Literature DB >> 24523061

Anatomical and functional imaging of myocardial infarction in mice using micro-CT and eXIA 160 contrast agent.

Jeffrey R Ashton1, Nicholas Befera, Darin Clark, Yi Qi, Lan Mao, Howard A Rockman, G Allan Johnson, Cristian T Badea.   

Abstract

Noninvasive small animal imaging techniques are essential for evaluation of cardiac disease and potential therapeutics. A novel preclinical iodinated contrast agent called eXIA 160 has recently been developed, which has been evaluated for micro-CT cardiac imaging. eXIA 160 creates strong contrast between blood and tissue immediately after its injection and is subsequently taken up by the myocardium and other metabolically active tissues over time. We focus on these properties of eXIA and show its use in imaging myocardial infarction in mice. Five C57BL/6 mice were imaged ~2 weeks after left anterior descending coronary artery ligation. Six C57BL/6 mice were used as controls. Immediately after injection of eXIA 160, an enhancement difference between blood and myocardium of ~340 HU enabled cardiac function estimation via 4D micro-CT scanning with retrospective gating. Four hours post-injection, the healthy perfused myocardium had a contrast difference of ~140 HU relative to blood while the infarcted myocardium showed no enhancement. These differences allowed quantification of infarct size via dual-energy micro-CT. In vivo micro-SPECT imaging and ex vivo triphenyl tetrazolium chloride (TTC) staining provided validation for the micro-CT findings. Root mean squared error of infarct measurements was 2.7% between micro-CT and SPECT, and 4.7% between micro-CT and TTC. Thus, micro-CT with eXIA 160 can be used to provide both morphological and functional data for preclinical studies evaluating myocardial infarction and potential therapies. Further studies are warranted to study the potential use of eXIA 160 as a CT molecular imaging tool for other metabolically active tissues in the mouse.
Copyright © 2014 John Wiley & Sons, Ltd.

Entities:  

Keywords:  contrast agent; imaging; micro-CT; myocardial infarction

Mesh:

Substances:

Year:  2014        PMID: 24523061      PMCID: PMC4017375          DOI: 10.1002/cmmi.1557

Source DB:  PubMed          Journal:  Contrast Media Mol Imaging        ISSN: 1555-4309            Impact factor:   3.161


  19 in total

1.  Evaluation of eXIA 160 cardiac-related enhancement in C57BL/6 and BALB/c mice using micro-CT.

Authors:  Sarah A Detombe; Joy Dunmore-Buyze; Maria Drangova
Journal:  Contrast Media Mol Imaging       Date:  2012 Mar-Apr       Impact factor: 3.161

2.  Monte carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom.

Authors:  Richard Taschereau; Patrick L Chow; Arion F Chatziioannou
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

3.  Dual-energy micro-CT of the rodent lung.

Authors:  C T Badea; X Guo; D Clark; S M Johnston; C D Marshall; C A Piantadosi
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2012-03-16       Impact factor: 5.464

4.  Lipid-based blood-pool CT imaging of the liver.

Authors:  J P Weichert; F T Lee; M A Longino; S G Chosy; R E Counsell
Journal:  Acad Radiol       Date:  1998-04       Impact factor: 3.173

5.  Registration-based segmentation of murine 4D cardiac micro-CT data using symmetric normalization.

Authors:  Darin Clark; Alexandra Badea; Yilin Liu; G Allan Johnson; Cristian T Badea
Journal:  Phys Med Biol       Date:  2012-09-13       Impact factor: 3.609

6.  Competitive displacement of phosphoinositide 3-kinase from beta-adrenergic receptor kinase-1 improves postinfarction adverse myocardial remodeling.

Authors:  Antonio Curcio; Takahisa Noma; Sathyamangla V Naga Prasad; Matthew J Wolf; Anthony Lemaire; Cinzia Perrino; Lan Mao; Howard A Rockman
Journal:  Am J Physiol Heart Circ Physiol       Date:  2006-05-12       Impact factor: 4.733

7.  Low-dose cardio-respiratory phase-correlated cone-beam micro-CT of small animals.

Authors:  Stefan Sawall; Frank Bergner; Robert Lapp; Markus Mronz; Marek Karolczak; Andreas Hess; Marc Kachelriess
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

8.  4-D micro-CT of the mouse heart.

Authors:  Cristian T Badea; Boma Fubara; Laurence W Hedlund; G Allan Johnson
Journal:  Mol Imaging       Date:  2005 Apr-Jun       Impact factor: 4.488

9.  A registration based approach for 4D cardiac micro-CT using combined prospective and retrospective gating.

Authors:  Cristian T Badea; Eduard Schreibmann; Tim Fox
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

10.  Temporal and spectral imaging with micro-CT.

Authors:  Samuel M Johnston; G Allan Johnson; Cristian T Badea
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.506

View more
  19 in total

1.  3D MicroCT spatial and temporal characterization of thoracic aorta perivascular adipose tissue and plaque volumes in the ApoE-/- mouse model.

Authors:  Erin Faight; Kostas Verdelis; Joseph M Ahearn; Kelly J Shields
Journal:  Adipocyte       Date:  2018-08-09       Impact factor: 4.534

2.  Overcoming detector limitations of x-ray photon counting for preclinical microcomputed tomography.

Authors:  Matthew Holbrook; Darin P Clark; Cristian T Badea
Journal:  J Med Imaging (Bellingham)       Date:  2018-08-24

3.  [Establishment of a rabbit model of small diameter vascular graft replacement].

Authors:  Jia-Qing Zhang; Kun-Tang Chen; Fu-Wei Zhang; Shao-Bin Li; Yuan-Zhou Wu; Jing Feng; Wu-Jun Wang; Yu-Sheng Yan
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2017-05-20

4.  Spectral diffusion: an algorithm for robust material decomposition of spectral CT data.

Authors:  Darin P Clark; Cristian T Badea
Journal:  Phys Med Biol       Date:  2014-10-08       Impact factor: 3.609

5.  Hybrid spectral CT reconstruction.

Authors:  Darin P Clark; Cristian T Badea
Journal:  PLoS One       Date:  2017-07-06       Impact factor: 3.240

Review 6.  Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

Authors:  Benjamin M Yeh; Paul F FitzGerald; Peter M Edic; Jack W Lambert; Robert E Colborn; Michael E Marino; Paul M Evans; Jeannette C Roberts; Zhen J Wang; Margaret J Wong; Peter J Bonitatibus
Journal:  Adv Drug Deliv Rev       Date:  2016-09-09       Impact factor: 15.470

7.  A neural network-based method for spectral distortion correction in photon counting x-ray CT.

Authors:  Mengheng Touch; Darin P Clark; William Barber; Cristian T Badea
Journal:  Phys Med Biol       Date:  2016-07-29       Impact factor: 3.609

8.  Spectrotemporal CT data acquisition and reconstruction at low dose.

Authors:  Darin P Clark; Chang-Lung Lee; David G Kirsch; Cristian T Badea
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

Review 9.  Micro-CT of rodents: state-of-the-art and future perspectives.

Authors:  D P Clark; C T Badea
Journal:  Phys Med       Date:  2014-06-26       Impact factor: 2.685

10.  Functional imaging of tumor vasculature using iodine and gadolinium-based nanoparticle contrast agents: a comparison of spectral micro-CT using energy integrating and photon counting detectors.

Authors:  C T Badea; D P Clark; M Holbrook; M Srivastava; Y Mowery; K B Ghaghada
Journal:  Phys Med Biol       Date:  2019-03-12       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.