Renal perfusion and hemodynamics: accurate in vivo determination at CT with a 10-fold decrease in radiation dose and HYPR noise reduction.

Xin Liu1, Andrew N Primak, James D Krier, Lifeng Yu, Lilach O Lerman, Cynthia H McCollough.   

Abstract

PURPOSE: To prospectively evaluate the accuracy of computed tomographic (CT) perfusion measurements of renal hemodynamics and function obtained by using images acquired with one-tenth the typical radiation dose and postprocessed with a highly constrained back-projection (HYPR)-local reconstruction (LR) noise-reduction technique.
MATERIALS AND METHODS: This study was approved by the institutional Animal Care and Use Committee. Two consecutive CT perfusion acquisitions were performed in 10 anesthetized pigs over 180 seconds by using routine (80 kV, 160 mAs) and one-tenth (80 kV, 16 mAs) dose levels. Images obtained with each acquisition were reconstructed with identical parameters, and the one-tenth dose images were also processed with a HYPR-LR algorithm. Attenuation changes in kidneys were determined as a function of time to form time-attenuation curves (TACs). Extended gamma-variate curve-fitting was performed, and regional perfusion, glomerular filtration rate, and renal blood flow were calculated. Image quality was evaluated (in 10 pigs), and the agreement for renal perfusion and function between the routine dose and the one-tenth dose HYPR-LR images was determined (for 20 kidneys) by using statistical methods. Statistical analysis was performed by using the paired t test, linear regression, and Bland-Altman analysis.
RESULTS: TACs obtained with the one-tenth dose were similar to those obtained with the routine dose. Statistical analysis showed that there were no significant differences between the routine dose and the one-tenth dose acquisitions in renal perfusion and hemodynamic values and that there were slight but statistically significant differences in some values with the one-tenth dose HYPR-LR-processed acquisition. The image quality of the one-tenth dose acquisition was improved by using the HYPR-LR algorithm. Linear regression and Bland-Altman plots showed agreement between the images acquired by using the routine dose and those acquired by using the one-tenth dose with HYPR-LR processing.
CONCLUSION: A 10-fold dose reduction at renal perfusion CT imaging can be achieved in vivo, without loss of accuracy. The image quality of the one-tenth dose images could be improved to be near that of the routine dose images by using the HYPR-LR noise-reduction algorithm. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2531081677/-/DC1.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19789255      PMCID: PMC2755800          DOI: 10.1148/radiol.2531081677

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  20 in total

1.  Quantitation of the in vivo kidney volume with cine computed tomography.

Authors:  L O Lerman; M D Bentley; M R Bell; J A Rumberger; J C Romero
Journal:  Invest Radiol       Date:  1990-11       Impact factor: 6.016

2.  Colour perfusion imaging: a new application of computed tomography.

Authors:  K A Miles; M Hayball; A K Dixon
Journal:  Lancet       Date:  1991-03-16       Impact factor: 79.321

3.  Improved waveform fidelity using local HYPR reconstruction (HYPR LR).

Authors:  Kevin M Johnson; Julia Velikina; Yijing Wu; Steve Kecskemeti; Oliver Wieben; Charles A Mistretta
Journal:  Magn Reson Med       Date:  2008-03       Impact factor: 4.668

4.  Renal tubular dynamics in the intact canine kidney.

Authors:  L O Lerman; M Rodriguez-Porcel; P F Sheedy; J C Romero
Journal:  Kidney Int       Date:  1996-10       Impact factor: 10.612

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Noninvasive measurement of concurrent single-kidney perfusion, glomerular filtration, and tubular function.

Authors:  J D Krier; E L Ritman; Z Bajzer; J C Romero; A Lerman; L O Lerman
Journal:  Am J Physiol Renal Physiol       Date:  2001-10

7.  Quantification of global and regional renal blood flow with electron beam computed tomography.

Authors:  L O Lerman; M R Bell; V Lahera; J A Rumberger; P F Sheedy; A Sanchez Fueyo; J C Romero
Journal:  Am J Hypertens       Date:  1994-09       Impact factor: 2.689

Review 8.  Potential biological effects following high X-ray dose interventional procedures.

Authors:  L K Wagner; P J Eifel; R A Geise
Journal:  J Vasc Interv Radiol       Date:  1994 Jan-Feb       Impact factor: 3.464

9.  Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data.

Authors:  C S Patlak; R G Blasberg; J D Fenstermacher
Journal:  J Cereb Blood Flow Metab       Date:  1983-03       Impact factor: 6.200

10.  Reproducibility of human kidney perfusion and volume determinations with electron beam computed tomography.

Authors:  L O Lerman; A L Flickinger; P F Sheedy; S T Turner
Journal:  Invest Radiol       Date:  1996-04       Impact factor: 6.016

View more
  14 in total

1.  A strategy to decrease partial scan reconstruction artifacts in myocardial perfusion CT: phantom and in vivo evaluation.

Authors:  Juan C Ramirez-Giraldo; Lifeng Yu; Birgit Kantor; Erik L Ritman; Cynthia H McCollough
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

3.  Nonconvex prior image constrained compressed sensing (NCPICCS): theory and simulations on perfusion CT.

Authors:  J C Ramirez-Giraldo; J Trzasko; S Leng; L Yu; A Manduca; C H McCollough
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

Review 4.  Newer CT applications and their alternatives: what is appropriate in children?

Authors:  R Paul Guillerman
Journal:  Pediatr Radiol       Date:  2011-08-17

5.  Reduction of image noise in low tube current dynamic CT myocardial perfusion imaging using HYPR processing: a time-attenuation curve analysis.

Authors:  Michael A Speidel; Courtney L Bateman; Yinghua Tao; Amish N Raval; Timothy A Hacker; Scott B Reeder; Michael S Van Lysel
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

6.  Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

7.  Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging.

Authors:  Pascal Theriault Lauzier; Jie Tang; Michael A Speidel; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

8.  Porcine ex vivo liver phantom for dynamic contrast-enhanced computed tomography: development and initial results.

Authors:  Scott M Thompson; Juan C Ramirez-Giraldo; Bruce Knudsen; Joseph P Grande; Jodie A Christner; Man Xu; David A Woodrum; Cynthia H McCollough; Matthew R Callstrom
Journal:  Invest Radiol       Date:  2011-09       Impact factor: 6.016

9.  Renal Adiposity Does not Preclude Quantitative Assessment of Renal Function Using Dual-Energy Multidetector CT in Mildly Obese Human Subjects.

Authors:  Christopher M Ferguson; Alfonso Eirin; Gregory J Michalak; Ahmad F Hedayat; Abdelrhman M Abumoawad; Ahmed Saad; Xiangyang Zhu; Stephen C Textor; Cynthia H McCollough; Lilach O Lerman
Journal:  Acad Radiol       Date:  2019-01-14       Impact factor: 3.173

10.  Reliable Assessment of Swine Renal Fibrosis Using Quantitative Magnetization Transfer Imaging.

Authors:  Kai Jiang; Christopher M Ferguson; Roger C Grimm; Xiangyang Zhu; James F Glockner; Lilach O Lerman
Journal:  Invest Radiol       Date:  2022-05-01       Impact factor: 6.016

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.