Literature DB >> 22797602

Least median of squares filtering of locally optimal point matches for compressible flow image registration.

Edward Castillo1, Richard Castillo, Benjamin White, Javier Rojo, Thomas Guerrero.   

Abstract

Compressible flow based image registration operates under the assumption that the mass of the imaged material is conserved from one image to the next. Depending on how the mass conservation assumption is modeled, the performance of existing compressible flow methods is limited by factors such as image quality, noise, large magnitude voxel displacements, and computational requirements. The Least Median of Squares Filtered Compressible Flow (LFC) method introduced here is based on a localized, nonlinear least squares, compressible flow model that describes the displacement of a single voxel that lends itself to a simple grid search (block matching) optimization strategy. Spatially inaccurate grid search point matches, corresponding to erroneous local minimizers of the nonlinear compressible flow model, are removed by a novel filtering approach based on least median of squares fitting and the forward search outlier detection method. The spatial accuracy of the method is measured using ten thoracic CT image sets and large samples of expert determined landmarks (available at www.dir-lab.com). The LFC method produces an average error within the intra-observer error on eight of the ten cases, indicating that the method is capable of achieving a high spatial accuracy for thoracic CT registration.

Entities:  

Mesh:

Year:  2012        PMID: 22797602      PMCID: PMC3448271          DOI: 10.1088/0031-9155/57/15/4827

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

1.  Ventilation from four-dimensional computed tomography: density versus Jacobian methods.

Authors:  Richard Castillo; Edward Castillo; Josue Martinez; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2010-07-30       Impact factor: 3.609

2.  Dynamic ventilation imaging from four-dimensional computed tomography.

Authors:  Thomas Guerrero; Kevin Sanders; Edward Castillo; Yin Zhang; Luc Bidaut; Tinsu Pan; Ritsuko Komaki
Journal:  Phys Med Biol       Date:  2006-01-25       Impact factor: 3.609

3.  Computation of 3-D velocity fields from 3-D cine CT images of a human heart.

Authors:  S M Song; R M Leahy
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

4.  A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets.

Authors:  Richard Castillo; Edward Castillo; Rudy Guerra; Valen E Johnson; Travis McPhail; Amit K Garg; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

5.  High performance computing for deformable image registration: towards a new paradigm in adaptive radiotherapy.

Authors:  Sanjiv S Samant; Junyi Xia; Pinar Muyan-Ozcelik; John D Owens
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

6.  The role of image registration in brain mapping.

Authors:  A W Toga; P M Thompson
Journal:  Image Vis Comput       Date:  2001-01-01       Impact factor: 2.818

Review 7.  GPU computing for systems biology.

Authors:  Lorenzo Dematté; Davide Prandi
Journal:  Brief Bioinform       Date:  2010-03-07       Impact factor: 11.622

Review 8.  GPU computing in medical physics: a review.

Authors:  Guillem Pratx; Lei Xing
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

9.  Four-dimensional deformable image registration using trajectory modeling.

Authors:  Edward Castillo; Richard Castillo; Josue Martinez; Maithili Shenoy; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

10.  Implementation and evaluation of various demons deformable image registration algorithms on a GPU.

Authors:  Xuejun Gu; Hubert Pan; Yun Liang; Richard Castillo; Deshan Yang; Dongju Choi; Edward Castillo; Amitava Majumdar; Thomas Guerrero; Steve B Jiang
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

View more
  18 in total

1.  Quadratic penalty method for intensity-based deformable image registration and 4DCT lung motion recovery.

Authors:  Edward Castillo
Journal:  Med Phys       Date:  2019-03-14       Impact factor: 4.071

2.  Deformable image registration for temporal subtraction of chest radiographs.

Authors:  Min Li; Edward Castillo; Hong-Yan Luo; Xiao-Lin Zheng; Richard Castillo; Dmitriy Meshkov; Thomas Guerrero
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-07       Impact factor: 2.924

3.  Regional Lung Function Profiles of Stage I and III Lung Cancer Patients: An Evaluation for Functional Avoidance Radiation Therapy.

Authors:  Yevgeniy Vinogradskiy; Leah Schubert; Quentin Diot; Timothy Waxweiller; Phillip Koo; Richard Castillo; Edward Castillo; Thomas Guerrero; Chad Rusthoven; Laurie Gaspar; Brian Kavanagh; Moyed Miften
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-07-15       Impact factor: 7.038

4.  Automated identification and reduction of artifacts in cine four-dimensional computed tomography (4DCT) images using respiratory motion model.

Authors:  Min Li; Sarah Joy Castillo; Richard Castillo; Edward Castillo; Thomas Guerrero; Liang Xiao; Xiaolin Zheng
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-14       Impact factor: 2.924

5.  GPU-accelerated Block Matching Algorithm for Deformable Registration of Lung CT Images.

Authors:  Min Li; Zhikang Xiang; Liang Xiao; Edward Castillo; Richard Castillo; Thomas Guerrero
Journal:  Proc IEEE Int Conf Prog Inform Comput       Date:  2016-06-13

6.  Clinical validation of 4-dimensional computed tomography ventilation with pulmonary function test data.

Authors:  Douglas Brennan; Leah Schubert; Quentin Diot; Richard Castillo; Edward Castillo; Thomas Guerrero; Mary K Martel; Derek Linderman; Laurie E Gaspar; Moyed Miften; Brian D Kavanagh; Yevgeniy Vinogradskiy
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-03-25       Impact factor: 7.038

7.  Computing global minimizers to a constrained B-spline image registration problem from optimal l1 perturbations to block match data.

Authors:  Edward Castillo; Richard Castillo; David Fuentes; Thomas Guerrero
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

8.  Pre-Radiation Therapy Fluorine 18 Fluorodeoxyglucose PET Helps Identify Patients with Esophageal Cancer at High Risk for Radiation Pneumonitis.

Authors:  Richard Castillo; Ngoc Pham; Edward Castillo; Samantha Aso-Gonzalez; Sobiya Ansari; Brian Hobbs; Diana Palacio; Heath Skinner; Thomas M Guerrero
Journal:  Radiology       Date:  2015-01-13       Impact factor: 11.105

9.  Interim Analysis of a Two-Institution, Prospective Clinical Trial of 4DCT-Ventilation-based Functional Avoidance Radiation Therapy.

Authors:  Yevgeniy Vinogradskiy; Chad G Rusthoven; Leah Schubert; Bernard Jones; Austin Faught; Richard Castillo; Edward Castillo; Laurie E Gaspar; Jennifer Kwak; Timothy Waxweiler; Michele Dougherty; Dexiang Gao; Craig Stevens; Moyed Miften; Brian Kavanagh; Thomas Guerrero; Inga Grills
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-10-18       Impact factor: 7.038

10.  Comparison of 4-dimensional computed tomography ventilation with nuclear medicine ventilation-perfusion imaging: a clinical validation study.

Authors:  Yevgeniy Vinogradskiy; Phillip J Koo; Richard Castillo; Edward Castillo; Thomas Guerrero; Laurie E Gaspar; Moyed Miften; Brian D Kavanagh
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-05-01       Impact factor: 7.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.