Correction for collimator-detector response in SPECT using point spread function template.

Se Young Chun1, Jeffrey A Fessler, Yuni K Dewaraja.   

Abstract

Compensating for the collimator-detector response (CDR) in SPECT is important for accurate quantification. The CDR consists of both a geometric response and a septal penetration and collimator scatter response. The geometric response can be modeled analytically and is often used for modeling the whole CDR if the geometric response dominates. However, for radionuclides that emit medium or high-energy photons such as I-131, the septal penetration and collimator scatter response is significant and its modeling in the CDR correction is important for accurate quantification. There are two main methods for modeling the depth-dependent CDR so as to include both the geometric response and the septal penetration and collimator scatter response. One is to fit a Gaussian plus exponential function that is rotationally invariant to the measured point source response at several source-detector distances. However, a rotationally-invariant exponential function cannot represent the star-shaped septal penetration tails in detail. Another is to perform Monte-Carlo (MC) simulations to generate the depth-dependent point spread functions (PSFs) for all necessary distances. However, MC simulations, which require careful modeling of the SPECT detector components, can be challenging and accurate results may not be available for all of the different SPECT scanners in clinics. In this paper, we propose an alternative approach to CDR modeling. We use a Gaussian function plus a 2-D B-spline PSF template and fit the model to measurements of an I-131 point source at several distances. The proposed PSF-template-based approach is nearly non-parametric, captures the characteristics of the septal penetration tails, and minimizes the difference between the fitted and measured CDR at the distances of interest. The new model is applied to I-131 SPECT reconstructions of experimental phantom measurements, a patient study, and a MC patient simulation study employing the XCAT phantom. The proposed model yields up to a 16.5 and 10.8% higher recovery coefficient compared to the results with the conventional Gaussian model and the Gaussian plus exponential model, respectively.

Entities:  

Mesh:

Year:  2012        PMID: 23086521      PMCID: PMC3619230          DOI: 10.1109/TMI.2012.2225441

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  21 in total

1.  A 3-dimensional absorbed dose calculation method based on quantitative SPECT for radionuclide therapy: evaluation for (131)I using monte carlo simulation.

Authors:  Michael Ljungberg; Katarina Sjögreen; Xiaowei Liu; Eric Frey; Yuni Dewaraja; Sven-Erik Strand
Journal:  J Nucl Med       Date:  2002-08       Impact factor: 10.057

2.  Fast simulation of yttrium-90 bremsstrahlung photons with GATE.

Authors:  Erwann Rault; Steven Staelens; Roel Van Holen; Jan De Beenhouwer; Stefaan Vandenberghe
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

3.  The importance and implementation of accurate 3D compensation methods for quantitative SPECT.

Authors:  B M Tsui; E C Frey; X Zhao; D S Lalush; R E Johnston; W H McCartney
Journal:  Phys Med Biol       Date:  1994-03       Impact factor: 3.609

4.  Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function.

Authors:  X Song; W P Segars; Y Du; B M W Tsui; E C Frey
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

5.  Spatial resolution properties of penalized-likelihood image reconstruction: space-invariant tomographs.

Authors:  J A Fessler; W L Rogers
Journal:  IEEE Trans Image Process       Date:  1996       Impact factor: 10.856

6.  3-D Monte Carlo-Based Scatter Compensation in Quantitative I-131 SPECT Reconstruction.

Authors:  Yuni K Dewaraja; Michael Ljungberg; Jeffrey A Fessler
Journal:  IEEE Trans Nucl Sci       Date:  2006       Impact factor: 1.679

7.  Regularized reconstruction in quantitative SPECT using CT side information from hybrid imaging.

Authors:  Yuni K Dewaraja; Kenneth F Koral; Jeffrey A Fessler
Journal:  Phys Med Biol       Date:  2010-04-14       Impact factor: 3.609

8.  131I-tositumomab radioimmunotherapy: initial tumor dose-response results using 3-dimensional dosimetry including radiobiologic modeling.

Authors:  Yuni K Dewaraja; Matthew J Schipper; Peter L Roberson; Scott J Wilderman; Hanan Amro; Denise D Regan; Kenneth F Koral; Mark S Kaminski; Anca M Avram
Journal:  J Nucl Med       Date:  2010-06-16       Impact factor: 10.057

9.  Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation.

Authors:  Yuni K Dewaraja; Scott J Wilderman; Michael Ljungberg; Kenneth F Koral; Kenneth Zasadny; Mark S Kaminiski
Journal:  J Nucl Med       Date:  2005-05       Impact factor: 10.057

10.  Realistic CT simulation using the 4D XCAT phantom.

Authors:  W P Segars; M Mahesh; T J Beck; E C Frey; B M W Tsui
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

View more
  13 in total

1.  Post-reconstruction non-local means filtering methods using CT side information for quantitative SPECT.

Authors:  Se Young Chun; Jeffrey A Fessler; Yuni K Dewaraja
Journal:  Phys Med Biol       Date:  2013-09-07       Impact factor: 3.609

2.  Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging.

Authors:  Steven Tilley; Matthew Jacobson; Qian Cao; Michael Brehler; Alejandro Sisniega; Wojciech Zbijewski; J Webster Stayman
Journal:  IEEE Trans Med Imaging       Date:  2018-04       Impact factor: 10.048

3.  Image quality characteristics of myocardial perfusion SPECT imaging using state-of-the-art commercial software algorithms: evaluation of 10 reconstruction methods.

Authors:  Taher Hosny; Magdy M Khalil; Abdo A Elfiky; Wael M Elshemey
Journal:  Am J Nucl Med Mol Imaging       Date:  2020-12-15

Review 4.  Application of the 4-D XCAT Phantoms in Biomedical Imaging and Beyond.

Authors:  W Paul Segars; B M W Tsui; George S K Fung; Ehsan Samei
Journal:  IEEE Trans Med Imaging       Date:  2017-08-10       Impact factor: 10.048

Review 5.  The Use of Anatomical Information for Molecular Image Reconstruction Algorithms: Attenuation/Scatter Correction, Motion Compensation, and Noise Reduction.

Authors:  Se Young Chun
Journal:  Nucl Med Mol Imaging       Date:  2016-02-11

6.  Improved quantitative 90 Y bremsstrahlung SPECT/CT reconstruction with Monte Carlo scatter modeling.

Authors:  Yuni K Dewaraja; Se Young Chun; Ravi N Srinivasa; Ravi K Kaza; Kyle C Cuneo; Bill S Majdalany; Paula M Novelli; Michael Ljungberg; Jeffrey A Fessler
Journal:  Med Phys       Date:  2017-10-28       Impact factor: 4.071

7.  Algorithms and Analyses for Joint Spectral Image Reconstruction in Y-90 Bremsstrahlung SPECT.

Authors:  Se Young Chun; Minh Phuong Nguyen; Thanh Quoc Phan; Hanvit Kim; Jeffrey A Fessler; Yuni K Dewaraja
Journal:  IEEE Trans Med Imaging       Date:  2019-10-23       Impact factor: 10.048

8.  Alternating direction method of multiplier for tomography with nonlocal regularizers.

Authors:  Se Young Chun; Yuni K Dewaraja; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-10       Impact factor: 10.048

9.  Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise.

Authors:  Steven Tilley; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Phys Med Biol       Date:  2015-12-09       Impact factor: 3.609

Review 10.  89 Zr-ImmunoPET companion diagnostics and their impact in clinical drug development.

Authors:  Brooke N McKnight; Nerissa T Viola-Villegas
Journal:  J Labelled Comp Radiopharm       Date:  2018-03-12       Impact factor: 1.921

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.