Literature DB >> 20149062

Modified section method for laser-welding of ill-fitting cp Ti and Ni-Cr alloy one-piece cast implant-supported frameworks.

R Tiossi1, H Falcão-Filho, F A Aguiar Júnior, R C Rodrigues, M da G Mattos, R F Ribeiro.   

Abstract

This study aimed to verify the effect of modified section method and laser-welding on the accuracy of fit of ill-fitting commercially pure titanium (cp Ti) and Ni-Cr alloy one-piece cast frameworks. Two sets of similar implant-supported frameworks were constructed. Both groups of six 3-unit implant-supported fixed partial dentures were cast as one-piece [I: Ni-Cr (control) and II: cp Ti] and evaluated for passive fitting in an optical microscope with both screws tightened and with only one screw tightened. All frameworks were then sectioned in the diagonal axis at the pontic region (III: Ni-Cr and IV: cp Ti). Sectioned frameworks were positioned in the matrix (10-Ncm torque) and laser-welded. Passive fitting was evaluated for the second time. Data were submitted to anova and Tukey-Kramer honestly significant difference tests (P < 0.05). With both screws tightened, one-piece cp Ti group II showed significantly higher misfit values (27.57 +/- 5.06 microm) than other groups (I: 11.19 +/- 2.54 microm, III: 12.88 +/- 2.93 microm, IV: 13.77 +/- 1.51 microm) (P < 0.05). In the single-screw-tightened test, with readings on the opposite side to the tightened side, Ni-Cr cast as one-piece (I: 58.66 +/- 14.30 microm) was significantly different from cp Ti group after diagonal section (IV: 27.51 +/- 8.28 microm) (P < 0.05). On the tightened side, no significant differences were found between groups (P > 0.05). Results showed that diagonally sectioning ill-fitting cp Ti frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves passivity levels of the same frameworks when compared to one-piece cast structures.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20149062     DOI: 10.1111/j.1365-2842.2010.02063.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  5 in total

1.  Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method.

Authors:  Rodrigo Tiossi; Hilmo Barreto Leite Falcão-Filho; Fábio Afrânio de Aguiar; Renata Cristina Silveira Rodrigues; Maria da Gloria Chiarello de Mattos; Ricardo Faria Ribeiro
Journal:  J Adv Prosthodont       Date:  2012-05-30       Impact factor: 1.904

2.  Mechanical and interfacial characterization of laser welded Co-Cr alloy with different joint configurations.

Authors:  John Kokolis; Makdad Chakmakchi; Antonios Theocharopoulos; Anthony Prombonas; Spiros Zinelis
Journal:  J Adv Prosthodont       Date:  2015-02-17       Impact factor: 1.904

3.  Evaluation of Marginal Misfit of Metal Frameworks Welded by Gas-Torch, Laser, and Tungsten Inert Gas Methods.

Authors:  Wilson Matsumoto; Paula Pastana Beraldo; Rossana Pereira de Almeida; Ana Paula Macedo; Beatriz Roque Kubata; Takami Hirono Hotta
Journal:  Int J Dent       Date:  2018-10-30

4.  A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment.

Authors:  Pâmela Cândida Aires Ribas de Andrade; Leonardo Flores Luthi; Kyle Stanley; Antônio Carlos Cardoso
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

5.  Effect of joining the sectioned implant-supported prosthesis on the peri-implant strain generated in simulated mandibular model.

Authors:  Ipsha Singh; K Chandrasekharan Nair; Jayakar Shetty
Journal:  J Indian Prosthodont Soc       Date:  2017 Oct-Dec
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.