Temporal and spectral imaging with micro-CT.

Samuel M Johnston1, G Allan Johnson, Cristian T Badea.   

Abstract

PURPOSE: Micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with dual source micro-CT.
METHODS: The approach entails a retrospectively gated dual energy scan with optimized filters and voltages, and a series of computational operations to reconstruct the data. Projection interpolation and five-dimensional bilateral filtration (three spatial dimensions + time + energy) are used to reduce noise and artifacts associated with retrospective gating. We reconstruct separate volumes corresponding to different cardiac phases and apply a linear transformation to decompose these volumes into components representing concentrations of water and iodine. Since the resulting material images are still compromised by noise, we improve their quality in an iterative process that minimizes the discrepancy between the original acquired projections and the projections predicted by the reconstructed volumes. The values in the voxels of each of the reconstructed volumes represent the coefficients of linear combinations of basis functions over time and energy. We have implemented the reconstruction algorithm on a graphics processing unit (GPU) with CUDA. We tested the utility of the technique in simulations and applied the technique in an in vivo scan of a C57BL∕6 mouse injected with blood pool contrast agent at a dose of 0.01 ml∕g body weight. Postreconstruction, at each cardiac phase in the iodine images, we segmented the left ventricle and computed its volume. Using the maximum and minimum volumes in the left ventricle, we calculated the stroke volume, the ejection fraction, and the cardiac output.
RESULTS: Our proposed method produces five-dimensional volumetric images that distinguish different materials at different points in time, and can be used to segment regions containing iodinated blood and compute measures of cardiac function.
CONCLUSIONS: We believe this combined spectral and temporal imaging technique will be useful for future studies of cardiopulmonary disease in small animals.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22894420      PMCID: PMC3416878          DOI: 10.1118/1.4736809

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.506


  29 in total

1.  Monotonic algorithms for transmission tomography.

Authors:  H Erdoğan; J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1999-09       Impact factor: 10.048

2.  Spektr: a computational tool for x-ray spectral analysis and imaging system optimization.

Authors:  J H Siewerdsen; A M Waese; D J Moseley; S Richard; D A Jaffray
Journal:  Med Phys       Date:  2004-11       Impact factor: 4.071

3.  An optimal radial profile order based on the Golden Ratio for time-resolved MRI.

Authors:  Stefanie Winkelmann; Tobias Schaeffter; Thomas Koehler; Holger Eggers; Olaf Doessel
Journal:  IEEE Trans Med Imaging       Date:  2007-01       Impact factor: 10.048

4.  Fast retrospectively gated quantitative four-dimensional (4D) cardiac micro computed tomography imaging of free-breathing mice.

Authors:  Maria Drangova; Nancy L Ford; Sarah A Detombe; Andrew R Wheatley; David W Holdsworth
Journal:  Invest Radiol       Date:  2007-02       Impact factor: 6.016

5.  Implementation of dual- and triple-energy cone-beam micro-CT for postreconstruction material decomposition.

Authors:  P V Granton; S I Pollmann; N L Ford; M Drangova; D W Holdsworth
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

6.  First performance evaluation of a dual-source CT (DSCT) system.

Authors:  Thomas G Flohr; Cynthia H McCollough; Herbert Bruder; Martin Petersilka; Klaus Gruber; Christoph Süss; Michael Grasruck; Karl Stierstorfer; Bernhard Krauss; Rainer Raupach; Andrew N Primak; Axel Küttner; Stefan Achenbach; Christoph Becker; Andreas Kopp; Bernd M Ohnesorge
Journal:  Eur Radiol       Date:  2005-12-10       Impact factor: 5.315

7.  An iterative method for tomographic x-ray perfusion estimation in a decomposition model-based approach.

Authors:  Christoph Neukirchen; Marco Giordano; Steffen Wiesner
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

8.  Gadolinium as a CT contrast agent: assessment in a porcine model.

Authors:  D S Gierada; K T Bae
Journal:  Radiology       Date:  1999-03       Impact factor: 11.105

9.  Low-dose cardio-respiratory phase-correlated cone-beam micro-CT of small animals.

Authors:  Stefan Sawall; Frank Bergner; Robert Lapp; Markus Mronz; Marek Karolczak; Andreas Hess; Marc Kachelriess
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

10.  Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart.

Authors:  Marc Kachelriess; Dirk-Alexander Sennst; Wolfgang Maxlmoser; Willi A Kalender
Journal:  Med Phys       Date:  2002-07       Impact factor: 4.071

View more
  11 in total

1.  Dual-energy cone-beam CT with a flat-panel detector: effect of reconstruction algorithm on material classification.

Authors:  W Zbijewski; G J Gang; J Xu; A S Wang; J W Stayman; K Taguchi; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

2.  Spectral diffusion: an algorithm for robust material decomposition of spectral CT data.

Authors:  Darin P Clark; Cristian T Badea
Journal:  Phys Med Biol       Date:  2014-10-08       Impact factor: 3.609

3.  Establishment of an orthotopic transplantation tumor model of hepatocellular carcinoma in mice.

Authors:  Gui-Jun Zhao; Li-Xia Xu; Eagle S H Chu; Ning Zhang; Jia-Yun Shen; Alatangaole Damirin; Xiao-Xing Li
Journal:  World J Gastroenterol       Date:  2012-12-21       Impact factor: 5.742

4.  Anatomical and functional imaging of myocardial infarction in mice using micro-CT and eXIA 160 contrast agent.

Authors:  Jeffrey R Ashton; Nicholas Befera; Darin Clark; Yi Qi; Lan Mao; Howard A Rockman; G Allan Johnson; Cristian T Badea
Journal:  Contrast Media Mol Imaging       Date:  2014 Mar-Apr       Impact factor: 3.161

Review 5.  Modelling the physics in the iterative reconstruction for transmission computed tomography.

Authors:  Johan Nuyts; Bruno De Man; Jeffrey A Fessler; Wojciech Zbijewski; Freek J Beekman
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

6.  Spectrotemporal CT data acquisition and reconstruction at low dose.

Authors:  Darin P Clark; Chang-Lung Lee; David G Kirsch; Cristian T Badea
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

7.  Comparison of 4D-microSPECT and microCT for murine cardiac function.

Authors:  Nicholas T Befera; Cristian T Badea; G Allan Johnson
Journal:  Mol Imaging Biol       Date:  2014-04       Impact factor: 3.488

Review 8.  Micro-CT of rodents: state-of-the-art and future perspectives.

Authors:  D P Clark; C T Badea
Journal:  Phys Med       Date:  2014-06-26       Impact factor: 2.685

Review 9.  Advance of molecular imaging technology and targeted imaging agent in imaging and therapy.

Authors:  Zhi-Yi Chen; Yi-Xiang Wang; Yan Lin; Jin-Shan Zhang; Feng Yang; Qiu-Lan Zhou; Yang-Ying Liao
Journal:  Biomed Res Int       Date:  2014-02-13       Impact factor: 3.411

10.  A LabVIEW Platform for Preclinical Imaging Using Digital Subtraction Angiography and Micro-CT.

Authors:  Cristian T Badea; Laurence W Hedlund; G Allan Johnson
Journal:  J Med Eng       Date:  2013-02-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.