Literature DB >> 20009196

Four-dimensional deformable image registration using trajectory modeling.

Edward Castillo1, Richard Castillo, Josue Martinez, Maithili Shenoy, Thomas Guerrero.   

Abstract

A four-dimensional deformable image registration (4D DIR) algorithm, referred to as 4D local trajectory modeling (4DLTM), is presented and applied to thoracic 4D computed tomography (4DCT) image sets. The theoretical framework on which this algorithm is built exploits the incremental continuity present in 4DCT component images to calculate a dense set of parameterized voxel trajectories through space as functions of time. The spatial accuracy of the 4DLTM algorithm is compared with an alternative registration approach in which component phase to phase (CPP) DIR is utilized to determine the full displacement between maximum inhale and exhale images. A publically available DIR reference database (http://www.dir-lab.com) is utilized for the spatial accuracy assessment. The database consists of ten 4DCT image sets and corresponding manually identified landmark points between the maximum phases. A subset of points are propagated through the expiratory 4DCT component images. Cubic polynomials were found to provide sufficient flexibility and spatial accuracy for describing the point trajectories through the expiratory phases. The resulting average spatial error between the maximum phases was 1.25 mm for the 4DLTM and 1.44 mm for the CPP. The 4DLTM method captures the long-range motion between 4DCT extremes with high spatial accuracy.

Entities:  

Mesh:

Year:  2010        PMID: 20009196      PMCID: PMC3696886          DOI: 10.1088/0031-9155/55/1/018

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  40 in total

Review 1.  A survey of medical image registration.

Authors:  J B Maintz; M A Viergever
Journal:  Med Image Anal       Date:  1998-03       Impact factor: 8.545

2.  Four-dimensional processing of deformable cardiac PET data.

Authors:  Gregory J Klein; Ronald H Huesman
Journal:  Med Image Anal       Date:  2002-03       Impact factor: 8.545

3.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT.

Authors:  Tinsu Pan; Ting-Yim Lee; Eike Rietzel; George T Y Chen
Journal:  Med Phys       Date:  2004-02       Impact factor: 4.071

4.  Deformable registration of 4D computed tomography data.

Authors:  Eike Rietzel; George T Y Chen
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

5.  Evaluation of an automated deformable image matching method for quantifying lung motion in respiration-correlated CT images.

Authors:  A Pevsner; B Davis; S Joshi; A Hertanto; J Mechalakos; E Yorke; K Rosenzweig; S Nehmeh; Y E Erdi; J L Humm; S Larson; C C Ling; G S Mageras
Journal:  Med Phys       Date:  2006-02       Impact factor: 4.071

6.  Real-time 3D computed tomographic reconstruction using commodity graphics hardware.

Authors:  Fang Xu; Klaus Mueller
Journal:  Phys Med Biol       Date:  2007-05-17       Impact factor: 3.609

7.  Registration-based estimates of local lung tissue expansion compared to xenon CT measures of specific ventilation.

Authors:  Joseph M Reinhardt; Kai Ding; Kunlin Cao; Gary E Christensen; Eric A Hoffman; Shalmali V Bodas
Journal:  Med Image Anal       Date:  2008-04-12       Impact factor: 8.545

8.  Intrathoracic tumour motion estimation from CT imaging using the 3D optical flow method.

Authors:  Thomas Guerrero; Geoffrey Zhang; Tzung-Chi Huang; Kang-Ping Lin
Journal:  Phys Med Biol       Date:  2004-09-07       Impact factor: 3.609

9.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

Authors:  Yvette Seppenwoolde; Hiroki Shirato; Kei Kitamura; Shinichi Shimizu; Marcel van Herk; Joos V Lebesque; Kazuo Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-07-15       Impact factor: 7.038

10.  4D-CT lung motion estimation with deformable registration: quantification of motion nonlinearity and hysteresis.

Authors:  Vlad Boldea; Gregory C Sharp; Steve B Jiang; David Sarrut
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

View more
  47 in total

1.  Estimation of smooth growth trajectories with controlled acceleration from time series shape data.

Authors:  James Fishbaugh; Stanley Durrleman; Guido Gerig
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

2.  A hybrid biomechanical intensity based deformable image registration of lung 4DCT.

Authors:  Navid Samavati; Michael Velec; Kristy Brock
Journal:  Phys Med Biol       Date:  2015-04-01       Impact factor: 3.609

3.  Quadratic penalty method for intensity-based deformable image registration and 4DCT lung motion recovery.

Authors:  Edward Castillo
Journal:  Med Phys       Date:  2019-03-14       Impact factor: 4.071

4.  Deformable image registration for temporal subtraction of chest radiographs.

Authors:  Min Li; Edward Castillo; Hong-Yan Luo; Xiao-Lin Zheng; Richard Castillo; Dmitriy Meshkov; Thomas Guerrero
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-07       Impact factor: 2.924

5.  A fast deformable registration method for 4D lung CT in hybrid framework.

Authors:  Wei Xia; Xin Gao
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-11-22       Impact factor: 2.924

6.  Automated identification and reduction of artifacts in cine four-dimensional computed tomography (4DCT) images using respiratory motion model.

Authors:  Min Li; Sarah Joy Castillo; Richard Castillo; Edward Castillo; Thomas Guerrero; Liang Xiao; Xiaolin Zheng
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-14       Impact factor: 2.924

7.  Functional-guided radiotherapy using knowledge-based planning.

Authors:  Austin M Faught; Lindsey Olsen; Leah Schubert; Chad Rusthoven; Edward Castillo; Richard Castillo; Jingjing Zhang; Thomas Guerrero; Moyed Miften; Yevgeniy Vinogradskiy
Journal:  Radiother Oncol       Date:  2018-04-05       Impact factor: 6.280

8.  Error estimation of deformable image registration of pulmonary CT scans using convolutional neural networks.

Authors:  Koen A J Eppenhof; Josien P W Pluim
Journal:  J Med Imaging (Bellingham)       Date:  2018-05-10

9.  Iterative inversion of deformation vector fields with feedback control.

Authors:  Abhishek Dubey; Alexandros-Stavros Iliopoulos; Xiaobai Sun; Fang-Fang Yin; Lei Ren
Journal:  Med Phys       Date:  2018-06-10       Impact factor: 4.071

10.  An initial investigation of hyperpolarized gas tagging magnetic resonance imaging in evaluating deformable image registration-based lung ventilation.

Authors:  Taoran Cui; G Wilson Miller; John P Mugler; Gordon D Cates; Jaime F Mata; Eduard E de Lange; Qijie Huang; Talissa A Altes; Fang-Fang Yin; Jing Cai
Journal:  Med Phys       Date:  2018-10-23       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.