCID: PMC3677192          DOI: 10.1088/0031-9155/58/9/2861

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  38 in total

1.  A method to evaluate dose errors introduced by dose mapping processes for mass conserving deformations.

Authors:  C Yan; G Hugo; F J Salguero; N Saleh-Sayah; E Weiss; W C Sleeman; J V Siebers
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Computation of 3-D velocity fields from 3-D cine CT images of a human heart.

Authors:  S M Song; R M Leahy
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

Review 3.  Principles of CT: radiation dose and image quality.

Authors:  Lee W Goldman
Journal:  J Nucl Med Technol       Date:  2007-11-15

4.  Quantitative CT in chronic obstructive pulmonary disease: inspiratory and expiratory assessment.

Authors:  Masanori Akira; Kazushige Toyokawa; Yoshikazu Inoue; Toru Arai
Journal:  AJR Am J Roentgenol       Date:  2009-01       Impact factor: 3.959

5.  Chronic obstructive pulmonary disease: a view from the NHLBI.

Authors:  Antonello Punturieri; Thomas L Croxton; Gail G Weinmann; James P Kiley
Journal:  Am J Respir Crit Care Med       Date:  2008-09-01       Impact factor: 21.405

6.  Evaluation of registration methods on thoracic CT: the EMPIRE10 challenge.

Authors:  Keelin Murphy; Bram van Ginneken; Joseph M Reinhardt; Sven Kabus; Kai Ding; Xiang Deng; Kunlin Cao; Kaifang Du; Gary E Christensen; Vincent Garcia; Tom Vercauteren; Nicholas Ayache; Olivier Commowick; Grégoire Malandain; Ben Glocker; Nikos Paragios; Nassir Navab; Vladlena Gorbunova; Jon Sporring; Marleen de Bruijne; Xiao Han; Mattias P Heinrich; Julia A Schnabel; Mark Jenkinson; Cristian Lorenz; Marc Modat; Jamie R McClelland; Sébastien Ourselin; Sascha E A Muenzing; Max A Viergever; Dante De Nigris; D Louis Collins; Tal Arbel; Marta Peroni; Rui Li; Gregory C Sharp; Alexander Schmidt-Richberg; Jan Ehrhardt; René Werner; Dirk Smeets; Dirk Loeckx; Gang Song; Nicholas Tustison; Brian Avants; James C Gee; Marius Staring; Stefan Klein; Berend C Stoel; Martin Urschler; Manuel Werlberger; Jef Vandemeulebroucke; Simon Rit; David Sarrut; Josien P W Pluim
Journal:  IEEE Trans Med Imaging       Date:  2011-05-31       Impact factor: 10.048

7.  Analytic regularization for landmark-based image registration.

Authors:  Nadezhda Shusharina; Gregory Sharp
Journal:  Phys Med Biol       Date:  2012-03-05       Impact factor: 3.609

8.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

Authors:  Yvette Seppenwoolde; Hiroki Shirato; Kei Kitamura; Shinichi Shimizu; Marcel van Herk; Joos V Lebesque; Kazuo Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-07-15       Impact factor: 7.038

9.  4D-CT lung motion estimation with deformable registration: quantification of motion nonlinearity and hysteresis.

Authors:  Vlad Boldea; Gregory C Sharp; Steve B Jiang; David Sarrut
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

10.  Validation of deformable registration in head and neck cancer using analysis of variance.

Authors:  A Mencarelli; S van Beek; S van Kranen; C Rasch; M van Herk; J-J Sonke
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

View more
  22 in total

1.  Quadratic penalty method for intensity-based deformable image registration and 4DCT lung motion recovery.

Authors:  Edward Castillo
Journal:  Med Phys       Date:  2019-03-14       Impact factor: 4.071

2.  Error estimation of deformable image registration of pulmonary CT scans using convolutional neural networks.

Authors:  Koen A J Eppenhof; Josien P W Pluim
Journal:  J Med Imaging (Bellingham)       Date:  2018-05-10

3.  Computing global minimizers to a constrained B-spline image registration problem from optimal l1 perturbations to block match data.

Authors:  Edward Castillo; Richard Castillo; David Fuentes; Thomas Guerrero
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

4.  Morphometry-based measurements of the structural response to whole-brain radiation.

Authors:  D Fuentes; J Contreras; J Yu; R He; E Castillo; R Castillo; T Guerrero
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-11-20       Impact factor: 2.924

5.  Multi-modal and multi-vendor retina image registration.

Authors:  Zhang Li; Fan Huang; Jiong Zhang; Behdad Dashtbozorg; Samaneh Abbasi-Sureshjani; Yue Sun; Xi Long; Qifeng Yu; Bart Ter Haar Romeny; Tao Tan
Journal:  Biomed Opt Express       Date:  2018-01-03       Impact factor: 3.732

6.  Discontinuity Preserving Liver MR Registration with 3D Active Contour Motion Segmentation.

Authors:  Dongxiao Li; Wenxiong Zhong; Kofi M Deh; Thanh Nguyen; Martin R Prince; Yi Wang; Pascal Spincemaille
Journal:  IEEE Trans Biomed Eng       Date:  2018-11-12       Impact factor: 4.538

7.  A hybrid optimization strategy for registering images with large local deformations and intensity variations.

Authors:  Zhang Li; Lucas J van Vliet; Jaap Stoker; Frans M Vos
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-12-30       Impact factor: 2.924

8.  Quantitative assessment of target delineation variability for thymic cancers: Agreement evaluation of a prospective segmentation challenge.

Authors:  Emma Holliday; Clifton D Fuller; Jayashree Kalpathy-Cramer; Daniel Gomez; Andreas Rimner; Ying Li; Suresh Senan; Lynn D Wilson; Jehee Choi; Ritsuko Komaki; Charles R Thomas
Journal:  J Radiat Oncol       Date:  2015-11-03

9.  Iterative inversion of deformation vector fields with feedback control.

Authors:  Abhishek Dubey; Alexandros-Stavros Iliopoulos; Xiaobai Sun; Fang-Fang Yin; Lei Ren
Journal:  Med Phys       Date:  2018-06-10       Impact factor: 4.071

Review 10.  Adaptive Radiation Therapy (ART) Strategies and Technical Considerations: A State of the ART Review From NRG Oncology.

Authors:  Carri K Glide-Hurst; Percy Lee; Adam D Yock; Jeffrey R Olsen; Minsong Cao; Farzan Siddiqui; William Parker; Anthony Doemer; Yi Rong; Amar U Kishan; Stanley H Benedict; X Allen Li; Beth A Erickson; Jason W Sohn; Ying Xiao; Evan Wuthrick
Journal:  Int J Radiat Oncol Biol Phys       Date:  2020-10-24       Impact factor: 7.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.