Literature DB >> 30801729

Quadratic penalty method for intensity-based deformable image registration and 4DCT lung motion recovery.

Edward Castillo1,2.   

Abstract

Intensity-based deformable image registration (DIR) requires minimizing an image dissimilarity metric. Imaged anatomy, such as bones and vasculature, as well as the resolution of the digital grid, can often cause discontinuities in the corresponding objective function. Consequently, the application of a gradient-based optimization algorithm requires a preprocessing image smoothing to ensure the existence of necessary image derivatives. Simple block matching (exhaustive search) methods do not require image derivative approximations, but their general effectiveness is often hindered by erroneous solutions (outliers). Block match methods are therefore often coupled with a statistical outlier detection method to improve results.
PURPOSE: The purpose of this work is to present a spatially accurate, intensity-based DIR optimization formulation that can be solved with a straightforward gradient-free quadratic penalty algorithm and is suitable for 4D thoracic computed tomography (4DCT) registration. Additionally, a novel regularization strategy based on the well-known leave-one-out robust statistical model cross-validation method is introduced.
METHODS: The proposed Quadratic Penalty DIR (QPDIR) method minimizes both an image dissimilarity term, which is separable with respect to individual voxel displacements, and a regularization term derived from the classical leave-one-out cross-validation statistical method. The resulting DIR problem lends itself to a quadratic penalty function optimization approach, where each subproblem can be solved by straightforward block coordinate descent iteration.
RESULTS: The spatial accuracy of the method was assessed using expert-determined landmarks on ten 4DCT datasets available on www.dir-lab.com. The QPDIR algorithm achieved average millimeter spatial errors between 0.69 (0.91) and 1.19 (1.26) on the ten test cases. On all ten 4DCT test cases, the QPDIR method produced spatial accuracies that are superior or equivalent to those produced by current state-of-the-art methods. Moreover, QPDIR achieved accuracies at the resolution of the landmark error assessment (i.e., the interobserver error) on six of the ten cases.
CONCLUSION: The QPDIR algorithm is based on a simple quadratic penalty function formulation and a regularization term inspired by leave-one-out cross validation. The formulation lends itself to a parallelizable, gradient-free, block coordinate descent numerical optimization method. Numerical results indicate that the method achieves a high spatial accuracy on 4DCT inhale/exhale phases.
© 2019 American Association of Physicists in Medicine.

Entities:  

Keywords:  deformable image registration; four-dimensional computed tomography; landmark validation; lung motion; moving least squares; numerical optimization

Mesh:

Year:  2019        PMID: 30801729      PMCID: PMC6510611          DOI: 10.1002/mp.13457

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  23 in total

1.  Improved optimization for the robust and accurate linear registration and motion correction of brain images.

Authors:  Mark Jenkinson; Peter Bannister; Michael Brady; Stephen Smith
Journal:  Neuroimage       Date:  2002-10       Impact factor: 6.556

2.  Image quality assessment: from error visibility to structural similarity.

Authors:  Zhou Wang; Alan Conrad Bovik; Hamid Rahim Sheikh; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2004-04       Impact factor: 10.856

3.  Ventilation from four-dimensional computed tomography: density versus Jacobian methods.

Authors:  Richard Castillo; Edward Castillo; Josue Martinez; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2010-07-30       Impact factor: 3.609

4.  A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets.

Authors:  Richard Castillo; Edward Castillo; Rudy Guerra; Valen E Johnson; Travis McPhail; Amit K Garg; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

5.  Toward efficient biomechanical-based deformable image registration of lungs for image-guided radiotherapy.

Authors:  Adil Al-Mayah; Joanne Moseley; Mike Velec; Kristy Brock
Journal:  Phys Med Biol       Date:  2011-07-06       Impact factor: 3.609

6.  Four-dimensional deformable image registration using trajectory modeling.

Authors:  Edward Castillo; Richard Castillo; Josue Martinez; Maithili Shenoy; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

7.  4D-CT lung motion estimation with deformable registration: quantification of motion nonlinearity and hysteresis.

Authors:  Vlad Boldea; Gregory C Sharp; Steve B Jiang; David Sarrut
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

8.  Patient-specific finite element modeling of respiratory lung motion using 4D CT image data.

Authors:  René Werner; Jan Ehrhardt; Rainer Schmidt; Heinz Handels
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

9.  Contact surface and material nonlinearity modeling of human lungs.

Authors:  A Al-Mayah; J Moseley; K K Brock
Journal:  Phys Med Biol       Date:  2007-12-19       Impact factor: 3.609

10.  Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration.

Authors:  Arno Klein; Jesper Andersson; Babak A Ardekani; John Ashburner; Brian Avants; Ming-Chang Chiang; Gary E Christensen; D Louis Collins; James Gee; Pierre Hellier; Joo Hyun Song; Mark Jenkinson; Claude Lepage; Daniel Rueckert; Paul Thompson; Tom Vercauteren; Roger P Woods; J John Mann; Ramin V Parsey
Journal:  Neuroimage       Date:  2009-01-13       Impact factor: 6.556

View more
  6 in total

1.  Automatic large quantity landmark pairs detection in 4DCT lung images.

Authors:  Yabo Fu; Xue Wu; Allan M Thomas; Harold H Li; Deshan Yang
Journal:  Med Phys       Date:  2019-08-07       Impact factor: 4.071

2.  Image registration method using representative feature detection and iterative coherent spatial mapping for infrared medical images with flat regions.

Authors:  Hao-Jen Wang; Chia-Yen Lee; Jhih-Hao Lai; Yeun-Chung Chang; Chung-Ming Chen
Journal:  Sci Rep       Date:  2022-05-13       Impact factor: 4.996

3.  Robust HU-based CT ventilation from an integrated mass conservation formulation.

Authors:  Edward Castillo; Yevgeniy Vinogradskiy; Richard Castillo
Journal:  Med Phys       Date:  2019-09-28       Impact factor: 4.071

4.  Functional avoidance-based intensity modulated proton therapy with 4DCT derived ventilation imaging for lung cancer.

Authors:  Jingjing M Dougherty; Edward Castillo; Richard Castillo; Austin M Faught; Mark Pepin; Sean S Park; Chris J Beltran; Thomas Guerrero; Inga Grills; Yevgeniy Vinogradskiy
Journal:  J Appl Clin Med Phys       Date:  2021-06-22       Impact factor: 2.102

5.  Technical Note: On the spatial correlation between robust CT-ventilation methods and SPECT ventilation.

Authors:  Edward Castillo; Richard Castillo; Yevgeniy Vinogradskiy; Girish Nair; Inga Grills; Thomas Guerrero; Craig Stevens
Journal:  Med Phys       Date:  2020-10-17       Impact factor: 4.071

6.  Geometric and dosimetric accuracy of deformable image registration between average-intensity images for 4DCT-based adaptive radiotherapy for non-small cell lung cancer.

Authors:  Yulun He; Guillaume Cazoulat; Carol Wu; Christine Peterson; Molly McCulloch; Brian Anderson; Julianne Pollard-Larkin; Peter Balter; Zhongxing Liao; Radhe Mohan; Kristy Brock
Journal:  J Appl Clin Med Phys       Date:  2021-07-26       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.