Literature DB >> 22894449

Uncertainty incorporated beam angle optimization for IMPT treatment planning.

Wenhua Cao1, Gino J Lim, Andrew Lee, Yupeng Li, Wei Liu, X Ronald Zhu, Xiaodong Zhang.   

Abstract

PURPOSE: Beam angle optimization (BAO) by far remains an important and challenging problem in external beam radiation therapy treatment planning. Conventional BAO algorithms discussed in previous studies all focused on photon-based therapies. Impact of BAO on proton therapy is important while proton therapy increasingly receives great interests. This study focuses on potential benefits of BAO on intensity-modulated proton therapy (IMPT) that recently began available to clinical cancer treatment.
METHODS: The authors have developed a novel uncertainty incorporated BAO algorithm for IMPT treatment planning in that IMPT plan quality is highly sensitive to uncertainties such as proton range and setup errors. A linear programming was used to optimize robust intensity maps to scenario-based uncertainties for an incident beam angle configuration. Unlike conventional intensity-modulated radiation therapy with photons (IMXT), the search space for IMPT treatment beam angles may be relatively small but optimizing an IMPT plan may require higher computational costs due to larger data size. Therefore, a deterministic local neighborhood search algorithm that only needs a very limited number of plan objective evaluations was used to optimize beam angles in IMPT treatment planning.
RESULTS: Three prostate cancer cases and two skull base chordoma cases were studied to demonstrate the dosimetric advantages and robustness of optimized beam angles from the proposed BAO algorithm. Two- to four-beam plans were optimized for prostate cases, and two- and three-beam plans were optimized for skull base cases. By comparing plans with conventional two parallel-opposed angles, all plans with optimized angles consistently improved sparing at organs at risks, i.e., rectum and femoral heads for prostate, brainstem for skull base, in either nominal dose distribution or uncertainty-based dose distributions. The efficiency of the BAO algorithm was demonstrated by comparing it with alternative methods including simulated annealing and genetic algorithm. The numbers of IMPT plan objective evaluations required were reduced by up to a factor of 5 while the same optimal angle plans were converged in selected comparisons.
CONCLUSIONS: Uncertainty incorporated BAO may introduce pronounced improvement of IMPT plan quality including dosimetric benefits and robustness over uncertainties, based on the five clinical studies in this paper. In addition, local search algorithms may be more efficient in finding optimal beam angles than global optimization approaches for IMPT BAO.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22894449      PMCID: PMC3422361          DOI: 10.1118/1.4737870

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  33 in total

1.  Automatic beam angle selection in IMRT planning using genetic algorithm.

Authors:  Yongjie Li; Jonathan Yao; Dezhong Yao
Journal:  Phys Med Biol       Date:  2004-05-21       Impact factor: 3.609

2.  Improvement of prostate treatment by anterior proton fields.

Authors:  Shikui Tang; Stefan Both; Hassan Bentefour; Jonathan J Paly; Zelig Tochner; Jason Efstathiou; Hsiao-Ming Lu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-11-30       Impact factor: 7.038

3.  Incorporating partial shining effects in proton pencil-beam dose calculation.

Authors:  Yupeng Li; Xiaodong Zhang; Mingfwu Lii; Narayan Sahoo; Ron X Zhu; Michael Gillin; Radhe Mohan
Journal:  Phys Med Biol       Date:  2008-01-10       Impact factor: 3.609

4.  Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning.

Authors:  Jan Unkelbach; Thomas Bortfeld; Benjamin C Martin; Martin Soukup
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

5.  Uncertainty reduction in intensity modulated proton therapy by inverse Monte Carlo treatment planning.

Authors:  Zdenek Morávek; Mark Rickhey; Matthias Hartmann; Ludwig Bogner
Journal:  Phys Med Biol       Date:  2009-07-22       Impact factor: 3.609

6.  Optimization of beam orientations in radiation therapy: some theoretical considerations.

Authors:  T Bortfeld; W Schlegel
Journal:  Phys Med Biol       Date:  1993-02       Impact factor: 3.609

7.  Application of fast simulated annealing to optimization of conformal radiation treatments.

Authors:  G S Mageras; R Mohan
Journal:  Med Phys       Date:  1993 May-Jun       Impact factor: 4.071

8.  Beam-orientation customization using an artificial neural network.

Authors:  C G Rowbottom; S Webb; M Oldham
Journal:  Phys Med Biol       Date:  1999-09       Impact factor: 3.609

9.  Beyond Gaussians: a study of single-spot modeling for scanning proton dose calculation.

Authors:  Yupeng Li; Ronald X Zhu; Narayan Sahoo; Aman Anand; Xiaodong Zhang
Journal:  Phys Med Biol       Date:  2012-02-01       Impact factor: 3.609

10.  Feasibility study of beam orientation class-solutions for prostate IMRT.

Authors:  Eduard Schreibmann; Lei Xing
Journal:  Med Phys       Date:  2004-10       Impact factor: 4.071

View more
  17 in total

1.  Automating proton treatment planning with beam angle selection using Bayesian optimization.

Authors:  Vicki T Taasti; Linda Hong; Jin Sup Andy Shim; Joseph O Deasy; Masoud Zarepisheh
Journal:  Med Phys       Date:  2020-05-27       Impact factor: 4.071

2.  Robust treatment planning with conditional value at risk chance constraints in intensity-modulated proton therapy.

Authors:  Yu An; Jianming Liang; Steven E Schild; Martin Bues; Wei Liu
Journal:  Med Phys       Date:  2017-01-03       Impact factor: 4.071

3.  Multifield optimization intensity modulated proton therapy for head and neck tumors: a translation to practice.

Authors:  Steven J Frank; James D Cox; Michael Gillin; Radhe Mohan; Adam S Garden; David I Rosenthal; G Brandon Gunn; Randal S Weber; Merrill S Kies; Jan S Lewin; Mark F Munsell; Matthew B Palmer; Narayan Sahoo; Xiaodong Zhang; Wei Liu; X Ronald Zhu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-05-24       Impact factor: 7.038

4.  Fraction-variant beam orientation optimization for intensity-modulated proton therapy.

Authors:  Wenbo Gu; Daniel O'Connor; Dan Ruan; Wei Zou; Lei Dong; Ke Sheng
Journal:  Med Phys       Date:  2020-08-02       Impact factor: 4.071

5.  Beam angle optimization using angular dependency of range variation assessed via water equivalent path length (WEPL) calculation for head and neck proton therapy.

Authors:  Jihun Kim; Yang-Kyun Park; Gregory Sharp; Paul Busse; Brian Winey
Journal:  Phys Med       Date:  2019-12-05       Impact factor: 2.685

6.  Incorporating deliverable monitor unit constraints into spot intensity optimization in intensity-modulated proton therapy treatment planning.

Authors:  Wenhua Cao; Gino Lim; Xiaoqiang Li; Yupeng Li; X Ronald Zhu; Xiaodong Zhang
Journal:  Phys Med Biol       Date:  2013-07-09       Impact factor: 3.609

7.  Proton energy optimization and reduction for intensity-modulated proton therapy.

Authors:  Wenhua Cao; Gino Lim; Li Liao; Yupeng Li; Shengpeng Jiang; Xiaoqiang Li; Heng Li; Kazumichi Suzuki; X Ronald Zhu; Daniel Gomez; Xiaodong Zhang
Journal:  Phys Med Biol       Date:  2014-10-08       Impact factor: 3.609

8.  Integrated beam orientation and scanning-spot optimization in intensity-modulated proton therapy for brain and unilateral head and neck tumors.

Authors:  Wenbo Gu; Daniel O'Connor; Dan Nguyen; Victoria Y Yu; Dan Ruan; Lei Dong; Ke Sheng
Journal:  Med Phys       Date:  2018-03-01       Impact factor: 4.071

9.  Risk-optimized proton therapy to minimize radiogenic second cancers.

Authors:  Laura A Rechner; John G Eley; Rebecca M Howell; Rui Zhang; Dragan Mirkovic; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2015-04-28       Impact factor: 3.609

10.  SDDRO-joint: simultaneous dose and dose rate optimization with the joint use of transmission beams and Bragg peaks for FLASH proton therapy.

Authors:  Yuting Lin; Bowen Lin; Shujun Fu; Michael M Folkerts; Eric Abel; Jeffrey Bradley; Hao Gao
Journal:  Phys Med Biol       Date:  2021-06-14       Impact factor: 4.174

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.