Literature DB >> 20104252

3-D Monte Carlo-Based Scatter Compensation in Quantitative I-131 SPECT Reconstruction.

Yuni K Dewaraja1, Michael Ljungberg, Jeffrey A Fessler.   

Abstract

We have implemented highly accurate Monte Carlo based scatter modeling (MCS) with 3-D ordered subsets expectation maximization (OSEM) reconstruction for I-131 single photon emission computed tomography (SPECT). The scatter is included in the statistical model as an additive term and attenuation and detector response are included in the forward/backprojector. In the present implementation of MCS, a simple multiple window-based estimate is used for the initial iterations and in the later iterations the Monte Carlo estimate is used for several iterations before it is updated. For I-131, MCS was evaluated and compared with triple energy window (TEW) scatter compensation using simulation studies of a mathematical phantom and a clinically realistic voxel-phantom. Even after just two Monte Carlo updates, excellent agreement was found between the MCS estimate and the true scatter distribution. Accuracy and noise of the reconstructed images were superior with MCS compared to TEW. However, the improvement was not large, and in some cases may not justify the large computational requirements of MCS. Furthermore, it was shown that the TEW correction could be improved for most of the targets investigated here by applying a suitably chosen scaling factor to the scatter estimate. Finally clinical application of MCS was demonstrated by applying the method to an I-131 radioimmunotherapy (RIT) patient study.

Entities:  

Year:  2006        PMID: 20104252      PMCID: PMC2810869          DOI: 10.1109/TNS.2005.862956

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  14 in total

1.  Characterization of scatter and penetration using Monte Carlo simulation in 131I imaging.

Authors:  Y K Dewaraja; M Ljungberg; K F Koral
Journal:  J Nucl Med       Date:  2000-01       Impact factor: 10.057

2.  Initial results for Hybrid SPECT--conjugate-view tumor dosimetry in 131I-anti-B1 antibody therapy of previously untreated patients with lymphoma.

Authors:  K F Koral; Y Dewaraja; J Li; C L Barrett; D D Regan; K R Zasadny; S G Rommelfanger; I R Francis; M S Kaminski; R L Wahl
Journal:  J Nucl Med       Date:  2000-09       Impact factor: 10.057

3.  Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation.

Authors:  Freek J Beekman; Hugo W A M de Jong; Sander van Geloven
Journal:  IEEE Trans Med Imaging       Date:  2002-08       Impact factor: 10.048

Review 4.  Scatter modelling and compensation in emission tomography.

Authors:  Habib Zaidi; Kenneth F Koral
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-31       Impact factor: 9.236

5.  Development and validation of a Monte Carlo simulation of photon transport in an Anger camera.

Authors:  D J De Vries; S C Moore; R E Zimmerman; S P Mueller; B Friedland; R C Lanza
Journal:  IEEE Trans Med Imaging       Date:  1990       Impact factor: 10.048

6.  A practical method for position-dependent Compton-scatter correction in single photon emission CT.

Authors:  K Ogawa; Y Harata; T Ichihara; A Kubo; S Hashimoto
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

7.  A Monte Carlo program for the simulation of scintillation camera characteristics.

Authors:  M Ljungberg; S E Strand
Journal:  Comput Methods Programs Biomed       Date:  1989-08       Impact factor: 5.428

8.  Computerized three-dimensional segmented human anatomy.

Authors:  I G Zubal; C R Harrell; E O Smith; Z Rattner; G Gindi; P B Hoffer
Journal:  Med Phys       Date:  1994-02       Impact factor: 4.071

9.  Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation.

Authors:  Yuni K Dewaraja; Scott J Wilderman; Michael Ljungberg; Kenneth F Koral; Kenneth Zasadny; Mark S Kaminiski
Journal:  J Nucl Med       Date:  2005-05       Impact factor: 10.057

10.  Accuracy of 131I tumor quantification in radioimmunotherapy using SPECT imaging with an ultra-high-energy collimator: Monte Carlo study.

Authors:  Y K Dewaraja; M Ljungberg; K F Koral
Journal:  J Nucl Med       Date:  2000-10       Impact factor: 10.057

View more
  18 in total

1.  Rapid Optimization of SPECT Scatter Correction Using Model LROC Observers.

Authors:  Santosh Kulkarni; Parmeshwar Khurd; Lili Zhou; Gene Gindi
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2007

2.  Post-reconstruction non-local means filtering methods using CT side information for quantitative SPECT.

Authors:  Se Young Chun; Jeffrey A Fessler; Yuni K Dewaraja
Journal:  Phys Med Biol       Date:  2013-09-07       Impact factor: 3.609

3.  EQPlanar: a maximum-likelihood method for accurate organ activity estimation from whole body planar projections.

Authors:  N Song; B He; R L Wahl; E C Frey
Journal:  Phys Med Biol       Date:  2011-08-03       Impact factor: 3.609

4.  A residual correction method for high-resolution PET reconstruction with application to on-the-fly Monte Carlo based model of positron range.

Authors:  Lin Fu; Jinyi Qi
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

5.  Development and evaluation of a model-based downscatter compensation method for quantitative I-131 SPECT.

Authors:  Na Song; Yong Du; Bin He; Eric C Frey
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

6.  MIRD pamphlet No. 23: quantitative SPECT for patient-specific 3-dimensional dosimetry in internal radionuclide therapy.

Authors:  Yuni K Dewaraja; Eric C Frey; George Sgouros; A Bertrand Brill; Peter Roberson; Pat B Zanzonico; Michael Ljungberg
Journal:  J Nucl Med       Date:  2012-06-28       Impact factor: 10.057

Review 7.  The Use of Anatomical Information for Molecular Image Reconstruction Algorithms: Attenuation/Scatter Correction, Motion Compensation, and Noise Reduction.

Authors:  Se Young Chun
Journal:  Nucl Med Mol Imaging       Date:  2016-02-11

8.  Improved quantitative 90 Y bremsstrahlung SPECT/CT reconstruction with Monte Carlo scatter modeling.

Authors:  Yuni K Dewaraja; Se Young Chun; Ravi N Srinivasa; Ravi K Kaza; Kyle C Cuneo; Bill S Majdalany; Paula M Novelli; Michael Ljungberg; Jeffrey A Fessler
Journal:  Med Phys       Date:  2017-10-28       Impact factor: 4.071

9.  Improved activity estimation with MC-JOSEM versus TEW-JOSEM in 111In SPECT.

Authors:  Jinsong Ouyang; Georges El Fakhri; Stephen C Moore
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

10.  Use of integrated SPECT/CT imaging for tumor dosimetry in I-131 radioimmunotherapy: a pilot patient study.

Authors:  Yuni K Dewaraja; Scott J Wilderman; Kenneth F Koral; Mark S Kaminski; Anca M Avram
Journal:  Cancer Biother Radiopharm       Date:  2009-08       Impact factor: 3.099

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.