Literature DB >> 23324061

Mechanistic evaluation of the pros and cons of digital RT-LAMP for HIV-1 viral load quantification on a microfluidic device and improved efficiency via a two-step digital protocol.

Bing Sun1, Feng Shen, Stephanie E McCalla, Jason E Kreutz, Mikhail A Karymov, Rustem F Ismagilov.   

Abstract

Here we used a SlipChip microfluidic device to evaluate the performance of digital reverse transcription-loop-mediated isothermal amplification (dRT-LAMP) for quantification of HIV viral RNA. Tests are needed for monitoring HIV viral load to control the emergence of drug resistance and to diagnose acute HIV infections. In resource-limited settings, in vitro measurement of HIV viral load in a simple format is especially needed, and single-molecule counting using a digital format could provide a potential solution. We showed here that when one-step dRT-LAMP is used for quantification of HIV RNA, the digital count is lower than expected and is limited by the yield of desired cDNA. We were able to overcome the limitations by developing a microfluidic protocol to manipulate many single molecules in parallel through a two-step digital process. In the first step we compartmentalize the individual RNA molecules (based on Poisson statistics) and perform reverse transcription on each RNA molecule independently to produce DNA. In the second step, we perform the LAMP amplification on all individual DNA molecules in parallel. Using this new protocol, we increased the absolute efficiency (the ratio between the concentration calculated from the actual count and the expected concentration) of dRT-LAMP 10-fold, from ∼2% to ∼23%, by (i) using a more efficient reverse transcriptase, (ii) introducing RNase H to break up the DNA:RNA hybrid, and (iii) adding only the BIP primer during the RT step. We also used this two-step method to quantify HIV RNA purified from four patient samples and found that in some cases, the quantification results were highly sensitive to the sequence of the patient's HIV RNA. We learned the following three lessons from this work: (i) digital amplification technologies, including dLAMP and dPCR, may give adequate dilution curves and yet have low efficiency, thereby providing quantification values that underestimate the true concentration. Careful validation is essential before a method is considered to provide absolute quantification; (ii) the sensitivity of dLAMP to the sequence of the target nucleic acid necessitates additional validation with patient samples carrying the full spectrum of mutations; (iii) for multistep digital amplification chemistries, such as a combination of reverse transcription with amplification, microfluidic devices may be used to decouple these steps from one another and to perform them under different, individually optimized conditions for improved efficiency.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23324061      PMCID: PMC3578705          DOI: 10.1021/ac3037206

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  24 in total

1.  Loop-mediated isothermal amplification of DNA.

Authors:  T Notomi; H Okayama; H Masubuchi; T Yonekawa; K Watanabe; N Amino; T Hase
Journal:  Nucleic Acids Res       Date:  2000-06-15       Impact factor: 16.971

2.  Accelerated reaction by loop-mediated isothermal amplification using loop primers.

Authors:  K Nagamine; T Hase; T Notomi
Journal:  Mol Cell Probes       Date:  2002-06       Impact factor: 2.365

3.  Comparison of reverse transcriptases in gene expression analysis.

Authors:  Anders Ståhlberg; Mikael Kubista; Michael Pfaffl
Journal:  Clin Chem       Date:  2004-09       Impact factor: 8.327

Review 4.  Reliability of real-time reverse-transcription PCR in clinical diagnostics: gold standard or substandard?

Authors:  Jamie Murphy; Stephen A Bustin
Journal:  Expert Rev Mol Diagn       Date:  2009-03       Impact factor: 5.225

5.  Self-priming compartmentalization digital LAMP for point-of-care.

Authors:  Qiangyuan Zhu; Yibo Gao; Bingwen Yu; Hao Ren; Lin Qiu; Sihai Han; Wei Jin; Qinhan Jin; Ying Mu
Journal:  Lab Chip       Date:  2012-11-21       Impact factor: 6.799

6.  HIV viral load monitoring in resource-limited regions: optional or necessary?

Authors:  Alexandra Calmy; Nathan Ford; Bernard Hirschel; Steven J Reynolds; Lut Lynen; Eric Goemaere; Felipe Garcia de la Vega; Luc Perrin; William Rodriguez
Journal:  Clin Infect Dis       Date:  2006-11-28       Impact factor: 9.079

7.  Characterization of RNA strand displacement synthesis by Moloney murine leukemia virus reverse transcriptase.

Authors:  C D Kelleher; J J Champoux
Journal:  J Biol Chem       Date:  1998-04-17       Impact factor: 5.157

8.  Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products.

Authors:  Norihiro Tomita; Yasuyoshi Mori; Hidetoshi Kanda; Tsugunori Notomi
Journal:  Nat Protoc       Date:  2008       Impact factor: 13.491

9.  Rapid detection of HIV-1 by reverse-transcription, loop-mediated isothermal amplification (RT-LAMP).

Authors:  Kelly A Curtis; Donna L Rudolph; S Michele Owen
Journal:  J Virol Methods       Date:  2008-06-03       Impact factor: 2.014

Review 10.  HIV-1 viral load assays for resource-limited settings.

Authors:  Susan A Fiscus; Ben Cheng; Suzanne M Crowe; Lisa Demeter; Cheryl Jennings; Veronica Miller; Richard Respess; Wendy Stevens
Journal:  PLoS Med       Date:  2006-10       Impact factor: 11.069

View more
  26 in total

1.  Lack of correlation between reaction speed and analytical sensitivity in isothermal amplification reveals the value of digital methods for optimization: validation using digital real-time RT-LAMP.

Authors:  Eugenia M Khorosheva; Mikhail A Karymov; David A Selck; Rustem F Ismagilov
Journal:  Nucleic Acids Res       Date:  2015-09-10       Impact factor: 16.971

Review 2.  Slip-driven microfluidic devices for nucleic acid analysis.

Authors:  Weiyuan Lyu; Mengchao Yu; Haijun Qu; Ziqing Yu; Wenbin Du; Feng Shen
Journal:  Biomicrofluidics       Date:  2019-07-12       Impact factor: 2.800

3.  Immersed AC electrospray (iACE) for monodispersed aqueous droplet generation.

Authors:  Zehao Pan; Yongfan Men; Satyajyoti Senapati; Hsueh-Chia Chang
Journal:  Biomicrofluidics       Date:  2018-08-16       Impact factor: 2.800

4.  Emerging Loop-Mediated Isothermal Amplification-Based Microchip and Microdevice Technologies for Nucleic Acid Detection.

Authors:  Mohammadali Safavieh; Manoj K Kanakasabapathy; Farhang Tarlan; Minhaz U Ahmed; Mohammed Zourob; Waseem Asghar; Hadi Shafiee
Journal:  ACS Biomater Sci Eng       Date:  2016-01-21

5.  Self-digitization chip for quantitative detection of human papillomavirus gene using digital LAMP.

Authors:  Jason E Kreutz; Jiasi Wang; Allison M Sheen; Alison M Thompson; Jeannette P Staheli; Michael R Dyen; Qinghua Feng; Daniel T Chiu
Journal:  Lab Chip       Date:  2019-03-13       Impact factor: 6.799

Review 6.  Miniaturized devices for point of care molecular detection of HIV.

Authors:  Michael Mauk; Jinzhao Song; Haim H Bau; Robert Gross; Frederic D Bushman; Ronald G Collman; Changchun Liu
Journal:  Lab Chip       Date:  2017-01-31       Impact factor: 6.799

7.  Real-time kinetics and high-resolution melt curves in single-molecule digital LAMP to differentiate and study specific and non-specific amplification.

Authors:  Justin C Rolando; Erik Jue; Jacob T Barlow; Rustem F Ismagilov
Journal:  Nucleic Acids Res       Date:  2020-04-17       Impact factor: 16.971

8.  Digital quantification of miRNA directly in plasma using integrated comprehensive droplet digital detection.

Authors:  Kaixiang Zhang; Dong-Ku Kang; M Monsur Ali; Linan Liu; Louai Labanieh; Mengrou Lu; Hamidreza Riazifar; Thi N Nguyen; Jason A Zell; Michelle A Digman; Enrico Gratton; Jinghong Li; Weian Zhao
Journal:  Lab Chip       Date:  2015-09-21       Impact factor: 6.799

9.  Increased robustness of single-molecule counting with microfluidics, digital isothermal amplification, and a mobile phone versus real-time kinetic measurements.

Authors:  David A Selck; Mikhail A Karymov; Bing Sun; Rustem F Ismagilov
Journal:  Anal Chem       Date:  2013-11-07       Impact factor: 6.986

10.  Measuring fate and rate of single-molecule competition of amplification and restriction digestion, and its use for rapid genotyping tested with hepatitis C viral RNA.

Authors:  Bing Sun; Jesus Rodriguez-Manzano; David A Selck; Eugenia Khorosheva; Mikhail A Karymov; Rustem F Ismagilov
Journal:  Angew Chem Int Ed Engl       Date:  2014-06-02       Impact factor: 15.336

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.