Literature DB >> 23956327

Post-reconstruction non-local means filtering methods using CT side information for quantitative SPECT.

Se Young Chun1, Jeffrey A Fessler, Yuni K Dewaraja.   

Abstract

Quantitative SPECT techniques are important for many applications including internal emitter therapy dosimetry where accurate estimation of total target activity and activity distribution within targets are both potentially important for dose–response evaluations. We investigated non-local means (NLM) post-reconstruction filtering for accurate I-131 SPECT estimation of both total target activity and the 3D activity distribution. We first investigated activity estimation versus number of ordered-subsets expectation–maximization (OSEM) iterations. We performed simulations using the XCAT phantom with tumors containing a uniform and a non-uniform activity distribution, and measured the recovery coefficient (RC) and the root mean squared error (RMSE) to quantify total target activity and activity distribution, respectively. We observed that using more OSEM iterations is essential for accurate estimation of RC, but may or may not improve RMSE. We then investigated various post-reconstruction filtering methods to suppress noise at high iteration while preserving image details so that both RC and RMSE can be improved. Recently, NLM filtering methods have shown promising results for noise reduction. Moreover, NLM methods using high-quality side information can improve image quality further. We investigated several NLM methods with and without CT side information for I-131 SPECT imaging and compared them to conventional Gaussian filtering and to unfiltered methods. We studied four different ways of incorporating CT information in the NLM methods: two known (NLM CT-B and NLM CT-M) and two newly considered (NLM CT-S and NLM CT-H). We also evaluated the robustness of NLM filtering using CT information to erroneous CT. NLM CT-S and NLM CT-H yielded comparable RC values to unfiltered images while substantially reducing RMSE. NLM CT-S achieved −2.7 to 2.6% increase of RC compared to no filtering and NLM CT-H yielded up to 6% decrease in RC while other methods yielded lower RCs than them: Gaussian filtering (up to 11.8% decrease in RC), NLM method without CT (up to 9.5% decrease in RC), and NLM CT-M and NLM CT-B (up to 19.4% decrease in RC). NLM CT-S and NLM CT-H achieved 8.2 to 33.9% and −0.9 to 36% decreased RMSE on tumors compared to no filtering respectively while other methods yielded less reduced or increased RMSE: Gaussian filtering (up to 7.9% increase in RMSE), NLM method without CT (up to 18.3% increase in RMSE), and NLM CT-M and NLM CT-B (up to 31.5% increase in RMSE). NLM CT-S and NLM CT-H also yielded images with tumor shapes that better-matched the true shapes than other methods. All NLM methods using CT information were robust to small misregistration between SPECT and CT, but NLM CT-S and NLM CT-H were more sensitive than NLM CT-M and NLM CT-B to missing CT information.

Entities:  

Mesh:

Year:  2013        PMID: 23956327      PMCID: PMC3821737          DOI: 10.1088/0031-9155/58/17/6225

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  Evaluation of three MRI-based anatomical priors for quantitative PET brain imaging.

Authors:  Kathleen Vunckx; Ameya Atre; Kristof Baete; Anthonin Reilhac; Christophe M Deroose; Koen Van Laere; Johan Nuyts
Journal:  IEEE Trans Med Imaging       Date:  2011-10-27       Impact factor: 10.048

2.  3-D Monte Carlo-Based Scatter Compensation in Quantitative I-131 SPECT Reconstruction.

Authors:  Yuni K Dewaraja; Michael Ljungberg; Jeffrey A Fessler
Journal:  IEEE Trans Nucl Sci       Date:  2006       Impact factor: 1.679

3.  Regularized reconstruction in quantitative SPECT using CT side information from hybrid imaging.

Authors:  Yuni K Dewaraja; Kenneth F Koral; Jeffrey A Fessler
Journal:  Phys Med Biol       Date:  2010-04-14       Impact factor: 3.609

4.  Penalized likelihood PET image reconstruction using patch-based edge-preserving regularization.

Authors:  Guobao Wang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2012-08-02       Impact factor: 10.048

5.  131I-tositumomab radioimmunotherapy: initial tumor dose-response results using 3-dimensional dosimetry including radiobiologic modeling.

Authors:  Yuni K Dewaraja; Matthew J Schipper; Peter L Roberson; Scott J Wilderman; Hanan Amro; Denise D Regan; Kenneth F Koral; Mark S Kaminski; Anca M Avram
Journal:  J Nucl Med       Date:  2010-06-16       Impact factor: 10.057

6.  Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation.

Authors:  Yuni K Dewaraja; Scott J Wilderman; Michael Ljungberg; Kenneth F Koral; Kenneth Zasadny; Mark S Kaminiski
Journal:  J Nucl Med       Date:  2005-05       Impact factor: 10.057

7.  Patient-specific, 3-dimensional dosimetry in non-Hodgkin's lymphoma patients treated with 131I-anti-B1 antibody: assessment of tumor dose-response.

Authors:  George Sgouros; Shannon Squeri; Ase M Ballangrud; Katherine S Kolbert; Jerrold B Teitcher; Katherine S Panageas; Ronald D Finn; Chaitanya R Divgi; Steven M Larson; Andrew D Zelenetz
Journal:  J Nucl Med       Date:  2003-02       Impact factor: 10.057

8.  Quantification of dose nonuniformities by voxel-based dosimetry in patients receiving 90Y-ibritumomab-tiuxetan.

Authors:  Francesco Cicone; Marco D'Arienzo; Andrea Carpaneto; Eleonora Russo; Angela Coniglio; Angelika Bischof Delaloye; Francesco Scopinaro
Journal:  Cancer Biother Radiopharm       Date:  2013-01-04       Impact factor: 3.099

9.  Realistic CT simulation using the 4D XCAT phantom.

Authors:  W P Segars; M Mahesh; T J Beck; E C Frey; B M W Tsui
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

10.  Correction for collimator-detector response in SPECT using point spread function template.

Authors:  Se Young Chun; Jeffrey A Fessler; Yuni K Dewaraja
Journal:  IEEE Trans Med Imaging       Date:  2012-10-18       Impact factor: 10.048

View more
  7 in total

Review 1.  Local and Non-local Regularization Techniques in Emission (PET/SPECT) Tomographic Image Reconstruction Methods.

Authors:  Munir Ahmad; Tasawar Shahzad; Khalid Masood; Khalid Rashid; Muhammad Tanveer; Rabail Iqbal; Nasir Hussain; Abubakar Shahid
Journal:  J Digit Imaging       Date:  2016-06       Impact factor: 4.056

Review 2.  The Use of Anatomical Information for Molecular Image Reconstruction Algorithms: Attenuation/Scatter Correction, Motion Compensation, and Noise Reduction.

Authors:  Se Young Chun
Journal:  Nucl Med Mol Imaging       Date:  2016-02-11

3.  Quantitative SPECT/CT Imaging of (177)Lu with In Vivo Validation in Patients Undergoing Peptide Receptor Radionuclide Therapy.

Authors:  J C Sanders; T Kuwert; J Hornegger; P Ritt
Journal:  Mol Imaging Biol       Date:  2015-08       Impact factor: 3.488

Review 4.  Applications of nonlocal means algorithm in low-dose X-ray CT image processing and reconstruction: A review.

Authors:  Hao Zhang; Dong Zeng; Hua Zhang; Jing Wang; Zhengrong Liang; Jianhua Ma
Journal:  Med Phys       Date:  2017-03       Impact factor: 4.071

5.  Multi-Level Canonical Correlation Analysis for Standard-Dose PET Image Estimation.

Authors:  Ehsan Adeli; David S Lalush
Journal:  IEEE Trans Image Process       Date:  2016-05-11       Impact factor: 10.856

6.  Direct Patlak Reconstruction From Dynamic PET Data Using the Kernel Method With MRI Information Based on Structural Similarity.

Authors:  Kuang Gong; Jinxiu Cheng-Liao; Guobao Wang; Kevin T Chen; Ciprian Catana; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2018-04       Impact factor: 10.048

7.  Non-local means denoising of dynamic PET images.

Authors:  Joyita Dutta; Richard M Leahy; Quanzheng Li
Journal:  PLoS One       Date:  2013-12-05       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.