Literature DB >> 22297324

Beyond Gaussians: a study of single-spot modeling for scanning proton dose calculation.

Yupeng Li1, Ronald X Zhu, Narayan Sahoo, Aman Anand, Xiaodong Zhang.   

Abstract

Active spot scanning proton therapy is becoming increasingly adopted by proton therapy centers worldwide. Unlike passive-scattering proton therapy, active spot scanning proton therapy, especially intensity-modulated proton therapy, requires proper modeling of each scanning spot to ensure accurate computation of the total dose distribution contributed from a large number of spots. During commissioning of the spot scanning gantry at the Proton Therapy Center in Houston, it was observed that the long-range scattering protons in a medium may have been inadequately modeled for high-energy beams by a commercial treatment planning system, which could lead to incorrect prediction of field size effects on dose output. In this study, we developed a pencil beam algorithm for scanning proton dose calculation by focusing on properly modeling individual scanning spots. All modeling parameters required by the pencil beam algorithm can be generated based solely on a few sets of measured data. We demonstrated that low-dose halos in single-spot profiles in the medium could be adequately modeled with the addition of a modified Cauchy-Lorentz distribution function to a double-Gaussian function. The field size effects were accurately computed at all depths and field sizes for all energies, and good dose accuracy was also achieved for patient dose verification. The implementation of the proposed pencil beam algorithm also enabled us to study the importance of different modeling components and parameters at various beam energies. The results of this study may be helpful in improving dose calculation accuracy and simplifying beam commissioning and treatment planning processes for spot scanning proton therapy.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22297324      PMCID: PMC3805838          DOI: 10.1088/0031-9155/57/4/983

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  22 in total

1.  Parameterization of multiple Bragg curves for scanning proton beams using simultaneous fitting of multiple curves.

Authors:  Xiaodong Zhang; Wei Liu; Yupeng Li; Xiaoqiang Li; Michelle Quan; Radhe Mohan; Aman Anand; Narayan Sahoo; Michael Gillin; Xiaorong R Zhu
Journal:  Phys Med Biol       Date:  2011-11-16       Impact factor: 3.609

2.  Experimental characterization of the low-dose envelope of spot scanning proton beams.

Authors:  Gabriel O Sawakuchi; X Ronald Zhu; Falk Poenisch; Kazumichi Suzuki; George Ciangaru; Uwe Titt; Aman Anand; Radhe Mohan; Michael T Gillin; Narayan Sahoo
Journal:  Phys Med Biol       Date:  2010-05-28       Impact factor: 3.609

3.  Proton dose calculation based on in-air fluence measurements.

Authors:  Barbara Schaffner
Journal:  Phys Med Biol       Date:  2008-02-22       Impact factor: 3.609

4.  Field-size effect of physical doses in carbon-ion scanning using range shifter plates.

Authors:  Taku Inaniwa; Takuji Furukawa; Ai Nagano; Shinji Sato; Naoya Saotome; Koji Noda; Tatsuaki Kanai
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

5.  Computation of doses for large-angle Coulomb scattering of proton pencil beams.

Authors:  George Ciangaru; Narayan Sahoo; X Ronald Zhu; Gabriel O Sawakuchi; Michael T Gillin
Journal:  Phys Med Biol       Date:  2009-11-20       Impact factor: 3.609

6.  Commissioning of the discrete spot scanning proton beam delivery system at the University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston.

Authors:  Michael T Gillin; Narayan Sahoo; Martin Bues; George Ciangaru; Gabriel Sawakuchi; Falk Poenisch; Bijan Arjomandy; Craig Martin; Uwe Titt; Kazumichi Suzuki; Alfred R Smith; X Ronald Zhu
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

7.  A Monte Carlo pencil beam scanning model for proton treatment plan simulation using GATE/GEANT4.

Authors:  L Grevillot; D Bertrand; F Dessy; N Freud; D Sarrut
Journal:  Phys Med Biol       Date:  2011-07-26       Impact factor: 3.609

8.  Intensity-modulated proton therapy reduces the dose to normal tissue compared with intensity-modulated radiation therapy or passive scattering proton therapy and enables individualized radical radiotherapy for extensive stage IIIB non-small-cell lung cancer: a virtual clinical study.

Authors:  Xiaodong Zhang; Yupeng Li; Xiaoning Pan; Li Xiaoqiang; Radhe Mohan; Ritsuko Komaki; James D Cox; Joe Y Chang
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-08-05       Impact factor: 7.038

9.  Postoperative proton radiotherapy for localized and locoregional breast cancer: potential for clinically relevant improvements?

Authors:  Carmen Ares; Shaka Khan; Anne M Macartain; Jürg Heuberger; Gudrun Goitein; Guenther Gruber; Gerd Lutters; Eugen B Hug; Stephan Bodis; Antony J Lomax
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-07-15       Impact factor: 7.038

10.  Proton versus photon radiotherapy for common pediatric brain tumors: comparison of models of dose characteristics and their relationship to cognitive function.

Authors:  Thomas E Merchant; Chia-Ho Hua; Hemant Shukla; Xiaofei Ying; Simeon Nill; Uwe Oelfke
Journal:  Pediatr Blood Cancer       Date:  2008-07       Impact factor: 3.167

View more
  25 in total

1.  Robust treatment planning with conditional value at risk chance constraints in intensity-modulated proton therapy.

Authors:  Yu An; Jianming Liang; Steven E Schild; Martin Bues; Wei Liu
Journal:  Med Phys       Date:  2017-01-03       Impact factor: 4.071

2.  On the interplay effects with proton scanning beams in stage III lung cancer.

Authors:  Yupeng Li; Laleh Kardar; Xiaoqiang Li; Heng Li; Wenhua Cao; Joe Y Chang; Li Liao; Ronald X Zhu; Narayan Sahoo; Michael Gillin; Zhongxing Liao; Ritsuko Komaki; James D Cox; Gino Lim; Xiaodong Zhang
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

3.  Dosimetric benefits of robust treatment planning for intensity modulated proton therapy for base-of-skull cancers.

Authors:  Wei Liu; Radhe Mohan; Peter Park; Zhong Liu; Heng Li; Xiaoqiang Li; Yupeng Li; Richard Wu; Narayan Sahoo; Lei Dong; X Ronald Zhu; David R Grosshans
Journal:  Pract Radiat Oncol       Date:  2014-01-14

4.  Reducing Dose Uncertainty for Spot-Scanning Proton Beam Therapy of Moving Tumors by Optimizing the Spot Delivery Sequence.

Authors:  Heng Li; X Ronald Zhu; Xiaodong Zhang
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-06-18       Impact factor: 7.038

5.  Evaluation and mitigation of the interplay effects of intensity modulated proton therapy for lung cancer in a clinical setting.

Authors:  Laleh Kardar; Yupeng Li; Xiaoqiang Li; Heng Li; Wenhua Cao; Joe Y Chang; Li Liao; Ronald X Zhu; Narayan Sahoo; Michael Gillin; Zhongxing Liao; Ritsuko Komaki; James D Cox; Gino Lim; Xiaodong Zhang
Journal:  Pract Radiat Oncol       Date:  2014-08-12

6.  Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer.

Authors:  Wei Liu; Steven E Schild; Joe Y Chang; Zhongxing Liao; Yu-Hui Chang; Zhifei Wen; Jiajian Shen; Joshua B Stoker; Xiaoning Ding; Yanle Hu; Narayan Sahoo; Michael G Herman; Carlos Vargas; Sameer Keole; William Wong; Martin Bues
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-11-10       Impact factor: 7.038

7.  Incorporating deliverable monitor unit constraints into spot intensity optimization in intensity-modulated proton therapy treatment planning.

Authors:  Wenhua Cao; Gino Lim; Xiaoqiang Li; Yupeng Li; X Ronald Zhu; Xiaodong Zhang
Journal:  Phys Med Biol       Date:  2013-07-09       Impact factor: 3.609

8.  Uncertainty incorporated beam angle optimization for IMPT treatment planning.

Authors:  Wenhua Cao; Gino J Lim; Andrew Lee; Yupeng Li; Wei Liu; X Ronald Zhu; Xiaodong Zhang
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

9.  Quantification of proton dose calculation accuracy in the lung.

Authors:  Clemens Grassberger; Juliane Daartz; Stephen Dowdell; Thomas Ruggieri; Greg Sharp; Harald Paganetti
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-04-11       Impact factor: 7.038

10.  Commissioning dose computation models for spot scanning proton beams in water for a commercially available treatment planning system.

Authors:  X R Zhu; F Poenisch; M Lii; G O Sawakuchi; U Titt; M Bues; X Song; X Zhang; Y Li; G Ciangaru; H Li; M B Taylor; K Suzuki; R Mohan; M T Gillin; N Sahoo
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.