Literature DB >> 22872419

Investigation of optimum anti-scatter grid selection for digital radiography: physical imaging properties and detectability of low-contrast signals.

Nobukazu Tanaka1, Kentaro Naka, Aya Saito, Junji Morishita, Fukai Toyofuku, Masafumi Ohki, Yoshiharu Higashida.   

Abstract

Our aim in this study was to evaluate the effect of the grid variations on the imaging performance for a computed radiographic system under identical exposure condition. Digital radiographies using a 20-cm Lucite phantom were performed without grid and with grid ratios of 5:1, 8:1, 10:1, 12:1, and 14:1. The scatter fraction, the incident dose to the image receptor, the Wiener spectrum (WS), and the noise-equivalent quanta (NEQ) were measured. Visibility of low-contrast signals was evaluated using a contrast-detail phantom. The scatter fractions decreased considerably with an increase in the grid ratio. On the other hand, the WSs were increased (the noise property deteriorated) as the grid ratio increased due to a decreased incident dose to the image receptor under the identical exposure condition. The NEQs were improved as the grid ratio increased. The high grid ratios provided higher low-contrast detectability compared to the low grid ratios. Our results indicated that the removal of scattered radiation was very effective in improvement of the NEQ in the digital system under the identical exposure condition.

Mesh:

Year:  2012        PMID: 22872419     DOI: 10.1007/s12194-012-0169-y

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  30 in total

1.  Performance of a flat-panel detector in detecting artificial bone lesions: comparison with conventional screen-film and storage-phosphor radiography.

Authors:  Karl Ludwig; Horst Lenzen; Karl-Friedrich Kamm; Thomas M Link; Stefan Diederich; Dag Wormanns; Walter Heindel
Journal:  Radiology       Date:  2002-02       Impact factor: 11.105

2.  Performance of a flat-panel detector in the detection of artificial erosive changes: comparison with conventional screen-film and storage-phosphor radiography.

Authors:  Karl Ludwig; Andreas Henschel; Thomas M Bernhardt; Horst Lenzen; Dag Wormanns; Stefan Diederich; Walter Heindel
Journal:  Eur Radiol       Date:  2002-11-29       Impact factor: 5.315

3.  [Detective quantum efficiency (DQE) and noise-equivalent number of quanta (NEQ)].

Authors:  Yoshie Kodera
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2010-08-20

4.  Detection of subtle microcalcifications: comparison of computed radiography and screen-film mammography.

Authors:  Y Higashida; N Moribe; K Morita; N Katsuda; M Hatemura; T Takada; M Takahashi; J Yamashita
Journal:  Radiology       Date:  1992-05       Impact factor: 11.105

5.  Comparison of imaging properties of a computed radiography system and screen-film systems.

Authors:  S Sanada; K Doi; X W Xu; F F Yin; M L Giger; H MacMahon
Journal:  Med Phys       Date:  1991 May-Jun       Impact factor: 4.071

6.  Computed radiography utilizing laser-stimulated luminescence: detectability of simulated low-contrast radiographic objects.

Authors:  Y Higashida; N Moribe; Y Hirata; K Morita; S Doudanuki; Y Sonoda; N Katsuda; Y Hiai; W Misumi; M Matsumoto
Journal:  Comput Med Imaging Graph       Date:  1988 May-Jun       Impact factor: 4.790

7.  Physical and clinical evaluation of new high-strip-density radiographic grids.

Authors:  K Doi; P H Frank; H P Chan; C J Vyborny; S Makino; N Iida; M Carlin
Journal:  Radiology       Date:  1983-05       Impact factor: 11.105

8.  Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography.

Authors:  R Aufrichtig
Journal:  Med Phys       Date:  1999-07       Impact factor: 4.071

9.  Grid and slot scan scatter reduction in mammography: comparison by using Monte Carlo techniques.

Authors:  John M Boone; J Anthony Seibert; Cha-Mei Tang; Steve M Lane
Journal:  Radiology       Date:  2002-02       Impact factor: 11.105

10.  Clinical evaluation of a new stationary high strip density antiscatter grid in comparison with a conventional moving grid: influence on image quality and patient radiation dose.

Authors:  G R Wamser; H Aichinger; W Maier; K Bohndorf
Journal:  Eur Radiol       Date:  2001       Impact factor: 5.315

View more
  2 in total

1.  A new stationary gridline artifact suppression method based on the 2D discrete wavelet transform.

Authors:  Hui Tang; Dan Tong; Xu Dong Bao; Jean-Louis Dillenseger
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

2.  Investigating the use of an antiscatter grid in chest radiography for average adults with a computed radiography imaging system.

Authors:  C S Moore; T J Wood; G Avery; S Balcam; L Needler; A Smith; J R Saunderson; A W Beavis
Journal:  Br J Radiol       Date:  2015-01-09       Impact factor: 3.039

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.