A new stationary gridline artifact suppression method based on the 2D discrete wavelet transform.

Hui Tang1, Dan Tong2, Xu Dong Bao2, Jean-Louis Dillenseger3.   

Abstract

PURPOSE: In digital x-ray radiography, an antiscatter grid is inserted between the patient and the image receptor to reduce scattered radiation. If the antiscatter grid is used in a stationary way, gridline artifacts will appear in the final image. In most of the gridline removal image processing methods, the useful information with spatial frequencies close to that of the gridline is usually lost or degraded. In this study, a new stationary gridline suppression method is designed to preserve more of the useful information.
METHODS: The method is as follows. The input image is first recursively decomposed into several smaller subimages using a multiscale 2D discrete wavelet transform. The decomposition process stops when the gridline signal is found to be greater than a threshold in one or several of these subimages using a gridline detection module. An automatic Gaussian band-stop filter is then applied to the detected subimages to remove the gridline signal. Finally, the restored image is achieved using the corresponding 2D inverse discrete wavelet transform.
RESULTS: The processed images show that the proposed method can remove the gridline signal efficiently while maintaining the image details. The spectra of a 1D Fourier transform of the processed images demonstrate that, compared with some existing gridline removal methods, the proposed method has better information preservation after the removal of the gridline artifacts. Additionally, the performance speed is relatively high.
CONCLUSIONS: The experimental results demonstrate the efficiency of the proposed method. Compared with some existing gridline removal methods, the proposed method can preserve more information within an acceptable execution time.

Entities:  

Mesh:

Year:  2015        PMID: 25832061      PMCID: PMC5352826          DOI: 10.1118/1.4914861

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  14 in total

1.  The value of scatter removal by a grid in full field digital mammography.

Authors:  Wouter J H Veldkamp; Martin A O Thijssen; Nico Karssemeijer
Journal:  Med Phys       Date:  2003-07       Impact factor: 4.071

2.  A study of grid artifacts formation and elimination in computed radiographic images.

Authors:  Chih-Yang Lin; Wen-Jeng Lee; Shyh-Jye Chen; Ching-Hwa Tsai; Jei-Han Lee; Chia-Hung Chang; Yu-Tai Ching
Journal:  J Digit Imaging       Date:  2006-12       Impact factor: 4.056

3.  A novel technique to suppress grid line artifacts.

Authors:  David M Gauntt; Gary T Barnes
Journal:  Med Phys       Date:  2006-06       Impact factor: 4.071

4.  Reduction of a grid moiré pattern by integrating a carbon-interspaced high precision x-ray grid with a digital radiographic detector.

Authors:  Jai-Woong Yoon; Young-Guk Park; Chun-Joo Park; Do-Il Kim; Jin-Ho Lee; Nag-Kun Chung; Bo-Young Choe; Tae-Suk Suh; Hyoung-Koo Lee
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

5.  Physical evaluation of prototype high-performance anti-scatter grids: potential for improved digital radiographic image quality.

Authors:  Kenneth A Fetterly; Beth A Schueler
Journal:  Phys Med Biol       Date:  2008-12-19       Impact factor: 3.609

6.  Comparative study between mobile computed radiography and mobile flat-panel radiography for bedside chest radiography: impact of an antiscatter grid on the visibility of selected diagnostically relevant structures.

Authors:  Thomas Lehnert; Nagy N N Naguib; Sebastian Wutzler; Ralf W Bauer; Josef Matthias Kerl; Thorsten Burkhard; Boris Schulz; Maya Christina Larson; Hanns Ackermann; Thomas J Vogl; Joern O Balzer
Journal:  Invest Radiol       Date:  2014-01       Impact factor: 6.016

7.  Artifact suppressed dictionary learning for low-dose CT image processing.

Authors:  Yang Chen; Luyao Shi; Qianjing Feng; Jian Yang; Huazhong Shu; Limin Luo; Jean-Louis Coatrieux; Wufan Chen
Journal:  IEEE Trans Med Imaging       Date:  2014-07-10       Impact factor: 10.048

8.  Effectiveness of antiscatter grids in digital radiography. A phantom study.

Authors:  C C Shaw; T Wang; D Gur
Journal:  Invest Radiol       Date:  1994-06       Impact factor: 6.016

9.  Tantalum air-interspace crossed grid: design and performance characteristics.

Authors:  J A Sorenson; L T Niklason; S C Jacobsen; D F Knutti; T C Johnson
Journal:  Radiology       Date:  1982-11       Impact factor: 11.105

10.  Grid removal and impact on population dose in full-field digital mammography.

Authors:  Gisella Gennaro; Luc Katz; Henri Souchay; Remy Klausz; Claudio Alberelli; Cosimo di Maggio
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

View more
  2 in total

1.  Transmission characteristics of a two dimensional antiscatter grid prototype for CBCT.

Authors:  Cem Altunbas; Brian Kavanagh; Timur Alexeev; Moyed Miften
Journal:  Med Phys       Date:  2017-06-16       Impact factor: 4.071

2.  Patch Based Grid Artifact Suppressing in Digital Mammography.

Authors:  Qingqing Ling; Shuyu Wu; Xiaoman Duan; Genggeng Qin; Jianhui Ma; Chaomin Chen; Hongliang Qi; Linghong Zhou; Yuan Xu
Journal:  Biomed Res Int       Date:  2018-08-12       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.