Literature DB >> 15214533

Automatic beam angle selection in IMRT planning using genetic algorithm.

Yongjie Li1, Jonathan Yao, Dezhong Yao.   

Abstract

The selection of suitable beam angles in external beam radiotherapy is at present generally based upon the experience of the human planner. The requirement to automatically select beam angles is particularly highlighted in intensity-modulated radiation therapy (IMRT), in which a smaller number of modulated beams is hoped to be used, in comparison with conformal radiotherapy. It has been proved by many researchers that the selection of suitable beam angles is most valuable for a plan with a small number of beams (< or = 5). In this paper an efficient method is presented to investigate how to improve the dose distributions by selecting suitable coplanar beam angles. In our automatic beam angle selection (ABAS) algorithm, the optimal coplanar beam angles correspond to the lowest objective function value of the dose distributions calculated using the intensity-modulated maps of this group of candidate beams. Due to the complexity of the problem and the large search space involved, the selection of beam angles and the optimization of intensity maps are treated as two separate processes and implemented iteratively. A genetic algorithm (GA) incorporated with an immunity operation is used to select suitable beam angles, and a conjugate gradient (CG) method is used to quickly optimize intensity maps for each selected beam combination based on a dose-based objective function. A pencil-beam-based three-dimensional (3D) full scatter convolution (FSC) algorithm is employed for the dose calculation. Two simulated cases with obvious optimal beam angles are used to verify the validity of the presented technique, and a more complicated case simulating a prostate tumour and two clinical cases are employed to test the efficiency of ABAS. The results show that ABAS is valid and efficient and can improve the dose distributions within a clinically acceptable computation time.

Entities:  

Mesh:

Year:  2004        PMID: 15214533     DOI: 10.1088/0031-9155/49/10/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Intensity modulated radiation therapy with field rotation--a time-varying fractionation study.

Authors:  Delal Dink; Mark P Langer; Ronald L Rardin; Joseph F Pekny; Gintaras V Reklaitis; Behlul Saka
Journal:  Health Care Manag Sci       Date:  2012-01-10

2.  Many-isocenter optimization for robotic radiotherapy.

Authors:  Qihui Lyu; Ryan Neph; Victoria Y Yu; Dan Ruan; Salime Boucher; Ke Sheng
Journal:  Phys Med Biol       Date:  2020-02-10       Impact factor: 3.609

Review 3.  From analytic inversion to contemporary IMRT optimization: radiation therapy planning revisited from a mathematical perspective.

Authors:  Yair Censor; Jan Unkelbach
Journal:  Phys Med       Date:  2011-05-25       Impact factor: 2.685

4.  Parallel beamlet dose calculation via beamlet contexts in a distributed multi-GPU framework.

Authors:  Ryan Neph; Cheng Ouyang; John Neylon; Youming Yang; Ke Sheng
Journal:  Med Phys       Date:  2019-06-30       Impact factor: 4.071

5.  Uncertainty incorporated beam angle optimization for IMPT treatment planning.

Authors:  Wenhua Cao; Gino J Lim; Andrew Lee; Yupeng Li; Wei Liu; X Ronald Zhu; Xiaodong Zhang
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

6.  A hierarchical evolutionary algorithm for multiobjective optimization in IMRT.

Authors:  Clay Holdsworth; Minsun Kim; Jay Liao; Mark H Phillips
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

7.  Standardized beam bouquets for lung IMRT planning.

Authors:  Lulin Yuan; Q Jackie Wu; Fangfang Yin; Ying Li; Yang Sheng; Christopher R Kelsey; Yaorong Ge
Journal:  Phys Med Biol       Date:  2015-02-06       Impact factor: 3.609

8.  A data-driven approach to optimal beam/arc angle selection for liver stereotactic body radiation therapy treatment planning.

Authors:  Yang Sheng; Taoran Li; Yaorong Ge; Hui Lin; Wentao Wang; Lulin Yuan; Q Jackie Wu
Journal:  Quant Imaging Med Surg       Date:  2021-12

9.  Integrated beam orientation and scanning-spot optimization in intensity-modulated proton therapy for brain and unilateral head and neck tumors.

Authors:  Wenbo Gu; Daniel O'Connor; Dan Nguyen; Victoria Y Yu; Dan Ruan; Lei Dong; Ke Sheng
Journal:  Med Phys       Date:  2018-03-01       Impact factor: 4.071

Review 10.  Machine learning applications in radiation oncology.

Authors:  Matthew Field; Nicholas Hardcastle; Michael Jameson; Noel Aherne; Lois Holloway
Journal:  Phys Imaging Radiat Oncol       Date:  2021-06-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.