Literature DB >> 23512603

Evaluation of the accuracy of femoral component orientation by the CT-based fluoro-matched navigation system.

Shinya Hayashi1, Takayuki Nishiyama, Takaaki Fujishiro, Shingo Hashimoto, Noriyuki Kanzaki, Kotaro Nishida, Ryosuke Kuroda, Masahiro Kurosaka.   

Abstract

PURPOSE: Accurate orientation of acetabular and femoral components are important during THA. However, no study has assessed the use of the CT-based fluoro-matched navigation system during THA. Therefore, we have evaluated the accuracy of stem orientation by CT-based fluoro-matched navigation.
METHODS: The accuracy of stem orientation by CT-based fluoro-matched navigation was assessed by postoperative CT data. Furthermore, we compared the postoperative stem orientation with the intraoperative registration errors.
RESULTS: The average antetorsion error of the stem (navigation records - postoperative CT) was -0.5° ± 5.2°. The stem valgus error was 0.4° ± 2.7°. The accuracy of the navigation record for the orientation of the stem valgus was dependent on the intraoperative registration errors.
CONCLUSIONS: The clinical accuracy of CT-based fluoro-matched navigation is adequate for stem alignment orientation, and the intraoperative verification of registration errors is valuable for checking the accuracy of stem orientation by navigation.

Mesh:

Year:  2013        PMID: 23512603      PMCID: PMC3664150          DOI: 10.1007/s00264-013-1852-2

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  16 in total

1.  Computer assisted implantation of the femoral stem in THA - an experimental study.

Authors:  J Jerosch; E Peuker; C von Hasselbach; A Lahmer; T Filler; U Witzel
Journal:  Int Orthop       Date:  1999       Impact factor: 3.075

2.  Anterior pelvic soft tissue thickness influences acetabular cup positioning with imageless navigation.

Authors:  Erik Hohmann; Adam Bryant; Kevin Tetsworth
Journal:  J Arthroplasty       Date:  2011-10-29       Impact factor: 4.757

3.  Total hip arthroplasty through a minimal posterior approach using imageless computer-assisted hip navigation.

Authors:  Richard L Wixson; Margot A MacDonald
Journal:  J Arthroplasty       Date:  2005-10       Impact factor: 4.757

4.  Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation?

Authors:  T Kalteis; M Handel; H Bäthis; L Perlick; M Tingart; J Grifka
Journal:  J Bone Joint Surg Br       Date:  2006-02

5.  Error in acetabular socket alignment due to the thick anterior pelvic soft tissues.

Authors:  Yeon Soo Lee; Taek Rim Yoon
Journal:  J Arthroplasty       Date:  2007-08-01       Impact factor: 4.757

6.  Combined anteversion technique for total hip arthroplasty.

Authors:  Lawrence D Dorr; Aamer Malik; Manish Dastane; Zhinian Wan
Journal:  Clin Orthop Relat Res       Date:  2008-11-01       Impact factor: 4.176

7.  Computed tomography measurement of the accuracy of component version in total hip arthroplasty.

Authors:  Andrew P Wines; David McNicol
Journal:  J Arthroplasty       Date:  2006-08       Impact factor: 4.757

8.  [Increasing the quality of preoperative planning and intraoperative application of computer-assisted systems and surgical robots--an experimental study].

Authors:  J Jerosch; C von Hasselbach; T Filler; E Peuker; M Rahgozar; A Lahmer
Journal:  Chirurg       Date:  1998-09       Impact factor: 0.955

9.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

10.  Evaluation of component positioning in primary total hip arthroplasty using an imageless navigation device compared with traditional methods.

Authors:  Brian C Najarian; John E Kilgore; David C Markel
Journal:  J Arthroplasty       Date:  2008-04-03       Impact factor: 4.757

View more
  10 in total

1.  The effect of acetabular and femoral component version on dislocation in primary total hip arthroplasty.

Authors:  Takaaki Fujishiro; Takafumi Hiranaka; Shingo Hashimoto; Shinya Hayashi; Masahiro Kurosaka; Taiki Kanno; Takeshi Masuda
Journal:  Int Orthop       Date:  2015-07-23       Impact factor: 3.075

2.  Analysis of acetabular orientation and femoral anteversion using images of three-dimensional reconstructed bone models.

Authors:  Jaeyeong Park; Jun-Young Kim; Hyun Deok Kim; Young Cheol Kim; Anna Seo; Minkyu Je; Jong Uk Mun; Bia Kim; Il Hyung Park; Shin-Yoon Kim
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-01-06       Impact factor: 2.924

3.  Effect of screw fixation on acetabular component alignment change in total hip arthroplasty.

Authors:  Takaaki Fujishiro; Shinya Hayashi; Noriyuki Kanzaki; Shingo Hashimoto; Nao Shibanuma; Masahiro Kurosaka
Journal:  Int Orthop       Date:  2014-01-11       Impact factor: 3.075

4.  Computed tomographic measurement of acetabular and femoral component version in total hip arthroplasty.

Authors:  Takaaki Fujishiro; Shinya Hayashi; Noriyuki Kanzaki; Shingo Hashimoto; Masahiro Kurosaka; Taiki Kanno; Takeshi Masuda
Journal:  Int Orthop       Date:  2014-01-11       Impact factor: 3.075

5.  Accuracy of combined anteversion in image-free navigated total hip arthroplasty: stem-first or cup-first technique?

Authors:  Shigeo Fukunishi; Shoji Nishio; Yuki Fujihara; Shohei Okahisa; Yu Takeda; Tomokazu Fukui; Shinichi Yoshiya
Journal:  Int Orthop       Date:  2015-05-07       Impact factor: 3.075

6.  The influence of stem alignment on the bone mineral density around the Polarstem following total hip arthroplasty.

Authors:  Masahiro Fujita; Shinya Hayashi; Shingo Hashimoto; Yuichi Kuroda; Ryosuke Kuroda; Tomoyuki Matsumoto
Journal:  Arch Orthop Trauma Surg       Date:  2022-09-20       Impact factor: 2.928

7.  The contributing factors of tapered wedge stem alignment during mini-invasive total hip arthroplasty.

Authors:  Shinya Hayashi; Takaaki Fujishiro; Shingo Hashimoto; Noriyuki Kanzaki; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  J Orthop Surg Res       Date:  2015-04-21       Impact factor: 2.359

8.  Improving MiniHip femoral prosthesis positioning using a cross-laser projection system in total hip arthroplasty by an anterolateral supine approach.

Authors:  Hideki Fujii; Tetsuo Hayama; Toshiomi Abe; Motoi Takahashi; Yohei Matsushita; Ryuichi Sato; Takuya Otani; Mitsuru Saito
Journal:  Int J Med Robot       Date:  2021-01-09       Impact factor: 2.547

9.  Comparison of Cup Setting Angle Accuracy between Computed Tomography-Based and Computed Tomography-Free Navigation in the Same Patients with Crowe's Classification I or II Hip Dysplasia.

Authors:  Nobuhiro Kaku; Hiroaki Tagomori; Hiroshi Tsumura
Journal:  Clin Orthop Surg       Date:  2021-04-12

10.  Accuracy of Component Orientation and Leg Length Adjustment in Total Hip Arthroplasty Using Image-free Navigation.

Authors:  Yu Takeda; Shigeo Fukunishi; Shoji Nishio; Yuki Fujihara; Shinichi Yoshiya
Journal:  Open Orthop J       Date:  2017-12-28
  10 in total