MRI-based nonrigid motion correction in simultaneous PET/MRI.

Se Young Chun1, Timothy G Reese, Jinsong Ouyang, Bastien Guerin, Ciprian Catana, Xuping Zhu, Nathaniel M Alpert, Georges El Fakhri.   

Abstract

UNLABELLED: Respiratory and cardiac motion is the most serious limitation to whole-body PET, resulting in spatial resolution close to 1 cm. Furthermore, motion-induced inconsistencies in the attenuation measurements often lead to significant artifacts in the reconstructed images. Gating can remove motion artifacts at the cost of increased noise. This paper presents an approach to respiratory motion correction using simultaneous PET/MRI to demonstrate initial results in phantoms, rabbits, and nonhuman primates and discusses the prospects for clinical application.
METHODS: Studies with a deformable phantom, a free-breathing primate, and rabbits implanted with radioactive beads were performed with simultaneous PET/MRI. Motion fields were estimated from concurrently acquired tagged MR images using 2 B-spline nonrigid image registration methods and incorporated into a PET list-mode ordered-subsets expectation maximization algorithm. Using the measured motion fields to transform both the emission data and the attenuation data, we could use all the coincidence data to reconstruct any phase of the respiratory cycle. We compared the resulting SNR and the channelized Hotelling observer (CHO) detection signal-to-noise ratio (SNR) in the motion-corrected reconstruction with the results obtained from standard gating and uncorrected studies.
RESULTS: Motion correction virtually eliminated motion blur without reducing SNR, yielding images with SNR comparable to those obtained by gating with 5-8 times longer acquisitions in all studies. The CHO study in dynamic phantoms demonstrated a significant improvement (166%-276%) in lesion detection SNR with MRI-based motion correction as compared with gating (P < 0.001). This improvement was 43%-92% for large motion compared with lesion detection without motion correction (P < 0.001). CHO SNR in the rabbit studies confirmed these results.
CONCLUSION: Tagged MRI motion correction in simultaneous PET/MRI significantly improves lesion detection compared with respiratory gating and no motion correction while reducing radiation dose. In vivo primate and rabbit studies confirmed the improvement in PET image quality and provide the rationale for evaluation in simultaneous whole-body PET/MRI clinical studies.

Entities:  

Mesh:

Year:  2012        PMID: 22743250      PMCID: PMC4077320          DOI: 10.2967/jnumed.111.092353

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  32 in total

1.  Simultaneous PET-MR acquisition and MR-derived motion fields for correction of non-rigid motion in PET.

Authors:  Charalampos Tsoumpas; Jane E Mackewn; Philip Halsted; Andrew P King; Christian Buerger; John J Totman; Tobias Schaeffter; Paul K Marsden
Journal:  Ann Nucl Med       Date:  2010-09-15       Impact factor: 2.668

2.  Joint reconstruction of image and motion in gated positron emission tomography.

Authors:  Moritz Blume; Axel Martinez-Möller; Andreas Keil; Nassir Navab; Magdalena Rafecas
Journal:  IEEE Trans Med Imaging       Date:  2010-06-17       Impact factor: 10.048

3.  Model-based image reconstruction for four-dimensional PET.

Authors:  Tianfang Li; Brian Thorndyke; Eduard Schreibmann; Yong Yang; Lei Xing
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

Review 4.  Combined PET/MRI: a new dimension in whole-body oncology imaging?

Authors:  Gerald Antoch; Andreas Bockisch
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

5.  Regularized B-spline deformable registration for respiratory motion correction in PET images.

Authors:  Wenjia Bai; Michael Brady
Journal:  Phys Med Biol       Date:  2009-04-08       Impact factor: 3.609

6.  Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype.

Authors:  Ciprian Catana; Andre van der Kouwe; Thomas Benner; Christian J Michel; Michael Hamm; Matthias Fenchel; Bruce Fischl; Bruce Rosen; Matthias Schmand; A Gregory Sorensen
Journal:  J Nucl Med       Date:  2010-09       Impact factor: 10.057

7.  A simple regularizer for B-spline nonrigid image registration that encourages local invertibility.

Authors:  Se Young Chun; Jeffrey A Fessler
Journal:  IEEE J Sel Top Signal Process       Date:  2009-02-01       Impact factor: 6.856

8.  Dual cardiac-respiratory gated PET: implementation and results from a feasibility study.

Authors:  Axel Martinez-Möller; Darko Zikic; René M Botnar; Ralph A Bundschuh; William Howe; Sibylle I Ziegler; Nassir Navab; Markus Schwaiger; Stephan G Nekolla
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02-21       Impact factor: 9.236

9.  Cine CT for attenuation correction in cardiac PET/CT.

Authors:  Adam M Alessio; Steve Kohlmyer; Kelley Branch; Grace Chen; James Caldwell; Paul Kinahan
Journal:  J Nucl Med       Date:  2007-05       Impact factor: 10.057

Review 10.  Multimodality imaging: an update on PET/CT technology.

Authors:  Osama Mawlawi; David W Townsend
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

View more
  46 in total

Review 1.  Potential Role of PET/MRI for Imaging Metastatic Lymph Nodes in Head and Neck Cancer.

Authors:  Sungheon Gene Kim; Kent Friedman; Sohil Patel; Mari Hagiwara
Journal:  AJR Am J Roentgenol       Date:  2016-05-10       Impact factor: 3.959

2.  Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: phantom and patient studies.

Authors:  Chuan Huang; Yoann Petibon; Jinsong Ouyang; Timothy G Reese; Mark A Ahlman; David A Bluemke; Georges El Fakhri
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

Review 3.  Motion correction options in PET/MRI.

Authors:  Ciprian Catana
Journal:  Semin Nucl Med       Date:  2015-05       Impact factor: 4.446

4.  Imaging moving heart structures with PET.

Authors:  Piotr J Slomka; Tinsu Pan; Guido Germano
Journal:  J Nucl Cardiol       Date:  2015-03-26       Impact factor: 5.952

5.  Advances in imaging instrumentation for nuclear cardiology.

Authors:  Jae Sung Lee; Gil Kovalski; Tali Sharir; Dong Soo Lee
Journal:  J Nucl Cardiol       Date:  2017-07-17       Impact factor: 5.952

6.  A comparison of CT- and MR-based attenuation correction in neurological PET.

Authors:  John C Dickson; Celia O'Meara; Anna Barnes
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-01-15       Impact factor: 9.236

7.  Accurate high-resolution measurements of 3-D tissue dynamics with registration-enhanced displacement encoded MRI.

Authors:  Arnold D Gomez; Samer S Merchant; Edward W Hsu
Journal:  IEEE Trans Med Imaging       Date:  2014-03-14       Impact factor: 10.048

Review 8.  Positron emission tomography-magnetic resonance imaging: technical review.

Authors:  Raymond F Muzic; Frank P DiFilippo
Journal:  Semin Roentgenol       Date:  2014-10-18       Impact factor: 0.800

9.  Towards coronary plaque imaging using simultaneous PET-MR: a simulation study.

Authors:  Y Petibon; G El Fakhri; R Nezafat; N Johnson; T Brady; J Ouyang
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

Review 10.  PET and MR imaging: the odd couple or a match made in heaven?

Authors:  Ciprian Catana; Alexander R Guimaraes; Bruce R Rosen
Journal:  J Nucl Med       Date:  2013-03-14       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.