Literature DB >> 22737313

Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method.

Rodrigo Tiossi1, Hilmo Barreto Leite Falcão-Filho, Fábio Afrânio de Aguiar, Renata Cristina Silveira Rodrigues, Maria da Gloria Chiarello de Mattos, Ricardo Faria Ribeiro.   

Abstract

PURPOSE: Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks.
MATERIALS AND METHODS: Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The frameworks were cast as one-piece (Group A) and later transversally sectioned through a diagonal axis (Group B) and compared to frameworks that were cast diagonally separated (Group C). All separated frameworks were laser welded. Only one side of the frameworks was screwed.
RESULTS: The results on the tightened side were significantly lower in Group C (6.43 ± 3.24 µm) when compared to Groups A (16.50 ± 7.55 µm) and B (16.27 ± 1.71 µm) (P<.05). On the opposite side, the diagonal section of the one-piece castings for laser welding showed significant improvement in the levels of misfit of the frameworks (Group A, 58.66±14.30 µm; Group B, 39.48±12.03 µm; Group C, 23.13±8.24 µm) (P<.05).
CONCLUSION: Casting diagonally sectioned frameworks lowers the misfit levels. Lower misfit levels for the frameworks can be achieved by diagonally sectioning one-piece frameworks.

Entities:  

Keywords:  Dental implants; Dental soldering; Fixed partial denture; Implant-supported dental prosthesis; Prosthesis fitting; Prosthodontics

Year:  2012        PMID: 22737313      PMCID: PMC3381208          DOI: 10.4047/jap.2012.4.2.89

Source DB:  PubMed          Journal:  J Adv Prosthodont        ISSN: 2005-7806            Impact factor:   1.904


  27 in total

1.  In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion.

Authors:  Ivete Aparecida de Mattias Sartori; Ricardo Faria Ribeiro; Carlos Eduardo Francischone; Maria da Gloria Chiarello de Mattos
Journal:  J Prosthet Dent       Date:  2004-08       Impact factor: 3.426

2.  Influence of irradiation conditions on the deformation of pure titanium frames in laser welding.

Authors:  Michio Shimakura; Satoshi Yamada; Misao Takeuchi; Koki Miura; Joji Ikeyama
Journal:  Dent Mater J       Date:  2009-03       Impact factor: 2.102

3.  An alternative section method for casting and posterior laser welding of metallic frameworks for an implant-supported prosthesis.

Authors:  Fábio Afrânio de Aguiar; Rodrigo Tiossi; Renata Cristina Silveira Rodrigues; Maria de Gloria Chiarello Mattos; Ricardo Faria Ribeiro
Journal:  J Prosthodont       Date:  2008-12-29       Impact factor: 2.752

4.  Modified section method for laser-welding of ill-fitting cp Ti and Ni-Cr alloy one-piece cast implant-supported frameworks.

Authors:  R Tiossi; H Falcão-Filho; F A Aguiar Júnior; R C Rodrigues; M da G Mattos; R F Ribeiro
Journal:  J Oral Rehabil       Date:  2010-02-08       Impact factor: 3.837

5.  Measurement of distortions in fixed partial dentures resulting from degassing.

Authors:  R A Bryant; J I Nicholls
Journal:  J Prosthet Dent       Date:  1979-11       Impact factor: 3.426

6.  In vitro investigation of marginal accuracy of implant-supported screw-retained partial dentures.

Authors:  U Koke; A Wolf; P Lenz; H Gilde
Journal:  J Oral Rehabil       Date:  2004-05       Impact factor: 3.837

7.  Thermal cycling distortion of porcelain fused to metal fixed partial dentures.

Authors:  D Gemalmaz; S Berksun; H N Alkumru; C Kasapoglu
Journal:  J Prosthet Dent       Date:  1998-12       Impact factor: 3.426

8.  Passive fit of frameworks in titanium and palladium-silver alloy submitted the laser welding.

Authors:  S A de Sousa; M A de Arruda Nobilo; G E P Henriques; M F Mesquita
Journal:  J Oral Rehabil       Date:  2008-02       Impact factor: 3.837

9.  Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup.

Authors:  T Jemt
Journal:  Int J Oral Maxillofac Implants       Date:  1991       Impact factor: 2.804

10.  Stress-relieving and porcelain firing cycle influence on marginal fit of commercially pure titanium and titanium-aluminum-vanadium copings.

Authors:  Johnson Campideli Fonseca; Guilherme Elias Pessanha Henriques; Lourenço Correr Sobrinho; Mário Fernando de Góes
Journal:  Dent Mater       Date:  2003-11       Impact factor: 5.304

View more
  2 in total

1.  Evaluation of Marginal Misfit of Metal Frameworks Welded by Gas-Torch, Laser, and Tungsten Inert Gas Methods.

Authors:  Wilson Matsumoto; Paula Pastana Beraldo; Rossana Pereira de Almeida; Ana Paula Macedo; Beatriz Roque Kubata; Takami Hirono Hotta
Journal:  Int J Dent       Date:  2018-10-30

2.  Effect of joining the sectioned implant-supported prosthesis on the peri-implant strain generated in simulated mandibular model.

Authors:  Ipsha Singh; K Chandrasekharan Nair; Jayakar Shetty
Journal:  J Indian Prosthodont Soc       Date:  2017 Oct-Dec
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.