Literature DB >> 16467578

Dynamic ventilation imaging from four-dimensional computed tomography.

Thomas Guerrero1, Kevin Sanders, Edward Castillo, Yin Zhang, Luc Bidaut, Tinsu Pan, Ritsuko Komaki.   

Abstract

A novel method for dynamic ventilation imaging of the full respiratory cycle from four-dimensional computed tomography (4D CT) acquired without added contrast is presented. Three cases with 4D CT images obtained with respiratory gated acquisition for radiotherapy treatment planning were selected. Each of the 4D CT data sets was acquired during resting tidal breathing. A deformable image registration algorithm mapped each (voxel) corresponding tissue element across the 4D CT data set. From local average CT values, the change in fraction of air per voxel (i.e. local ventilation) was calculated. A 4D ventilation image set was calculated using pairs formed with the maximum expiration image volume, first the exhalation then the inhalation phases representing a complete breath cycle. A preliminary validation using manually determined lung volumes was performed. The calculated total ventilation was compared to the change in contoured lung volumes between the CT pairs (measured volume). A linear regression resulted in a slope of 1.01 and a correlation coefficient of 0.984 for the ventilation images. The spatial distribution of ventilation was found to be case specific and a 30% difference in mass-specific ventilation between the lower and upper lung halves was found. These images may be useful in radiotherapy planning.

Mesh:

Year:  2006        PMID: 16467578     DOI: 10.1088/0031-9155/51/4/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  65 in total

1.  A method to evaluate dose errors introduced by dose mapping processes for mass conserving deformations.

Authors:  C Yan; G Hugo; F J Salguero; N Saleh-Sayah; E Weiss; W C Sleeman; J V Siebers
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Assessment of regional non-linear tissue deformation and air volume change of human lungs via image registration.

Authors:  Nariman Jahani; Youbing Yin; Eric A Hoffman; Ching-Long Lin
Journal:  J Biomech       Date:  2014-03-13       Impact factor: 2.712

Review 3.  Functional imaging: CT and MRI.

Authors:  Edwin J R van Beek; Eric A Hoffman
Journal:  Clin Chest Med       Date:  2008-03       Impact factor: 2.878

4.  4D CT lung ventilation images are affected by the 4D CT sorting method.

Authors:  Tokihiro Yamamoto; Sven Kabus; Cristian Lorenz; Eric Johnston; Peter G Maxim; Maximilian Diehn; Neville Eclov; Cristian Barquero; Billy W Loo; Paul J Keall
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

5.  Comparison of image registration based measures of regional lung ventilation from dynamic spiral CT with Xe-CT.

Authors:  Kai Ding; Kunlin Cao; Matthew K Fuld; Kaifang Du; Gary E Christensen; Eric A Hoffman; Joseph M Reinhardt
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

6.  Regional Lung Function Profiles of Stage I and III Lung Cancer Patients: An Evaluation for Functional Avoidance Radiation Therapy.

Authors:  Yevgeniy Vinogradskiy; Leah Schubert; Quentin Diot; Timothy Waxweiller; Phillip Koo; Richard Castillo; Edward Castillo; Thomas Guerrero; Chad Rusthoven; Laurie Gaspar; Brian Kavanagh; Moyed Miften
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-07-15       Impact factor: 7.038

7.  Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements.

Authors:  Kaifang Du; Joseph M Reinhardt; Gary E Christensen; Kai Ding; John E Bayouth
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

8.  An initial investigation of hyperpolarized gas tagging magnetic resonance imaging in evaluating deformable image registration-based lung ventilation.

Authors:  Taoran Cui; G Wilson Miller; John P Mugler; Gordon D Cates; Jaime F Mata; Eduard E de Lange; Qijie Huang; Talissa A Altes; Fang-Fang Yin; Jing Cai
Journal:  Med Phys       Date:  2018-10-23       Impact factor: 4.071

9.  Four-dimensional deformable image registration using trajectory modeling.

Authors:  Edward Castillo; Richard Castillo; Josue Martinez; Maithili Shenoy; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

10.  Interim Analysis of a Two-Institution, Prospective Clinical Trial of 4DCT-Ventilation-based Functional Avoidance Radiation Therapy.

Authors:  Yevgeniy Vinogradskiy; Chad G Rusthoven; Leah Schubert; Bernard Jones; Austin Faught; Richard Castillo; Edward Castillo; Laurie E Gaspar; Jennifer Kwak; Timothy Waxweiler; Michele Dougherty; Dexiang Gao; Craig Stevens; Moyed Miften; Brian Kavanagh; Thomas Guerrero; Inga Grills
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-10-18       Impact factor: 7.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.