Literature DB >> 25296173

Spectral diffusion: an algorithm for robust material decomposition of spectral CT data.

Darin P Clark1, Cristian T Badea.   

Abstract

Clinical successes with dual energy CT, aggressive development of energy discriminating x-ray detectors, and novel, target-specific, nanoparticle contrast agents promise to establish spectral CT as a powerful functional imaging modality. Common to all of these applications is the need for a material decomposition algorithm which is robust in the presence of noise. Here, we develop such an algorithm which uses spectrally joint, piecewise constant kernel regression and the split Bregman method to iteratively solve for a material decomposition which is gradient sparse, quantitatively accurate, and minimally biased. We call this algorithm spectral diffusion because it integrates structural information from multiple spectral channels and their corresponding material decompositions within the framework of diffusion-like denoising algorithms (e.g. anisotropic diffusion, total variation, bilateral filtration). Using a 3D, digital bar phantom and a material sensitivity matrix calibrated for use with a polychromatic x-ray source, we quantify the limits of detectability (CNR = 5) afforded by spectral diffusion in the triple-energy material decomposition of iodine (3.1 mg mL(-1)), gold (0.9 mg mL(-1)), and gadolinium (2.9 mg mL(-1)) concentrations. We then apply spectral diffusion to the in vivo separation of these three materials in the mouse kidneys, liver, and spleen.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25296173      PMCID: PMC4210864          DOI: 10.1088/0031-9155/59/21/6445

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  26 in total

1.  Kernel regression for image processing and reconstruction.

Authors:  Hiroyuki Takeda; Sina Farsiu; Peyman Milanfar
Journal:  IEEE Trans Image Process       Date:  2007-02       Impact factor: 10.856

2.  Dual-energy micro-CT of the rodent lung.

Authors:  C T Badea; X Guo; D Clark; S M Johnston; C D Marshall; C A Piantadosi
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2012-03-16       Impact factor: 5.464

Review 3.  Multifunctional theranostic gold nanoparticles for targeted CT imaging and photothermal therapy.

Authors:  Taeyjuana Curry; Raoul Kopelman; Malka Shilo; Rachela Popovtzer
Journal:  Contrast Media Mol Imaging       Date:  2014 Jan-Feb       Impact factor: 3.161

4.  Iterative image-domain decomposition for dual-energy CT.

Authors:  Tianye Niu; Xue Dong; Michael Petrongolo; Lei Zhu
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

5.  Denoising of 4D Cardiac Micro-CT Data Using Median-Centric Bilateral Filtration.

Authors:  D Clark; G A Johnson; C T Badea
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-02-23

6.  Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM).

Authors:  Hao Gao; Hengyong Yu; Stanley Osher; Ge Wang
Journal:  Inverse Probl       Date:  2011-11-01       Impact factor: 2.407

7.  Anatomical and functional imaging of myocardial infarction in mice using micro-CT and eXIA 160 contrast agent.

Authors:  Jeffrey R Ashton; Nicholas Befera; Darin Clark; Yi Qi; Lan Mao; Howard A Rockman; G Allan Johnson; Cristian T Badea
Journal:  Contrast Media Mol Imaging       Date:  2014 Mar-Apr       Impact factor: 3.161

8.  Dual-energy computed tomography imaging of atherosclerotic plaques in a mouse model using a liposomal-iodine nanoparticle contrast agent.

Authors:  Rohan Bhavane; Cristian Badea; Ketan B Ghaghada; Darin Clark; Deborah Vela; Anoosha Moturu; Akshaya Annapragada; G Allan Johnson; James T Willerson; Ananth Annapragada
Journal:  Circ Cardiovasc Imaging       Date:  2013-01-24       Impact factor: 7.792

9.  T1 relaxivity of core-encapsulated gadolinium liposomal contrast agents--effect of liposome size and internal gadolinium concentration.

Authors:  Ketan Ghaghada; Catherine Hawley; Keigo Kawaji; Ananth Annapragada; Srinivasan Mukundan
Journal:  Acad Radiol       Date:  2008-10       Impact factor: 3.173

10.  Dual-energy micro-computed tomography imaging of radiation-induced vascular changes in primary mouse sarcomas.

Authors:  Everett J Moding; Darin P Clark; Yi Qi; Yifan Li; Yan Ma; Ketan Ghaghada; G Allan Johnson; David G Kirsch; Cristian T Badea
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-11-01       Impact factor: 7.038

View more
  14 in total

1.  TICMR: Total Image Constrained Material Reconstruction via Nonlocal Total Variation Regularization for Spectral CT.

Authors:  Jiulong Liu; Huanjun Ding; Sabee Molloi; Xiaoqun Zhang; Hao Gao
Journal:  IEEE Trans Med Imaging       Date:  2016-07-07       Impact factor: 10.048

Review 2.  Nanoparticle contrast agents for X-ray imaging applications.

Authors:  Jessica C Hsu; Lenitza M Nieves; Oshra Betzer; Tamar Sadan; Peter B Noël; Rachela Popovtzer; David P Cormode
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2020-05-22

3.  Iterative reconstruction for dual energy CT with an average image-induced nonlocal means regularization.

Authors:  Houjin Zhang; Dong Zeng; Jiahui Lin; Hao Zhang; Zhaoying Bian; Jing Huang; Yuanyuan Gao; Shanli Zhang; Hua Zhang; Qianjin Feng; Zhengrong Liang; Wufan Chen; Jianhua Ma
Journal:  Phys Med Biol       Date:  2017-05-04       Impact factor: 3.609

4.  Hybrid spectral CT reconstruction.

Authors:  Darin P Clark; Cristian T Badea
Journal:  PLoS One       Date:  2017-07-06       Impact factor: 3.240

5.  An effective noise reduction method for multi-energy CT images that exploit spatio-spectral features.

Authors:  Zhoubo Li; Shuai Leng; Lifeng Yu; Armando Manduca; Cynthia H McCollough
Journal:  Med Phys       Date:  2017-04-12       Impact factor: 4.071

6.  Evaluation of spectral photon counting computed tomography K-edge imaging for determination of gold nanoparticle biodistribution in vivo.

Authors:  Salim Si-Mohamed; David P Cormode; Daniel Bar-Ness; Monica Sigovan; Pratap C Naha; Jean-Baptiste Langlois; Lara Chalabreysse; Philippe Coulon; Ira Blevis; Ewald Roessl; Klaus Erhard; Loic Boussel; Philippe Douek
Journal:  Nanoscale       Date:  2017-11-30       Impact factor: 7.790

7.  A neural network-based method for spectral distortion correction in photon counting x-ray CT.

Authors:  Mengheng Touch; Darin P Clark; William Barber; Cristian T Badea
Journal:  Phys Med Biol       Date:  2016-07-29       Impact factor: 3.609

8.  Deep-learning-based direct inversion for material decomposition.

Authors:  Hao Gong; Shengzhen Tao; Kishore Rajendran; Wei Zhou; Cynthia H McCollough; Shuai Leng
Journal:  Med Phys       Date:  2020-10-30       Impact factor: 4.071

9.  Spectrotemporal CT data acquisition and reconstruction at low dose.

Authors:  Darin P Clark; Chang-Lung Lee; David G Kirsch; Cristian T Badea
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

10.  Image-domain Material Decomposition for Spectral CT using a Generalized Dictionary Learning.

Authors:  Weiwen Wu; Peijun Chen; Shaoyu Wang; Varut Vardhanabhuti; Fenglin Liu; Hengyong Yu
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-05-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.