Literature DB >> 25026866

Accuracy of lung nodule volumetry in low-dose CT with iterative reconstruction: an anthropomorphic thoracic phantom study.

K W Doo1, E-Y Kang, H S Yong, O H Woo, K Y Lee, Y-W Oh.   

Abstract

OBJECTIVE: The purpose of this study was to assess accuracy of lung nodule volumetry in low-dose CT with application of iterative reconstruction (IR) according to nodule size, nodule density and CT tube currents, using artificial lung nodules within an anthropomorphic thoracic phantom.
METHODS: Eight artificial nodules (four diameters: 5, 8, 10 and 12 mm; two CT densities: -630 HU that represents ground-glass nodule and +100 HU that represents solid nodule) were randomly placed inside a thoracic phantom. Scans were performed with tube current-time product to 10, 20, 30 and 50 mAs. Images were reconstructed with IR and filtered back projection (FBP). We compared volume estimates to a reference standard and calculated the absolute percentage error (APE).
RESULTS: The APE of all nodules was significantly lower when IR was used than with FBP (7.5 ± 4.7% compared with 9.0 ±6.9%; p < 0.001). The effect of IR was more pronounced for smaller nodules (p < 0.001). IR showed a significantly lower APE than FBP in ground-glass nodules (p < 0.0001), and the difference was more pronounced at the lowest tube current (11.8 ± 5.9% compared with 21.3 ± 6.1%; p < 0.0001). The effect of IR was most pronounced for ground-glass nodules in the lowest CT tube current.
CONCLUSION: Lung nodule volumetry in low-dose CT by application of IR showed reliable accuracy in a phantom study. Lung nodule volumetry can be reliably applicable to all lung nodules including small, ground-glass nodules even in ultra-low-dose CT with application of IR. ADVANCES IN KNOWLEDGE: IR significantly improved the accuracy of lung nodule volumetry compared with FBP particularly for ground-glass (-630 HU) nodules. Volumetry in low-dose CT can be utilized in patient with lung nodule work-up, and IR has benefit for small, ground-glass lung nodules in low-dose CT.

Entities:  

Mesh:

Year:  2014        PMID: 25026866      PMCID: PMC4453132          DOI: 10.1259/bjr.20130644

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  32 in total

1.  New guidelines to evaluate the response to treatment in solid tumors. European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada.

Authors:  P Therasse; S G Arbuck; E A Eisenhauer; J Wanders; R S Kaplan; L Rubinstein; J Verweij; M Van Glabbeke; A T van Oosterom; M C Christian; S G Gwyther
Journal:  J Natl Cancer Inst       Date:  2000-02-02       Impact factor: 13.506

2.  Small pulmonary nodules: volume measurement at chest CT--phantom study.

Authors:  Jane P Ko; Henry Rusinek; Erika L Jacobs; James S Babb; Margrit Betke; Georgeann McGuinness; David P Naidich
Journal:  Radiology       Date:  2003-09       Impact factor: 11.105

3.  Volumetric measurement of synthetic lung nodules with multi-detector row CT: effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy.

Authors:  Jin Mo Goo; Trongtum Tongdee; Ranista Tongdee; Kwangjae Yeo; Charles F Hildebolt; Kyongtae T Bae
Journal:  Radiology       Date:  2005-06       Impact factor: 11.105

4.  Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners.

Authors:  Marco Das; Julia Ley-Zaporozhan; H A Gietema; Andre Czech; Georg Mühlenbruch; Andreas H Mahnken; Markus Katoh; Annemarie Bakai; Marcos Salganicoff; Stefan Diederich; Mathias Prokop; Hans-Ulrich Kauczor; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2007-01-06       Impact factor: 5.315

5.  Pulmonary nodule volumetric measurement variability as a function of CT slice thickness and nodule morphology.

Authors:  Myria Petrou; Leslie E Quint; Bin Nan; Laurence H Baker
Journal:  AJR Am J Roentgenol       Date:  2007-02       Impact factor: 3.959

Review 6.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

Review 7.  Noncalcified lung nodules: volumetric assessment with thoracic CT.

Authors:  Marios A Gavrielides; Lisa M Kinnard; Kyle J Myers; Nicholas Petrick
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

8.  Management of lung nodules detected by volume CT scanning.

Authors:  Rob J van Klaveren; Matthijs Oudkerk; Mathias Prokop; Ernst T Scholten; Kristiaan Nackaerts; Rene Vernhout; Carola A van Iersel; Karien A M van den Bergh; Susan van 't Westeinde; Carlijn van der Aalst; Erik Thunnissen; Dong Ming Xu; Ying Wang; Yingru Zhao; Hester A Gietema; Bart-Jan de Hoop; Harry J M Groen; Geertruida H de Bock; Peter van Ooijen; Carla Weenink; Johny Verschakelen; Jan-Willem J Lammers; Wim Timens; Dik Willebrand; Aryan Vink; Willem Mali; Harry J de Koning
Journal:  N Engl J Med       Date:  2009-12-03       Impact factor: 91.245

9.  New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1).

Authors:  E A Eisenhauer; P Therasse; J Bogaerts; L H Schwartz; D Sargent; R Ford; J Dancey; S Arbuck; S Gwyther; M Mooney; L Rubinstein; L Shankar; L Dodd; R Kaplan; D Lacombe; J Verweij
Journal:  Eur J Cancer       Date:  2009-01       Impact factor: 9.162

10.  Adaptive iterative dose reduction algorithm in CT: effect on image quality compared with filtered back projection in body phantoms of different sizes.

Authors:  Milim Kim; Jeong Min Lee; Jeong Hee Yoon; Hyoshin Son; Jin Woo Choi; Joon Koo Han; Byung Ihn Choi
Journal:  Korean J Radiol       Date:  2014-03-07       Impact factor: 3.500

View more
  18 in total

1.  Ultralow-dose CT with tin filtration for detection of solid and sub solid pulmonary nodules: a phantom study.

Authors:  Katharina Martini; Kai Higashigaito; Borna K Barth; Stephan Baumueller; Hatem Alkadhi; Thomas Frauenfelder
Journal:  Br J Radiol       Date:  2015-10-22       Impact factor: 3.039

2.  Volume estimation of multidensity nodules with thoracic computed tomography.

Authors:  Marios A Gavrielides; Qin Li; Rongping Zeng; Kyle J Myers; Berkman Sahiner; Nicholas Petrick
Journal:  J Med Imaging (Bellingham)       Date:  2016-01-29

3.  Ultra-low-dose CT with model-based iterative reconstruction (MBIR): detection of ground-glass nodules in an anthropomorphic phantom study.

Authors:  Cristiano Rampinelli; Daniela Origgi; Vittoria Vecchi; Luigi Funicelli; Sara Raimondi; Paul Deak; Massimo Bellomi
Journal:  Radiol Med       Date:  2015-02-06       Impact factor: 3.469

4.  Changes in quantitative parameters of pulmonary nonsolid nodule induced by lung inflation according to paired inspiratory and expiratory computed tomography imaging.

Authors:  Li Fan; QingChu Li; WenTing Tu; RuTan Chen; Yi Xia; Yu Pu; ZhaoBin Li; ShiYuan Liu
Journal:  Eur Radiol       Date:  2019-01-28       Impact factor: 5.315

5.  Variability in CT lung-nodule volumetry: Effects of dose reduction and reconstruction methods.

Authors:  Stefano Young; Hyun J Grace Kim; Moe Moe Ko; War War Ko; Carlos Flores; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

6.  Usefulness of model-based iterative reconstruction in semi-automatic volumetry for ground-glass nodules at ultra-low-dose CT: a phantom study.

Authors:  Shuki Maruyama; Yasuhiro Fukushima; Yuta Miyamae; Koji Koizumi
Journal:  Radiol Phys Technol       Date:  2018-02-10

7.  Current perspectives for the size measurement of screening-detected lung nodules.

Authors:  Hyungjin Kim; Chang Min Park
Journal:  J Thorac Dis       Date:  2018-03       Impact factor: 2.895

8.  Evaluation of T categories for pure ground-glass nodules with semi-automatic volumetry: is mass a better predictor of invasive part size than other volumetric parameters?

Authors:  Hyungjin Kim; Jin Mo Goo; Chang Min Park
Journal:  Eur Radiol       Date:  2018-04-30       Impact factor: 5.315

9.  Volumetric assessment of solid pulmonary nodules on ultralow-dose CT: a phantom study.

Authors:  Matthias Eberhard; Daniel Stocker; Gianluca Milanese; Katharina Martini; Thi Dan Linh Nguyen-Kim; Moritz C Wurnig; Thomas Frauenfelder; Stephan Baumueller
Journal:  J Thorac Dis       Date:  2019-08       Impact factor: 2.895

10.  Quantitative assessment of nonsolid pulmonary nodule volume with computed tomography in a phantom study.

Authors:  Marios A Gavrielides; Benjamin P Berman; Mark Supanich; Kurt Schultz; Qin Li; Nicholas Petrick; Rongping Zeng; Jenifer Siegelman
Journal:  Quant Imaging Med Surg       Date:  2017-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.