Literature DB >> 20393233

Regularized reconstruction in quantitative SPECT using CT side information from hybrid imaging.

Yuni K Dewaraja1, Kenneth F Koral, Jeffrey A Fessler.   

Abstract

A penalized-likelihood (PL) SPECT reconstruction method using a modified regularizer that accounts for anatomical boundary side information was implemented to achieve accurate estimates of both the total target activity and the activity distribution within targets. In both simulations and experimental I-131 phantom studies, reconstructions from (1) penalized likelihood employing CT-side information-based regularization (PL-CT), (2) penalized likelihood with edge preserving regularization (no CT) and (3) penalized likelihood with conventional spatially invariant quadratic regularization (no CT) were compared with (4) ordered subset expectation maximization (OSEM), which is the iterative algorithm conventionally used in clinics for quantitative SPECT. Evaluations included phantom studies with perfect and imperfect side information and studies with uniform and non-uniform activity distributions in the target. For targets with uniform activity, the PL-CT images and profiles were closest to the 'truth', avoided the edge offshoots evident with OSEM and minimized the blurring across boundaries evident with regularization without CT information. Apart from visual comparison, reconstruction accuracy was evaluated using the bias and standard deviation (STD) of the total target activity estimate and the root mean square error (RMSE) of the activity distribution within the target. PL-CT reconstruction reduced both bias and RMSE compared with regularization without side information. When compared with unregularized OSEM, PL-CT reduced RMSE and STD while bias was comparable. For targets with non-uniform activity, these improvements with PL-CT were observed only when the change in activity was matched by a change in the anatomical image and the corresponding inner boundary was also used to control the regularization. In summary, the present work demonstrates the potential of using CT side information to obtain improved estimates of the activity distribution in targets without sacrificing the accuracy of total target activity estimation. The method is best suited for data acquired on hybrid systems where SPECT-CT misregistration is minimized. To demonstrate clinical application, the PL reconstruction with CT-based regularization was applied to data from a patient who underwent SPECT/CT imaging for tumor dosimetry following I-131 radioimmunotherapy.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20393233      PMCID: PMC2889706          DOI: 10.1088/0031-9155/55/9/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  18 in total

1.  Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels.

Authors:  Claude Comtat; Paul E Kinahan; Jeffrey A Fessler; Thomas Beyer; David W Townsend; Michel Defrise; Christian Michel
Journal:  Phys Med Biol       Date:  2002-01-07       Impact factor: 3.609

2.  Methodology to incorporate biologically effective dose and equivalent uniform dose in patient-specific 3-dimensional dosimetry for non-Hodgkin lymphoma patients targeted with 131I-tositumomab therapy.

Authors:  Hanan Amro; Scott J Wilderman; Yuni K Dewaraja; Peter L Roberson
Journal:  J Nucl Med       Date:  2010-03-17       Impact factor: 10.057

3.  Partial volume effect compensation for quantitative brain SPECT imaging.

Authors:  Yong Du; Benjamin M W Tsui; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2005-08       Impact factor: 10.048

4.  Recovery of total I-131 activity within focal volumes using SPECT and 3D OSEM.

Authors:  Kenneth F Koral; Anastasia Yendiki; Yuni K Dewaraja
Journal:  Phys Med Biol       Date:  2007-01-16       Impact factor: 3.609

5.  Spatial resolution properties of penalized-likelihood image reconstruction: space-invariant tomographs.

Authors:  J A Fessler; W L Rogers
Journal:  IEEE Trans Image Process       Date:  1996       Impact factor: 10.856

6.  Penalized weighted least-squares image reconstruction for positron emission tomography.

Authors:  J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

7.  Accuracy of quantitative reconstructions in SPECT/CT imaging.

Authors:  S Shcherbinin; A Celler; T Belhocine; R Vanderwerf; A Driedger
Journal:  Phys Med Biol       Date:  2008-08-04       Impact factor: 3.609

8.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

9.  Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation.

Authors:  Yuni K Dewaraja; Scott J Wilderman; Michael Ljungberg; Kenneth F Koral; Kenneth Zasadny; Mark S Kaminiski
Journal:  J Nucl Med       Date:  2005-05       Impact factor: 10.057

10.  Three-dimensional radiobiologic dosimetry: application of radiobiologic modeling to patient-specific 3-dimensional imaging-based internal dosimetry.

Authors:  Andrew R Prideaux; Hong Song; Robert F Hobbs; Bin He; Eric C Frey; Paul W Ladenson; Richard L Wahl; George Sgouros
Journal:  J Nucl Med       Date:  2007-05-15       Impact factor: 10.057

View more
  13 in total

1.  Post-reconstruction non-local means filtering methods using CT side information for quantitative SPECT.

Authors:  Se Young Chun; Jeffrey A Fessler; Yuni K Dewaraja
Journal:  Phys Med Biol       Date:  2013-09-07       Impact factor: 3.609

2.  PET image reconstruction with anatomical edge guided level set prior.

Authors:  Jinxiu Cheng-Liao; Jinyi Qi
Journal:  Phys Med Biol       Date:  2011-10-07       Impact factor: 3.609

3.  MIRD pamphlet No. 23: quantitative SPECT for patient-specific 3-dimensional dosimetry in internal radionuclide therapy.

Authors:  Yuni K Dewaraja; Eric C Frey; George Sgouros; A Bertrand Brill; Peter Roberson; Pat B Zanzonico; Michael Ljungberg
Journal:  J Nucl Med       Date:  2012-06-28       Impact factor: 10.057

Review 4.  The Use of Anatomical Information for Molecular Image Reconstruction Algorithms: Attenuation/Scatter Correction, Motion Compensation, and Noise Reduction.

Authors:  Se Young Chun
Journal:  Nucl Med Mol Imaging       Date:  2016-02-11

5.  Algorithms and Analyses for Joint Spectral Image Reconstruction in Y-90 Bremsstrahlung SPECT.

Authors:  Se Young Chun; Minh Phuong Nguyen; Thanh Quoc Phan; Hanvit Kim; Jeffrey A Fessler; Yuni K Dewaraja
Journal:  IEEE Trans Med Imaging       Date:  2019-10-23       Impact factor: 10.048

6.  Development and evaluation of convergent and accelerated penalized SPECT image reconstruction methods for improved dose-volume histogram estimation in radiopharmaceutical therapy.

Authors:  Lishui Cheng; Robert F Hobbs; George Sgouros; Eric C Frey
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

7.  Sparsity promoting regularization for effective noise suppression in SPECT image reconstruction.

Authors:  Wei Zheng; Si Li; Andrzej Krol; C Ross Schmidtlein; Xueying Zeng; Yuesheng Xu
Journal:  Inverse Probl       Date:  2019-10-04       Impact factor: 2.407

8.  Anatomically-aided PET reconstruction using the kernel method.

Authors:  Will Hutchcroft; Guobao Wang; Kevin T Chen; Ciprian Catana; Jinyi Qi
Journal:  Phys Med Biol       Date:  2016-08-19       Impact factor: 3.609

9.  Direct Patlak Reconstruction From Dynamic PET Data Using the Kernel Method With MRI Information Based on Structural Similarity.

Authors:  Kuang Gong; Jinxiu Cheng-Liao; Guobao Wang; Kevin T Chen; Ciprian Catana; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2018-04       Impact factor: 10.048

10.  Correction for collimator-detector response in SPECT using point spread function template.

Authors:  Se Young Chun; Jeffrey A Fessler; Yuni K Dewaraja
Journal:  IEEE Trans Med Imaging       Date:  2012-10-18       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.