Thermal cycling distortion of porcelain fused to metal fixed partial dentures.

D Gemalmaz1, S Berksun, H N Alkumru, C Kasapoglu.   

Abstract

STATEMENT OF PROBLEM: The initial fit of porcelain fused to metal restorations deteriorates during the firing cycle of porcelain.
PURPOSE: This study evaluated thermal cycling distortion of 3-unit porcelain fused to metal frameworks at different firing stages.
MATERIAL AND METHODS: A master model was designed to represent the 2 abutments of a 3-unit fixed partial denture replacing a missing mandibular molar. Standard techniques were used to fabricate 10 castings. Half of the copings were cast in a Ni-Cr alloy and the other half in a Pd-Cu alloy. Framework distortion was measured by means of inner fit changes, horizontal linear measurements of the framework length, and vertical fit changes of each retainer. Measurements were made (1) initially, (2) after degassing firing, and (3) after glaze firing. Differences between the firing cycles created distortion values of the retainers in 3 dimensions. Repeated measures ANOVA was used to analyze data statistically.
RESULTS: Measured differences between the 2 firing stages ranged from -47 to 81.7 micrometer. For both alloy groups, retainers showed increase in vertical gap that implied poorer vertical fit after porcelain application. Mean values of inner fit change recorded for porcelain application firing were higher in magnitude than the values of metal-conditioning firing. In addition, no statistically significant differences were found among alloy types.
CONCLUSIONS: A 3-dimensional distortion was observed both in Pd-Cu and Ni-Cr frameworks during porcelain firing cycle. The distortion seen after porcelain application firing was significantly greater than that seen after metal-conditioning firing. This result can be attributed to these factors, contamination of porcelain to the inner surface of metal coping and reduction in resilience of metal.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9830069     DOI: 10.1016/s0022-3913(98)70051-4

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method.

Authors:  Rodrigo Tiossi; Hilmo Barreto Leite Falcão-Filho; Fábio Afrânio de Aguiar; Renata Cristina Silveira Rodrigues; Maria da Gloria Chiarello de Mattos; Ricardo Faria Ribeiro
Journal:  J Adv Prosthodont       Date:  2012-05-30       Impact factor: 1.904

2.  Effect of firing cycle and surface finishing on the sag resistance of long-span metal ceramic framework using base metal alloys-an in vitro study.

Authors:  Poonam Prakash; Dsj D'Souza; Manjit Kumar; M Viswambaran
Journal:  Med J Armed Forces India       Date:  2012-04-21

3.  Comparative assessment of marginal accuracy of grade II titanium and Ni-Cr alloy before and after ceramic firing: An in vitro study.

Authors:  Abhijit Patil; Kishan Singh; Sukant Sahoo; Suraj Suvarna; Prince Kumar; Anupam Singh
Journal:  Eur J Dent       Date:  2013-07

4.  Full Arch All-on-4 Fixed Implant-Supported Prostheses with 8.5 Years of Follow-Up: A Case Report.

Authors:  Hakimeh Siadat; Amirreza Rokn; Elaheh Beyabanaki
Journal:  J Dent (Tehran)       Date:  2018-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.