Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

Yvette Seppenwoolde1, Hiroki Shirato, Kei Kitamura, Shinichi Shimizu, Marcel van Herk, Joos V Lebesque, Kazuo Miyasaka.   

Abstract

PURPOSE: In this work, three-dimensional (3D) motion of lung tumors during radiotherapy in real time was investigated. Understanding the behavior of tumor motion in lung tissue to model tumor movement is necessary for accurate (gated or breath-hold) radiotherapy or CT scanning.
METHODS: Twenty patients were included in this study. Before treatment, a 2-mm gold marker was implanted in or near the tumor. A real-time tumor tracking system using two fluoroscopy image processor units was installed in the treatment room. The 3D position of the implanted gold marker was determined by using real-time pattern recognition and a calibrated projection geometry. The linear accelerator was triggered to irradiate the tumor only when the gold marker was located within a certain volume. The system provided the coordinates of the gold marker during beam-on and beam-off time in all directions simultaneously, at a sample rate of 30 images per second. The recorded tumor motion was analyzed in terms of the amplitude and curvature of the tumor motion in three directions, the differences in breathing level during treatment, hysteresis (the difference between the inhalation and exhalation trajectory of the tumor), and the amplitude of tumor motion induced by cardiac motion.
RESULTS: The average amplitude of the tumor motion was greatest (12 +/- 2 mm [SD]) in the cranial-caudal direction for tumors situated in the lower lobes and not attached to rigid structures such as the chest wall or vertebrae. For the lateral and anterior-posterior directions, tumor motion was small both for upper- and lower-lobe tumors (2 +/- 1 mm). The time-averaged tumor position was closer to the exhale position, because the tumor spent more time in the exhalation than in the inhalation phase. The tumor motion was modeled as a sinusoidal movement with varying asymmetry. The tumor position in the exhale phase was more stable than the tumor position in the inhale phase during individual treatment fields. However, in many patients, shifts in the exhale tumor position were observed intra- and interfractionally. These shifts are the result of patient relaxation, gravity (posterior direction), setup errors, and/or patient movement.The 3D trajectory of the tumor showed hysteresis for 10 of the 21 tumors, which ranged from 1 to 5 mm. The extent of hysteresis and the amplitude of the tumor motion remained fairly constant during the entire treatment. Changes in shape of the trajectory of the tumor were observed between subsequent treatment days for only one patient. Fourier analysis revealed that for 7 of the 21 tumors, a measurable motion in the range 1-4 mm was caused by the cardiac beat. These tumors were located near the heart or attached to the aortic arch. The motion due to the heartbeat was greatest in the lateral direction. Tumor motion due to hysteresis and heartbeat can lower treatment efficiency in real-time tumor tracking-gated treatments or lead to a geographic miss in conventional or active breathing controlled treatments.
CONCLUSION: The real-time tumor tracking system measured the tumor position in all three directions simultaneously, at a sampling rate that enabled detection of tumor motion due to heartbeat as well as hysteresis. Tumor motion and hysteresis could be modeled with an asymmetric function with varying asymmetry. Tumor motion due to breathing was greatest in the cranial-caudal direction for lower-lobe unfixed tumors.

Entities:  

Mesh:

Year:  2002        PMID: 12095547     DOI: 10.1016/s0360-3016(02)02803-1

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  281 in total

Review 1.  Imaging and image-guided radiation therapy in liver cancer.

Authors:  Kristy K Brock
Journal:  Semin Radiat Oncol       Date:  2011-10       Impact factor: 5.934

2.  Biomechanical interpretation of a free-breathing lung motion model.

Authors:  Tianyu Zhao; Benjamin White; Kevin L Moore; James Lamb; Deshan Yang; Wei Lu; Sasa Mutic; Daniel A Low
Journal:  Phys Med Biol       Date:  2011-11-11       Impact factor: 3.609

3.  Online monitoring and error detection of real-time tumor displacement prediction accuracy using control limits on respiratory surrogate statistics.

Authors:  Kathleen Malinowski; Thomas J McAvoy; Rohini George; Sonja Dieterich; Warren D D'Souza
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

4.  A novel technique for markerless, self-sorted 4D-CBCT: feasibility study.

Authors:  Irina Vergalasova; Jing Cai; Fang-Fang Yin
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

5.  The dosimetric impact of inversely optimized arc radiotherapy plan modulation for real-time dynamic MLC tracking delivery.

Authors:  Marianne Falk; Tobias Larsson; Paul Keall; Byung Chul Cho; Marianne Aznar; Stine Korreman; Per Poulsen; Per Munck Af Rosenschold
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

6.  Design of a compensating bolus by use of exhalation CT data for covering residual motion in respiratory-gated charged-particle lung therapy: four-dimensional carbon beam dose calculation.

Authors:  Shinichiro Mori; Hiroshi Asakura; Shuhei Komatsu; Tomoyasu Yashiro; Motoki Kumagai; Susumu Kandatsu; Masayuki Baba; Masahiro Endo
Journal:  Radiol Phys Technol       Date:  2007-11-27

7.  Sequential dual-energy subtraction technique with a dynamic flat-panel detector (FPD): primary study for image-guided radiation therapy (IGRT).

Authors:  Rie Tanaka; Shigeru Sanada; Takeshi Matsui; Norio Hayashi; Osamu Matsui
Journal:  Radiol Phys Technol       Date:  2008-04-10

8.  Volumetric tracking tool using four-dimensional CT for image guided-radiation therapy.

Authors:  Rie Tanaka; Shinichiro Mori; Masahiro Endo; Shigeru Sanada
Journal:  Radiol Phys Technol       Date:  2007-11-13

9.  Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements.

Authors:  Kaifang Du; Joseph M Reinhardt; Gary E Christensen; Kai Ding; John E Bayouth
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

10.  A simplified method of four-dimensional dose accumulation using the mean patient density representation.

Authors:  Carri K Glide-Hurst; Geoffrey D Hugo; Jian Liang; Di Yan
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.