Hematocrit compensation in electrochemical blood glucose monitoring systems.

Maria Teodorczyk1, Marco Cardosi, Steven Setford.   

Abstract

BACKGROUND: Hematocrit (Hct) is a common interferent in test strips used by diabetes patients to self-monitor blood glucose (BG), resulting in measurement bias. Described is an electrochemical BG monitoring system (OneTouch(®) Verio™) that uses a cofacial sensor design, soluble enzyme chemistry, and multiphasic waveform to effectively correct for patient Hct, delivering an accurate reading for whole BG.
METHODS: The test strip comprises thin-film gold and palladium electrodes arranged cofacially and spatially separated with a thin spacer. Soluble glucose-sensing reagents are located on the lower palladium electrode and are hydrated on sample application. Blood glucose is oxidized by flavoprotein glucose dehydrogenase, with electron transfer via (reduced) potassium ferrocyanide mediator at the palladium electrode. Hematocrit levels are estimated by measuring oxidation of mediator diffusion to the upper gold electrode during the first portion of the assay. The Hct-corrected glucose levels are determined by an on-meter algorithm.
RESULTS: In performance testing of blood samples at five glucose levels (30-560 mg/dl) and five Hct levels (19-61%), using 12 test meters and 3 test strip lots, 100% of results (N = 2700) met International Organization for Standardization accuracy criteria (within ± 15 mg/dl and ± 20% of reference results at glucose levels of <75 and ≥75 mg/dl, respectively). Furthermore, 99.9% (2698 of 2700) of results were within ±12 mg/dl and ± 15% of reference values at glucose levels <80 and ≥80 mg/dl, respectively.
CONCLUSIONS: The technology used in this system provides accurate BG measurements that are insensitive to Hct levels across the range 20-60%.
© 2012 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22768896      PMCID: PMC3440048          DOI: 10.1177/193229681200600320

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  23 in total

1.  Effects of different hematocrit levels on glucose measurements with handheld meters for point-of-care testing.

Authors:  Z Tang; J H Lee; R F Louie; G J Kost
Journal:  Arch Pathol Lab Med       Date:  2000-08       Impact factor: 5.534

2.  Self-monitoring of blood glucose levels and glycemic control: the Northern California Kaiser Permanente Diabetes registry.

Authors:  A J Karter; L M Ackerson; J A Darbinian; R B D'Agostino; A Ferrara; J Liu; J V Selby
Journal:  Am J Med       Date:  2001-07       Impact factor: 4.965

Review 3.  Quality of glucose measurement with blood glucose meters at the point-of-care: relevance of interfering factors.

Authors:  Lutz Heinemann
Journal:  Diabetes Technol Ther       Date:  2010-09-30       Impact factor: 6.118

4.  Effect of hematocrit concentration on blood glucose value determined on Glucometer II.

Authors:  P B Barreau; J E Buttery
Journal:  Diabetes Care       Date:  1988-02       Impact factor: 19.112

5.  Retinopathy and nephropathy in patients with type 1 diabetes four years after a trial of intensive therapy.

Authors:  John M Lachin; Saul Genuth; Patricia Cleary; Matthew D Davis; David M Nathan
Journal:  N Engl J Med       Date:  2000-02-10       Impact factor: 91.245

6.  Patient acuity exacerbates discrepancy between whole blood and plasma methods through error in molality to molarity conversion: "Mind the gap!".

Authors:  Martha E Lyon; Andrew W Lyon
Journal:  Clin Biochem       Date:  2011-01-19       Impact factor: 3.281

7.  Effect of high altitude on blood glucose meter performance.

Authors:  Kenneth S Fink; Dale B Christensen; Allan Ellsworth
Journal:  Diabetes Technol Ther       Date:  2002       Impact factor: 6.118

8.  Death, hospitalization, and economic associations among incident hemodialysis patients with hematocrit values of 36 to 39%.

Authors:  Allan J Collins; Suying Li; Wendy St Peter; Jim Ebben; Tricia Roberts; Jennie Z Ma; Willard Manning
Journal:  J Am Soc Nephrol       Date:  2001-11       Impact factor: 10.121

9.  Dynamic electrochemistry corrects for hematocrit interference on blood glucose determinations with patient self-measurement devices.

Authors:  Petra B Musholt; Christina Schipper; Nicole Thomé; Sanja Ramljak; Marc Schmidt; Thomas Forst; Andreas Pfützner
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

10.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus.

Authors:  D M Nathan; S Genuth; J Lachin; P Cleary; O Crofford; M Davis; L Rand; C Siebert
Journal:  N Engl J Med       Date:  1993-09-30       Impact factor: 91.245

View more
  8 in total

1.  Analysis of an electrochemical blood glucose monitoring system with hematocrit compensation: improved accuracy by design.

Authors:  Martha E Lyon; Andrew W Lyon
Journal:  J Diabetes Sci Technol       Date:  2012-05-01

2.  Seven-Year Surveillance of the Clinical Performance of a Blood Glucose Test Strip Product.

Authors:  Steven Setford; Mike Grady; Stuart Phillips; Lesley Miller; Stephen Mackintosh; Hilary Cameron; Krisna Corrigall
Journal:  J Diabetes Sci Technol       Date:  2017-04-13

3.  Clinical evaluation of a novel on-strip calibration method for blood glucose measurement.

Authors:  Michael Noble; John Rippeth; David Edington; Gerry Rayman; Sarah Brandon-Jones; Zoe Hollowood; Simon Kew
Journal:  J Diabetes Sci Technol       Date:  2014-05-12

4.  Meeting the New FDA Standard for Accuracy of Self-Monitoring Blood Glucose Test Systems Intended for Home Use by Lay Users.

Authors:  Laurence B Katz; Lorna Stewart; Danielle King; Hilary Cameron
Journal:  J Diabetes Sci Technol       Date:  2020-02-14

5.  Clinical Study of a High Accuracy Green Design Blood Glucose Monitor Using an Innovative Optical Transmission Absorbance System.

Authors:  Takeyuki Moriuchi; Yuto Otaki; Hiroya Satou; Fumihiko Chai; Yuma Hayashida; Ryokei Aikawa; Takayuki Sugiyama; Koji Sode
Journal:  J Diabetes Sci Technol       Date:  2021-12-10

6.  Patient Satisfaction With a New, High Accuracy Blood Glucose Meter That Provides Personalized Guidance, Insight, and Encouragement.

Authors:  Laurence B Katz; Lorna Stewart; Brian Guthrie; Hilary Cameron
Journal:  J Diabetes Sci Technol       Date:  2019-08-02

7.  Evaluation of Hematocrit Influence on Self-Monitoring of Blood Glucose Based on ISO 15197:2013: Comparison of a Novel System With Five Systems With Different Hematocrit Ranges.

Authors:  Andrew Hattemer; Sami Wardat
Journal:  J Diabetes Sci Technol       Date:  2018-01-29

8.  Performance of a new meter designed for assisted monitoring of blood glucose and point-of-care testing.

Authors:  Sandra Macrury; Aparna Srinivasan; John J Mahoney
Journal:  J Diabetes Sci Technol       Date:  2013-03-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.