Literature DB >> 15587659

Spektr: a computational tool for x-ray spectral analysis and imaging system optimization.

J H Siewerdsen1, A M Waese, D J Moseley, S Richard, D A Jaffray.   

Abstract

A set of computational tools are presented that allow convenient calculation of x-ray spectra, selection of elemental and compound filters, and calculation of beam quality characteristics, such as half-value layer, mR/mAs, and fluence per unit exposure. The TASMIP model of Boone and Seibert is adapted to a library of high-level language (Matlab) functions and shown to agree with experimental measurements across a wide range of kVp and beam filtration. Modeling of beam filtration is facilitated by a convenient, extensible database of mass and mass-energy attenuation coefficients compiled from the National Institute of Standards and Technology. The functions and database were integrated in a graphical user interface and made available online at http:// www.aip.org/epaps/epaps.html. The functionality of the toolset and potential for investigation of imaging system optimization was illustrated in theoretical calculations of imaging performance across a broad range of kVp, filter material type, and filter thickness for direct and indirect-detection flat-panel imagers. The calculations reveal a number of nontrivial effects in the energy response of such detectors that may not have been guessed from simple K-edge filter techniques, and point to a variety of compelling hypotheses regarding choice of beam filtration that warrant future investigation.

Mesh:

Year:  2004        PMID: 15587659     DOI: 10.1118/1.1758350

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  65 in total

1.  Antiscatter grids in mobile C-arm cone-beam CT: effect on image quality and dose.

Authors:  S Schafer; J W Stayman; W Zbijewski; C Schmidgunst; G Kleinszig; J H Siewerdsen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging.

Authors:  P Prakash; W Zbijewski; G J Gang; Y Ding; J W Stayman; J Yorkston; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  Beyond noise power in 3D computed tomography: the local NPS and off-diagonal elements of the Fourier domain covariance matrix.

Authors:  Angel R Pineda; Daniel J Tward; Antonio Gonzalez; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

4.  Anatomical background and generalized detectability in tomosynthesis and cone-beam CT.

Authors:  G J Gang; D J Tward; J Lee; J H Siewerdsen
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

5.  Optimization of an on-board imaging system for extremely rapid radiation therapy.

Authors:  Erica M Cherry Kemmerling; Meng Wu; He Yang; Peter G Maxim; Billy W Loo; Rebecca Fahrig
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

6.  Lung imaging in rodents using dual energy micro-CT.

Authors:  C T Badea; X Guo; D Clark; S M Johnston; C Marshall; C Piantadosi
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-04-03

7.  Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT.

Authors:  Daniel J Tward; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

8.  The piecewise-linear dynamic attenuator reduces the impact of count rate loss with photon-counting detectors.

Authors:  Scott S Hsieh; Norbert J Pelc
Journal:  Phys Med Biol       Date:  2014-05-13       Impact factor: 3.609

9.  Multiresolution iterative reconstruction in high-resolution extremity cone-beam CT.

Authors:  Qian Cao; Wojciech Zbijewski; Alejandro Sisniega; John Yorkston; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Phys Med Biol       Date:  2016-10-03       Impact factor: 3.609

10.  Experimental realization of fluence field modulated CT using digital beam attenuation.

Authors:  T P Szczykutowicz; C A Mistretta
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.