Literature DB >> 15295321

In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion.

Ivete Aparecida de Mattias Sartori1, Ricardo Faria Ribeiro, Carlos Eduardo Francischone, Maria da Gloria Chiarello de Mattos.   

Abstract

STATEMENT OF PROBLEM: For implant-supported prostheses, passive fit is critical for the success of rehabilitation, especially when alternative materials are used.
PURPOSE: The purpose of this study was to compare interfacial fit of implant-supported prostheses cast in titanium to those cast in gold alloy.
MATERIAL AND METHODS: Five 3-unit fixed partial dentures were fabricated in gold alloy (Degudent U) as 1-piece castings, and 5 others were similarly cast in commercially pure titanium (Grade 1). The interfacial gaps between the prostheses and the abutments were evaluated with an optical microscope, before and after electroerosion. Readings were made with both screws tightened (10 N.cm torque), and with only 1 side tightened, so as to also evaluate the passive fit of the prostheses. Data were compared statistically by 2-way analysis of variance and the post hoc Tukey multiple range test (alpha=.05).
RESULTS: Before electroerosion, the interfacial gaps for the 1-piece prostheses were significantly smaller (P<.001) in the gold alloy group when the screws were tightened (Au=12.6 +/- 3.0 microm, compared to Ti=30.1 +/- 6.4 microm). When the side opposite the tightened side was analyzed, there was no significant difference between the gold alloy and titanium groups (Au=69.2 +/- 24.9 microm and Ti=94.2 +/- 39.6 microm). The electroerosion procedure significantly (P<.001) reduced the gaps at the interfaces for both groups under all conditions. Comparison between groups after electroerosion did not present significant differences when the side opposite the tightened side was analyzed, but the gold alloy group showed better fit when the tightened side was analyzed (12.8 +/- 1.4 microm for gold alloy; 29.6 +/- 4.4 microm for titanium) and when both screws were tightened (5.4 +/- 2.3 microm for gold alloy; 16.1 +/- 5.5 microm for titanium).
CONCLUSIONS: Cast titanium prostheses, despite showing larger interfacial gaps between the prosthesis and abutment than those obtained with gold alloy, had improved fit after being subjected to electroerosion.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15295321     DOI: 10.1016/j.prosdent.2004.04.001

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method.

Authors:  Rodrigo Tiossi; Hilmo Barreto Leite Falcão-Filho; Fábio Afrânio de Aguiar; Renata Cristina Silveira Rodrigues; Maria da Gloria Chiarello de Mattos; Ricardo Faria Ribeiro
Journal:  J Adv Prosthodont       Date:  2012-05-30       Impact factor: 1.904

2.  Influence of prosthetic screw material on joint stability in passive and non-passive implant-supported dentures.

Authors:  Aloísio Oro Spazzin; Guilherme Elias Pessanha Henriques; Mauro Antônio de Arruda Nóbilo; Rafael Leonardo Xediek Consani; Lourenço Correr-Sobrinho; Marcelo Ferraz Mesquita
Journal:  Open Dent J       Date:  2009-12-30

3.  Multitechnique characterization of CPTi surfaces after electro discharge machining (EDM).

Authors:  Spiros Zinelis; Youssef S Al Jabbari; Andrew Thomas; Nick Silikas; George Eliades
Journal:  Clin Oral Investig       Date:  2013-03-17       Impact factor: 3.573

4.  A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment.

Authors:  Pâmela Cândida Aires Ribas de Andrade; Leonardo Flores Luthi; Kyle Stanley; Antônio Carlos Cardoso
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.