Literature DB >> 22252850

DREAM--a novel approach for robust, ultrafast, multislice B₁ mapping.

Kay Nehrke1, Peter Börnert.   

Abstract

A novel multislice B₁-mapping method dubbed dual refocusing echo acquisition mode is proposed, able to cover the whole transmit coil volume in only one second, which is more than an order of magnitude faster than established approaches. The dual refocusing echo acquisition mode technique employs a stimulated echo acquisition mode (STEAM) preparation sequence followed by a tailored single-shot gradient echo sequence, measuring simultaneously the stimulated echo and the free induction decay as gradient-recalled echoes, and determining the actual flip angle of the STEAM preparation radiofrequency pulses from the ratio of the two measured signals. Due to an elaborated timing scheme, the method is insensitive against susceptibility/chemical shift effects and can deliver a B₀ phase map and a transceive phase map for free. The approach has only a weak T₁ and T₂ dependence and moreover, causes only a low specific absorption rate (SAR) burden. The accuracy of the method with respect to systematic and statistical errors is investigated both, theoretically and in experiments on phantoms. In addition, the performance of the approach is demonstrated in vivo in B₁-mapping and radiofrequency shimming experiments on the abdomen, the legs, and the head on an eight-channel parallel transmit 3 T MRI system.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22252850     DOI: 10.1002/mrm.24158

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  90 in total

1.  Measuring B1 distributions by B1 phase encoding.

Authors:  Kalina V Jordanova; Dwight G Nishimura; Adam B Kerr
Journal:  Magn Reson Med       Date:  2016-01-17       Impact factor: 4.668

2.  Motion correction of multi-contrast images applied to T₁and T₂quantification in cardiac MRI.

Authors:  Anne Menini; Glenn S Slavin; Jeffrey A Stainsby; Pauline Ferry; Jacques Felblinger; Freddy Odille
Journal:  MAGMA       Date:  2015-02       Impact factor: 2.310

3.  7 Tesla quantitative hip MRI: T1, T2 and T2* mapping of hip cartilage in healthy volunteers.

Authors:  Andrea Lazik; Jens M Theysohn; Christina Geis; Sören Johst; Mark E Ladd; Harald H Quick; Oliver Kraff
Journal:  Eur Radiol       Date:  2015-08-28       Impact factor: 5.315

4.  Lowering the B1 threshold for improved BEAR B1 mapping.

Authors:  Kalina V Jordanova; Dwight G Nishimura; Adam B Kerr
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

5.  Quantitative prediction of radio frequency induced local heating derived from measured magnetic field maps in magnetic resonance imaging: A phantom validation at 7 T.

Authors:  Xiaotong Zhang; Pierre-Francois Van de Moortele; Jiaen Liu; Sebastian Schmitter; Bin He
Journal:  Appl Phys Lett       Date:  2014-12-15       Impact factor: 3.791

6.  Improved traveling-wave efficiency in 7T human MRI using passive local loop and dipole arrays.

Authors:  Xinqiang Yan; Xiaoliang Zhang; John C Gore; William A Grissom
Journal:  Magn Reson Imaging       Date:  2017-02-09       Impact factor: 2.546

7.  Radiofrequency transmit calibration: A multi-center evaluation of vendor-provided radiofrequency transmit mapping methods.

Authors:  Yannick Bliesener; Xinran Zhong; Yi Guo; Michael Boss; Ryan Bosca; Hendrik Laue; Caroline Chung; Kyunghyun Sung; Krishna S Nayak
Journal:  Med Phys       Date:  2019-04-15       Impact factor: 4.071

8.  Mapping electrical properties heterogeneity of tumor using boundary informed electrical properties tomography (BIEPT) at 7T.

Authors:  Yicun Wang; Qi Shao; Pierre-Francois Van de Moortele; Emilian Racila; Jiaen Liu; John Bischof; Bin He
Journal:  Magn Reson Med       Date:  2018-09-19       Impact factor: 4.668

Review 9.  Magnetic-resonance-based electrical properties tomography: a review.

Authors:  Xiaotong Zhang; Jiaen Liu; Bin He
Journal:  IEEE Rev Biomed Eng       Date:  2014

10.  Joint design of large-tip-angle parallel RF pulses and blipped gradient trajectories.

Authors:  Zhipeng Cao; Manus J Donahue; Jun Ma; William A Grissom
Journal:  Magn Reson Med       Date:  2015-04-27       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.