Literature DB >> 17475969

Cine CT for attenuation correction in cardiac PET/CT.

Adam M Alessio1, Steve Kohlmyer, Kelley Branch, Grace Chen, James Caldwell, Paul Kinahan.   

Abstract

UNLABELLED: In dual-modality PET/CT systems, the CT scan provides the attenuation map for PET attenuation correction. The current clinical practice of obtaining a single helical CT scan provides only a snapshot of the respiratory cycle, whereas PET occurs over multiple respiratory cycles. Misalignment of the attenuation map and emission image because of respiratory motion causes errors in the attenuation correction factors and artifacts in the attenuation-corrected PET image. To rectify this problem, we evaluated the use of cine CT, which acquires multiple low-dose CT images during a respiratory cycle. We evaluated the average and the intensity-maximum image of cine CT for cardiac PET attenuation correction.
METHODS: Cine CT data and cardiac PET data were acquired from a cardiac phantom and from multiple patient studies. The conventional helical CT, cine CT, and PET data of an axially translating phantom were evaluated with and without respiratory motion. For the patient studies, we acquired 2 cine CT studies for each PET acquisition in a rest-stress (13)N-ammonia protocol. Three readers visually evaluated the alignment of 74 attenuation image sets versus the corresponding emission image and determined whether the alignment provided acceptable or unacceptable attenuation-corrected PET images.
RESULTS: In the phantom study, the attenuation correction from helical CT caused a major artifactual defect in the lateral wall on the PET image. The attenuation correction from the average and from the intensity-maximum cine CT images reduced the defect by 20% and 60%, respectively. In the patient studies, 77% of the cases using the average of the cine CT images had acceptable alignment and 88% of the cases using the intensity maximum of the cine CT images had acceptable alignment.
CONCLUSION: Cine CT offers an alternative to helical CT for compensating for respiratory motion in the attenuation correction of cardiac PET studies. Phantom studies suggest that the average and the intensity maximum of the cine CT images can reduce potential respiration-induced misalignment errors in attenuation correction. Patient studies reveal that cine CT provides acceptable alignment in most cases and suggest that the intensity-maximum cine image offers a more robust alternative to the average cine image.

Entities:  

Mesh:

Year:  2007        PMID: 17475969      PMCID: PMC2585486          DOI: 10.2967/jnumed.106.035717

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  21 in total

1.  Imaging of noncalcified coronary plaques using helical CT with retrospective ECG gating.

Authors:  C R Becker; A Knez; B Ohnesorge; U J Schoepf; M F Reiser
Journal:  AJR Am J Roentgenol       Date:  2000-08       Impact factor: 3.959

2.  Respiration-induced attenuation artifact at PET/CT: technical considerations.

Authors:  Gerhard W Goerres; Cyrill Burger; Ehab Kamel; Burkhardt Seifert; Achim H Kaim; Alfred Buck; Tobias C Buehler; Gustav K Von Schulthess
Journal:  Radiology       Date:  2003-03       Impact factor: 11.105

3.  Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology.

Authors:  Thomas Beyer; Gerald Antoch; Todd Blodgett; Lutz F Freudenberg; Tim Akhurst; Stephan Mueller
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-02-12       Impact factor: 9.236

4.  PET myocardial glucose metabolism and perfusion imaging: Part 1-Guidelines for data acquisition and patient preparation.

Authors:  Stephen L Bacharach; Jeroen J Bax; James Case; Dominique Delbeke; Karen A Kurdziel; William H Martin; Randolph E Patterson
Journal:  J Nucl Cardiol       Date:  2003 Sep-Oct       Impact factor: 5.952

Review 5.  X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

Authors:  Paul E Kinahan; Bruce H Hasegawa; Thomas Beyer
Journal:  Semin Nucl Med       Date:  2003-07       Impact factor: 4.446

6.  PET-CT evaluation of 2-deoxy-2-[18F]fluoro-D-glucose myocardial uptake: effect of respiratory motion.

Authors:  Bennett B Chin; Yuji Nakamoto; Dara L Kraitchman; Laura Marshall; Richard Wahl
Journal:  Mol Imaging Biol       Date:  2003 Mar-Apr       Impact factor: 3.488

7.  PET-CT image co-registration in the thorax: influence of respiration.

Authors:  Gerhard W Goerres; Ehab Kamel; Thai-Nia H Heidelberg; Michael R Schwitter; Cyrill Burger; Gustav K von Schulthess
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-03       Impact factor: 9.236

8.  Noninvasive detection of coronary lesions by multislice computed tomography: results of the New Age pilot trial.

Authors:  S Schroeder; A F Kopp; A Baumbach; A Kuettner; C Herdeg; A Rosenberger; H K Selbmann; C D Claussen; M Oberhoff; K R Karsch
Journal:  Catheter Cardiovasc Interv       Date:  2001-07       Impact factor: 2.692

Review 9.  18F-deoxyglucose and the assessment of myocardial viability.

Authors:  Heinrich R Schelbert
Journal:  Semin Nucl Med       Date:  2002-01       Impact factor: 4.446

10.  PET/CT: comparison of quantitative tracer uptake between germanium and CT transmission attenuation-corrected images.

Authors:  Yuji Nakamoto; Medhat Osman; Christian Cohade; Laura T Marshall; Jonathan M Links; Steve Kohlmyer; Richard L Wahl
Journal:  J Nucl Med       Date:  2002-09       Impact factor: 10.057

View more
  38 in total

1.  Attenuation-emission alignment in cardiac PET/CT based on consistency conditions.

Authors:  Adam M Alessio; Paul E Kinahan; Kyle M Champley; James H Caldwell
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

2.  Simultaneous reconstruction of attenuation and activity in cardiac PET can remove CT misalignment artifacts.

Authors:  L Presotto; E Busnardo; D Perani; L Gianolli; M C Gilardi; V Bettinardi
Journal:  J Nucl Cardiol       Date:  2015-08-15       Impact factor: 5.952

3.  MRI-based nonrigid motion correction in simultaneous PET/MRI.

Authors:  Se Young Chun; Timothy G Reese; Jinsong Ouyang; Bastien Guerin; Ciprian Catana; Xuping Zhu; Nathaniel M Alpert; Georges El Fakhri
Journal:  J Nucl Med       Date:  2012-06-28       Impact factor: 10.057

4.  Respiratory motion handling is mandatory to accomplish the high-resolution PET destiny.

Authors:  Doumit Daou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-09-12       Impact factor: 9.236

Review 5.  Present and future of clinical cardiovascular PET imaging in Europe--a position statement by the European Council of Nuclear Cardiology (ECNC).

Authors:  D Le Guludec; R Lautamäki; J Knuuti; J J Bax; F M Bengel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-06-26       Impact factor: 9.236

Review 6.  Current state of hybrid imaging: attenuation correction and fusion.

Authors:  Jonathon A Nye; Tracy L Faber
Journal:  J Nucl Cardiol       Date:  2011-05-07       Impact factor: 5.952

7.  Interpolated average CT for cardiac PET/CT attenuation correction.

Authors:  Greta S P Mok; Cobie Y T Ho; Bang-Hung Yang; Tung-Hsin Wu
Journal:  J Nucl Cardiol       Date:  2015-05-02       Impact factor: 5.952

8.  Motion correction of respiratory-gated PET images using deep learning based image registration framework.

Authors:  Tiantian Li; Mengxi Zhang; Wenyuan Qi; Evren Asma; Jinyi Qi
Journal:  Phys Med Biol       Date:  2020-07-30       Impact factor: 3.609

9.  Feasibility of myocardial flow reserve prediction without the use of dynamic data from myocardial perfusion positron emission tomography.

Authors:  Hidenobu Hashimoto; Yoshimitsu Fukushima; Shin-Ichiro Kumita; Takeshi Tomiyama; Tomonari Kiriyama
Journal:  Int J Cardiovasc Imaging       Date:  2018-03-19       Impact factor: 2.357

10.  Respiration-averaged CT for attenuation correction in non-small-cell lung cancer.

Authors:  Nai-Ming Cheng; Chih-Teng Yu; Kung-Chu Ho; Yi-Cheng Wu; Yuan-Chang Liu; Chih-Wei Wang; Tzu-Chen Yen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-12-03       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.