Literature DB >> 18835821

Accuracy and reproducibility of left ventricular outflow tract diameter measurement using transthoracic when compared with transesophageal echocardiography in systole and diastole.

Avinoam Shiran1, Salim Adawi, Majdi Ganaeem, Ehab Asmer.   

Abstract

AIMS: Accurate measurement of left ventricular outflow tract diameter (LVOTd) is essential for reliable estimation of aortic valve area (AVA) using the continuity equation. Transesophageal echocardiography (TEE) can accurately delineate the LVOT. The aim of this study was to assess the accuracy and reproducibility of LVOTd measurement using transthoracic echocardiography (TTE) with harmonic imaging when compared with TEE, in both systole and diastole. METHODS AND
RESULTS: We prospectively studied 50 patients [20 with aortic stenosis (AS) and 30 without AS]. LVOTd was measured offline in a blinded fashion in both systole and diastole by two experienced observers using TTE in the parasternal long axis view and TEE in the mid-oesophageal aortic view ( approximately 130 degrees ). There was strong correlation between TTE and TEE (r=0.91). LVOTd was slightly smaller by TTE when compared with TEE (2.11+/-0.21 vs. 2.16+/-0.22 cm, mean difference -0.05+/-0.09 cm, P=0.0003). Compared with TEE, 95% (2SD) of LVOTd measurements by TTE were within +0.14 and -0.24 cm. Inter- and intra-observer variability for LVOTd was 4.8+/-4.1 and 2.8+/-1.9% for TTE and 4.2+/-3.1 and 2.5+/-1.6% for TEE (P=0.4 and 0.6). In patients with AS, estimated AVA was 0.93+/-0.22 cm(2) using TTE and 0.96+/-0.24 cm(2) using TEE, P=0.08. Diastolic LVOTd by TEE was slightly smaller compared with systolic LVOTd by TEE (-0.03+/-0.07 cm, P=0.0005), and there was strong correlation between the two (r=0.95).
CONCLUSION: We present the data regarding accuracy and reproducibility of LVOTd measurements by TTE when compared with TEE. LVOTd measurements at end-diastole may be helpful when systolic images are suboptimal.

Entities:  

Mesh:

Year:  2008        PMID: 18835821     DOI: 10.1093/ejechocard/jen254

Source DB:  PubMed          Journal:  Eur J Echocardiogr        ISSN: 1532-2114


  10 in total

1.  Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode.

Authors:  W Wuest; K Anders; A Schuhbaeck; M S May; S Gauss; M Marwan; M Arnold; S Ensminger; G Muschiol; W G Daniel; M Uder; S Achenbach
Journal:  Eur Radiol       Date:  2011-08-17       Impact factor: 5.315

Review 2.  [Hemodynamic monitoring in intensive care and emergency medicine : Integration of clinical signs and ultrasound findings].

Authors:  D Hempel; R Pfister; G Michels
Journal:  Med Klin Intensivmed Notfmed       Date:  2016-06-09       Impact factor: 0.840

Review 3.  The role of echocardiography in transcatheter aortic valve implantation.

Authors:  Toshinari Onishi; Kaoruko Sengoku; Yasuhiro Ichibori; Isamu Mizote; Koichi Maeda; Toru Kuratani; Yoshiki Sawa; Yasushi Sakata
Journal:  Cardiovasc Diagn Ther       Date:  2018-02

4.  Novel single-source high-pitch protocol for CT angiography of the aorta: comparison to high-pitch dual-source protocol in the context of TAVI planning.

Authors:  Bernhard Bischoff; Felix G Meinel; Maximilian Reiser; Hans-Christoph Becker
Journal:  Int J Cardiovasc Imaging       Date:  2013-01-19       Impact factor: 2.357

Review 5.  The role of TTE in assessment of the patient before and following TAVI for AS.

Authors:  John Fryearson; Nicola C Edwards; Sagar N Doshi; Richard P Steeds
Journal:  Echo Res Pract       Date:  2016-04-14

6.  Minimally invasive beat-by-beat monitoring of cardiac power in normal hearts and during acute ventricular dysfunction.

Authors:  Audun E Rimehaug; Eirik Skogvoll; Petter Aadahl; Oddveig Lyng; Dag O Nordhaug; Lasse Løvstakken; Idar Kirkeby-Garstad
Journal:  Physiol Rep       Date:  2016-10

7.  Role of Transesophageal Echocardiography in the Diagnosis of Paradoxical Low Flow, Low Gradient Severe Aortic Stenosis.

Authors:  Muaz M Abudiab; Anil Pandit; Hari P Chaliki
Journal:  Korean Circ J       Date:  2016-12-27       Impact factor: 3.243

8.  Comparison of grading of aortic stenosis between transthoracic and transesophageal echocardiography in adult patients undergoing elective aortic valve replacement surgeries: A prospective observational study.

Authors:  S Nanditha; Vishwas Malik; Suruchi Hasija; Poonam Malhotra; V Sreenivas; Sandeep Chauhan
Journal:  Ann Card Anaesth       Date:  2019 Apr-Jun

9.  Comparison of flow-independent parameters for grading severity of aortic stenosis using intraoperative transesophageal echocardiography - A prospective observational study.

Authors:  S Nanditha; Vishwas Malik
Journal:  Ann Card Anaesth       Date:  2020 Oct-Dec

10.  Analysis of left ventricular function, left ventricular outflow tract and aortic valve area using computed tomography: Influence of reconstruction parameters on measurement accuracy.

Authors:  Michaela M Hell; Bettine Steinmann; Tassilo Scherkamp; Martin B Arnold; Stephan Achenbach; Mohamed Marwan
Journal:  Br J Radiol       Date:  2021-07-08       Impact factor: 3.039

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.