Literature DB >> 12901996

Stress-relieving and porcelain firing cycle influence on marginal fit of commercially pure titanium and titanium-aluminum-vanadium copings.

Johnson Campideli Fonseca1, Guilherme Elias Pessanha Henriques, Lourenço Correr Sobrinho, Mário Fernando de Góes.   

Abstract

OBJECTIVES: This study evaluated: (1) the marginal fit of copings fabricated from commercially pure titanium (cp Ti) and titanium-aluminum-vanadium alloy (Ti-6Al-4V) after each firing cycle for a recommended porcelain; and (2) the effectiveness of a stress-relieving treatment on the fit. The results were compared with copings made with Pd-Ag alloy submitted to the recommended porcelain firing protocol.
METHODS: Bovine teeth were machined for metal-ceramic crowns and die casts were obtained for waxing patterns. The firing cycle of titanium porcelain was performed on cp Ti and Ti-6Al-4V copings obtained using the Rematitan System. A stress-relieving treatment (cp Ti treated and Ti-6Al-4V treated groups) was performed on original invested castings at the first porcelain firing temperature (800 degrees C). Fit (microm) was measured in the 'as cast' condition and after each porcelain firing cycle with a traveling microscope. The values were compared using the analysis of variance and Tukey's test (P<0.05), the Pd-Ag group was compared to titanium groups using Dunnett's test (P<0.05).
RESULTS: The marginal fit values in the as-cast condition (initial) were 84.43 microm for Ti-6Al-4V not treated, 76.35 microm for Ti-6Al-4V treated, 86.09 microm for cp Ti not treated, 97.66 microm for cp Ti treated and 58.11 microm for Pd-Ag group. The Ti-6Al-4V, cp Ti, and Pd-Ag groups exhibit significant differences in marginal fit values when the as-cast condition (initial) was compared with those after the recommended porcelain firing protocol (by Tukey's test at 5% probability level). No significant differences were observed between stress-relieving treated and not treated groups.Significance. The firing cycles used for porcelain build-up may worsen the fit of titanium copings to values that suggest no inferences to the detriment of clinical applications.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12901996     DOI: 10.1016/s0109-5641(03)00014-9

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  9 in total

1.  Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method.

Authors:  Rodrigo Tiossi; Hilmo Barreto Leite Falcão-Filho; Fábio Afrânio de Aguiar; Renata Cristina Silveira Rodrigues; Maria da Gloria Chiarello de Mattos; Ricardo Faria Ribeiro
Journal:  J Adv Prosthodont       Date:  2012-05-30       Impact factor: 1.904

2.  Marginal and internal fit of nano-composite CAD/CAM restorations.

Authors:  So-Hyun Park; Yeon-Jee Yoo; Yoo-Jin Shin; Byeong-Hoon Cho; Seung-Ho Baek
Journal:  Restor Dent Endod       Date:  2016-01-19

3.  Evaluation of Mechanical Properties and Marginal Fit of Crowns Fabricated Using Commercially Pure Titanium and FUS-Invest.

Authors:  Jinshuang Wu; Xianli Wang; Helin Xing; Tianwen Guo; Chaofang Dong; Sefei Yang
Journal:  Biomed Res Int       Date:  2017-08-23       Impact factor: 3.411

Review 4.  A systematic review on the accuracy of zirconia crowns and fixed dental prostheses.

Authors:  Per Svanborg
Journal:  Biomater Investig Dent       Date:  2020-01-07

5.  Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and three-dimensional replica techniques.

Authors:  Ki-Baek Kim; Jae-Hong Kim; Woong-Chul Kim; Hae-Young Kim; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

6.  Marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions.

Authors:  Per Svanborg; Henrik Skjerven; Pablo Carlsson; Alf Eliasson; Stig Karlsson; Anders Ortorp
Journal:  Int J Dent       Date:  2014-03-03

7.  Fit of cobalt-chromium implant frameworks before and after ceramic veneering in comparison with CNC-milled titanium frameworks.

Authors:  Per Svanborg; Victoria Stenport; Alf Eliasson
Journal:  Clin Exp Dent Res       Date:  2015-10-26

8.  Evaluation of marginal adaptation of Co-Cr-Mo metal crowns fabricated by traditional method and computer-aided technologies.

Authors:  Hao-Sheng Chang; Yao-Te Peng; Wei-Lin Hung; Ming-Lun Hsu
Journal:  J Dent Sci       Date:  2019-03-25       Impact factor: 2.080

Review 9.  A systematic review on the accuracy of manufacturing techniques for cobalt chromium fixed dental prostheses.

Authors:  Per Svanborg; Lars Hjalmarsson
Journal:  Biomater Investig Dent       Date:  2020-01-20