Literature DB >> 23041985

Adiabatic RF pulse design for Bloch-Siegert B1+ mapping.

Mohammad Mehdi Khalighi1, Brian K Rutt, Adam B Kerr.   

Abstract

The Bloch-Siegert (B-S) B1+ mapping method has been shown to be fast and accurate, yet it suffers from high Specific Absorption Rate (SAR) and moderately long echo time. An adiabatic RF pulse design is introduced here for optimizing the off-resonant B-S RF pulse to achieve more B-S B1+ measurement sensitivity for a given pulse width. The extra sensitivity can be used for higher angle-to-noise ratio B1+ maps or traded off for faster scans. Using numerical simulations and phantom experiments, it is shown that a numerically optimized 2-ms adiabatic B-S pulse is 2.5 times more efficient than a conventional 6-ms Fermi-shaped B-S pulse. The adiabatic B-S pulse performance is validated in a phantom, and in vivo brain B1+ mapping at 3T and 7T are shown.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  Bloch‐Siegert shift; adiabatic RF pulse design; flip angle; off resonance; parallel transmit

Mesh:

Year:  2012        PMID: 23041985      PMCID: PMC3796009          DOI: 10.1002/mrm.24507

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  The return of the frequency sweep: designing adiabatic pulses for contemporary NMR.

Authors:  M Garwood; L DelaBarre
Journal:  J Magn Reson       Date:  2001-12       Impact factor: 2.229

2.  RF pulse optimization for Bloch-Siegert B ₁⁺ mapping.

Authors:  Mohammad Mehdi Khalighi; Brian K Rutt; Adam B Kerr
Journal:  Magn Reson Med       Date:  2011-12-05       Impact factor: 4.668

3.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

4.  Parallel excitation with an array of transmit coils.

Authors:  Yudong Zhu
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

5.  DREAM--a novel approach for robust, ultrafast, multislice B₁ mapping.

Authors:  Kay Nehrke; Peter Börnert
Journal:  Magn Reson Med       Date:  2012-01-17       Impact factor: 4.668

6.  B1 mapping by Bloch-Siegert shift.

Authors:  Laura I Sacolick; Florian Wiesinger; Ileana Hancu; Mika W Vogel
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

7.  Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field.

Authors:  Vasily L Yarnykh
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

8.  A phase-sensitive method of flip angle mapping.

Authors:  Glen R Morrell
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

9.  Imaging of the active B1 field in vivo.

Authors:  R Stollberger; P Wach
Journal:  Magn Reson Med       Date:  1996-02       Impact factor: 4.668

10.  Gleaning multicomponent T1 and T2 information from steady-state imaging data.

Authors:  Sean C L Deoni; Brian K Rutt; Tarunya Arun; Carlo Pierpaoli; Derek K Jones
Journal:  Magn Reson Med       Date:  2008-12       Impact factor: 4.668

View more
  8 in total

1.  Semi-adiabatic Shinnar-Le Roux pulses and their application to diffusion tensor imaging of humans at 7T.

Authors:  Priti Balchandani; Deqiang Qiu
Journal:  Magn Reson Imaging       Date:  2014-04-13       Impact factor: 2.546

2.  Motion-robust cardiac B1+ mapping at 3T using interleaved bloch-siegert shifts.

Authors:  Sebastian Weingärtner; Fabian Zimmer; Gregory J Metzger; Kâmil Uğurbil; Pierre-Francois Van de Moortele; Mehmet Akçakaya
Journal:  Magn Reson Med       Date:  2016-09-07       Impact factor: 4.668

Review 3.  Ultra-High-Field MR Neuroimaging.

Authors:  P Balchandani; T P Naidich
Journal:  AJNR Am J Neuroradiol       Date:  2014-12-18       Impact factor: 3.825

4.  Selective excitation localized by the Bloch-Siegert shift and a B 1 + gradient.

Authors:  Jonathan B Martin; Sai Abitha Srinivas; Christopher E Vaughn; Heng Sun; Mark A Griswold; William A Grissom
Journal:  Magn Reson Med       Date:  2022-04-25       Impact factor: 3.737

5.  Improved slice-selective adiabatic excitation.

Authors:  Priti Balchandani; Gary Glover; John Pauly; Daniel Spielman
Journal:  Magn Reson Med       Date:  2013-02-11       Impact factor: 4.668

6.  Practical methods for improving B1+ homogeneity in 3 Tesla breast imaging.

Authors:  Simone A Winkler; Brian K Rutt
Journal:  J Magn Reson Imaging       Date:  2014-04-10       Impact factor: 4.813

7.  Prospective motion correction using inductively coupled wireless RF coils.

Authors:  Melvyn B Ooi; Murat Aksoy; Julian Maclaren; Ronald D Watkins; Roland Bammer
Journal:  Magn Reson Med       Date:  2013-06-27       Impact factor: 4.668

8.  Robust 3D Bloch-Siegert based B 1 + mapping using multi-echo general linear modeling.

Authors:  Nadège Corbin; Julio Acosta-Cabronero; Shaihan J Malik; Martina F Callaghan
Journal:  Magn Reson Med       Date:  2019-07-18       Impact factor: 4.668

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.