Literature DB >> 19098209

Quantitative CT in chronic obstructive pulmonary disease: inspiratory and expiratory assessment.

Masanori Akira1, Kazushige Toyokawa, Yoshikazu Inoue, Toru Arai.   

Abstract

OBJECTIVE: The purpose of this study was to determine whether measurements of lung attenuation at inspiration and expiration obtained from 3D lung reconstructions reflect the severity of chronic obstructive pulmonary disease. SUBJECTS AND METHODS: Seventy-six patients with chronic obstructive pulmonary disease underwent MDCT with 3D postprocessing at full inspiration and full expiration. Inspiratory and expiratory mean lung density, percentage of lung volume with attenuation values less than -910 HU and -950 HU at inspiration and expiration, expiratory to inspiratory mean lung density ratio, and fifth and 15th percentiles of the lung attenuation distribution curve at inspiration and expiration were measured.
RESULTS: When forced expiratory volume in the first second of expiration (FEV(1)) was 50% or greater than predicted value, mean lung density and lower attenuation volume measured from inspiratory MDCT scans correlated better with FEV(1) and ratio of FEV(1) to forced vital capacity (FVC) than did those from expiratory scans. When FEV(1) was less than 50% of predicted value, mean lung density and lower attenuation volume measured from expiratory MDCT scans correlated better with FEV(1) and ratio of residual volume to total lung capacity than did those values from inspiratory scans. Fifth percentile and 15th percentile of the lung attenuation distribution curve at both full inspiration and full expiration correlated well with FEV(1)/FVC and diffusing capacity of the lung for carbon monoxide as a percentage of predicted value but not well with FEV(1) as a percentage of predicted value regardless of FEV(1).
CONCLUSION: Measurements of lung attenuation obtained at inspiration and visual score better reflect abnormal results of pulmonary function tests in patients with less severe chronic obstructive pulmonary disease than do measurements obtained at expiration. Measurements of lung attenuation obtained at expiration better reflect pulmonary function abnormalities in patients with severe chronic obstructive pulmonary disease.

Entities:  

Mesh:

Year:  2009        PMID: 19098209     DOI: 10.2214/AJR.07.3953

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  23 in total

1.  Spirometric and radiological evaluation of the remnant lung long after major pulmonary resection: can compensatory phenomena be recognized in clinical cases?

Authors:  Teruaki Mizobuchi; Hironobu Wada; Yuichi Sakairi; Hidemi Suzuki; Takahiro Nakajima; Tetsuzo Tagawa; Takekazu Iwata; Ken Motoori; Shigetoshi Yoshida; Ichiro Yoshino
Journal:  Surg Today       Date:  2013-08-27       Impact factor: 2.549

2.  Optimal threshold of subtraction method for quantification of air-trapping on coregistered CT in COPD patients.

Authors:  Sang Min Lee; Joon Beom Seo; Sang Min Lee; Namkug Kim; Sang Young Oh; Yeon-Mok Oh
Journal:  Eur Radiol       Date:  2015-10-29       Impact factor: 5.315

Review 3.  Advances in Imaging and Automated Quantification of Pulmonary Diseases in Non-neoplastic Diseases.

Authors:  Fernanda Balbinot; Álvaro da Costa Batista Guedes; Douglas Zaione Nascimento; Juliana Fischman Zampieri; Giordano Rafael Tronco Alves; Edson Marchiori; Adalberto Sperb Rubin; Bruno Hochhegger
Journal:  Lung       Date:  2016-09-23       Impact factor: 2.584

4.  Correlation Between Emphysema and Lung Function in Healthy Smokers and Smokers With COPD.

Authors:  Laura H Thomsen; Saher B Shaker; Asger Dirksen; Jesper H Pedersen; Ruth Tal-Singer; Per Bakke; Jørgen Vestbo
Journal:  Chronic Obstr Pulm Dis       Date:  2015-05-19

Review 5.  CT protocols in interstitial lung diseases--a survey among members of the European Society of Thoracic Imaging and a review of the literature.

Authors:  Helmut Prosch; Cornelia M Schaefer-Prokop; Edith Eisenhuber; Daniela Kienzl; Christian J Herold
Journal:  Eur Radiol       Date:  2012-12-13       Impact factor: 5.315

6.  Repeatability and Sample Size Assessment Associated with Computed Tomography-Based Lung Density Metrics.

Authors:  Krishna S Iyer; Randall W Grout; Gideon K Zamba; Eric A Hoffman
Journal:  Chronic Obstr Pulm Dis       Date:  2014

7.  Assessment of lung volume collapsibility in chronic obstructive lung disease patients using CT.

Authors:  Shinjini Kundu; Suicheng Gu; Joseph K Leader; John R Tedrow; Frank C Sciurba; David Gur; Naftali Kaminski; Jiantao Pu
Journal:  Eur Radiol       Date:  2013-03-15       Impact factor: 5.315

8.  Fully automatic quantitative assessment of emphysema in computed tomography: comparison with pulmonary function testing and normal values.

Authors:  C P Heussel; F J F Herth; J Kappes; R Hantusch; S Hartlieb; O Weinheimer; H U Kauczor; R Eberhardt
Journal:  Eur Radiol       Date:  2009-05-21       Impact factor: 5.315

9.  Detailed analysis of the density change on chest CT of COPD using non-rigid registration of inspiration/expiration CT scans.

Authors:  Eun Young Kim; Joon Beom Seo; Hyun Joo Lee; Namkug Kim; Eunsol Lee; Sang Min Lee; Sang Young Oh; Hye Jeon Hwang; Yeon-Mok Oh; Sang-Do Lee
Journal:  Eur Radiol       Date:  2014-09-14       Impact factor: 5.315

10.  Collapsibility of lung volume by paired inspiratory and expiratory CT scans: correlations with lung function and mean lung density.

Authors:  Tsuneo Yamashiro; Shin Matsuoka; Brian J Bartholmai; Raúl San José Estépar; James C Ross; Alejandro Diaz; Sadayuki Murayama; Edwin K Silverman; Hiroto Hatabu; George R Washko
Journal:  Acad Radiol       Date:  2010-01-12       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.